    Supply voltage 24 v dc yes permissible range, lower limit (dc) 20.4 v permissible range, upper limit (dc) 28.8 v load voltage l+ rated value (dc) 24 v permissible range, lower limit (dc) 20.4 v....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 13 Years
    • building Nature of Business Exporter
    • Year of Establishment 2000

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Supply voltage
    24 v dc yes
    permissible range, lower limit (dc) 20.4 v
    permissible range, upper limit (dc) 28.8 v
    load voltage l+
    rated value (dc) 24 v
    permissible range, lower limit (dc) 20.4 v
    permissible range, upper limit (dc) 28.8 v
    input current
    inrush current, max. 12 a; at 28.8 v
    from supply voltage l+, max. 900 ma; 120 to 900 ma, output current for expansion modules (dc 5 v) 660 ma
    encoder supply
    24 v encoder supply
    24 v yes; permissible range: 15.4 to 28.8 v
    short-circuit protection yes; electronic at 280 ma
    output current, max. 280 ma
    backup battery
    battery operation
    backup time, max. 100 h; (min. 70 h at 40 °c); 200 days (typ.) with optional battery module
    memory
    number of memory modules (optional) 1; pluggable memory module, content identical with integral eeprom; can additionally store recipes, data logs and other files
    data and program memory
    data memory, max. 10 kbyte
    program memory, max. 16 kbyte; 12 kb with active run-time edit
    backup
    present yes; program: entire program maintenance-free on integral eeprom, programmable via cpu; data: entire db 1 loaded from pgpc maintenance-free on integral eeprom, current values of db 1 in ram, retentive memory bits, timers, counters, etc. Maintenance-free via high-performance capacitor; optional battery for long-term buffering
    cpu processing times
    for bit operations, max. 0.22 µs
    counters, timers and their retentivity
    s7 counter
    number 256
    of which retentive with battery
    adjustable yes; via high-performance capacitor or battery
    lower limit 1
    upper limit 256
    counting range
    lower limit 0
    upper limit 32767
    s7 times
    number 256
    of which retentive with battery
    adjustable yes; via high-performance capacitor or battery
    upper limit 64
    time range
    lower limit 1 ms
    upper limit 54 min; 4 timers: 1 ms to 30 s; 16 timers: 10 ms to 5 min; 236 timers: 100 ms to 54 min
    data areas and their retentivity
    flag
    number, max. 32 byte
    retentivity available yes; m 0.0 to m 31.7
    of which retentive with battery 0 to 255, via high-performance capacitor or battery, adjustable
    of which retentive without battery 0 to 112 in eeprom, adjustable
    hardware configuration
    expansion devices, max. 7; only expansion modules of the s7-22x series can be used. Due to the limited output current, the use of expansion modules may be limited.
    connectable programming devicespcs simatic pgpc, standard pc
    expansion modules
    analog inputsoutputs, max. 38; 2 onboard inputs and 1 output, also max. 28 inputs and 7 outputs (em) or max. 0 inputs and 14 outputs (em)
    digital inputsoutputs, max. 168; max. 94 inputs and 74 outputs (cpu + em)
    as-interface inputsoutputs max. 62; as-interface ab slaves (cp 243-2)
    digital inputs
    numberbinary inputs 14
    mp-reading yes; optionally, per group
    input voltage
    rated value, dc 24 v
    for signal "0" 0 to 5 v; 0 to 1 v (i 0.3 to I 0.5)
    for signal "1" min. 15 v; min. 4 v (i 0.3 to I 0.5)
    input current
    for signal "1", typ. 2.5 ma; 8 ma for i0.3 to i0.5
    input delay (for rated value of input voltage)
    for standard inputs
    parameterizable yes; all
    at "0" to "1", min. 0.2 ms
    at "0" to "1", max. 12.8 ms
    for interrupt inputs
    parameterizable yes; I 0.0 to I 0.3
    for countertechnological functions
    parameterizable yes; (e0.0 to e1.5) up to 200 khz
    cable length
    cable length, shielded, max. 500 m; standard input: 500 m, high-speed counters: 50 m
    cable length unshielded, max. 300 m; not for high-speed signals
    digital outputs
    numberbinary outputs 10; transistor
    functionalityshort-circuit strength no; to be provided externally
    limitation of inductive shutdown voltage to 1 w
    switching capacity of the outputs
    with resistive load, max. 0.75 a
    on lamp load, max. 5 w
    output voltage
    for signal "1", min. L+ (-0.4 v (5 v 20.4 v for a 0.0 to a 0.4; 20.4 v a 0.5 to a1.1))
    output current
    for signal "1" rated value 750 ma
    for signal "0" residual current, max. 10 µa
    output delay with resistive load
    0 to "1", max. 15 µs; of the standard outputs, max. (q0.2 to q1.1) 15 µs; of the pulse outputs, max. (q0.0 to q0.1) 0.5 µs
    1 to "0", max. 130 µs; of the standard outputs, max. (q0.2 to q1.1) 130 µs; of the pulse outputs, max. (q0.0 to q0.1) 1.5 µs
    parallel switching of 2 outputs
    for increased power yes
    switching frequency
    of the pulse outputs, with resistive load, max. 100 khz; q0.0 to q0.1
    aggregate current of outputs (per group)
    all mounting positions
    up to 40 °c, max. 3.75 a
    horizontal installation
    up to 55 °c, max. 3.75 a
    cable length
    cable length, shielded, max. 500 m
    cable length unshielded, max. 150 m
    analog inputs
    number of analog potentiometers 2; analog potentiometer; resolution 8 bit
    encoder
    connectable encoders
    2-wire sensor yes
    permissible quiescent current (2-wire sensor), max. 1 ma
    1st interface
    type of interface integrated rs 485 interface
    physics rs 485
    functionality
    mpi yes; as mpi slave for data exchange with mpi masters (s7-300s7-400 cpus, ops, tds, push button panels); s7-200-internal cpucpu communication is possible in the mpi network with restrictions; transmission rates: 19.2187.5 kbits
    ppi yes; with ppi protocol for program functions, hmi functions (td 200, op), s7-200-internal cpucpu communication ; transmission rates 9.619.2187.5 kbits
    serial data exchange yes; as freely programmable interface with interrupt facility for serial data exchange with third-party devices with ascii protocol transfer rates: 1.2 2.4 4.8 9.6 19.2 38.4 57.6 115.2 kbits; the pcppi cable can also be used as rs232rs485 converter
    mpi
    transmission rate, max. 187.5 kbits
    transmission rate, min. 19.2 kbits
    2nd interface
    type of interface integrated rs 485 interface
    physics rs 485
    functionality
    mpi yes; as mpi slave for data exchange with mpi masters (s7-300s7-400 cpus, ops, tds, push button panels); s7-200-internal cpucpu communication is possible in the mpi network with restrictions; transmission rates: 19.2187.5 kbits
    ppi yes; with ppi protocol for program functions, hmi functions (td 200, op), s7-200-internal cpucpu communication ; transmission rates 9.619.2187.5 kbits
    serial data exchange yes; as freely programmable interface with interrupt facility for serial data exchange with third-party devices with ascii protocol transfer rates: 1.2 2.4 4.8 9.6 19.2 38.4 57.6 115.2 kbits; the pcppi cable can also be used as rs232rs485 converter
    mpi
    transmission rate, max. 187.5 kbits
    transmission rates, min. 19.2 kbits
    integrated functions
    number of counters 6; high-speed counters (2 to 200 khz and 4 to 30 khz), 32 bits (incl. Sign), can be used as updown counters or for connecting incremental encoders with 2 pulse trains offset by 90° (max. 1 to 100 khz and 3 to 20 khz (ab counters)); parameterizable enable and reset input; interrupt facilities (incl. Call of subroutine with any content) when the setpoint is reached; reversal in counting direction, etc.
    counter frequency (counter) max. 200 khz
    number of alarm inputs 4; 4 rising edges andor 4 falling edges
    number of pulse outputs 2; high-speed outputs, 20 khz, with interrupt option; pulse-width and frequency modulation option
    limit frequency (pulse) 20 khz
    galvanic isolation
    galvanic isolation digital inputs
    between the channels yes
    between the channels, in groups of 6 and 8
    galvanic isolation digital outputs
    between the channels yes; optocoupler
    between the channels, in groups of 5
    permissible potential difference
    between different circuits 500 v dc between 24 v dc and 5 v dc
    ambient conditions
    environmental conditions for further environmental conditions, see "automation system s7-200, system manual"
    operating temperature
    vertical installation, min. 0 °c
    vertical installation, max. 45 °c
    horizontal installation, min. 0 °c
    horizontal installation, max. 55 °c
    air pressure
    permissible range, min. 860 hpa
    permissible range, max. 1080 hpa
    relative humidity
    operation, min. 5 %
    operation, max. 95 %; rh class 2 in accordance with iec 1131-2
    degree and class of protection
    ip20 yes
    configuration
    programming
    programming language
    lad yes
    fbd yes
    stl yes
    command set bit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, transmissions instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions, integer maths, floating-point math instructions, numerical functions
    program processing free cycle (ob 1), interrupt-controller, time-controlled (1 to 255 ms)
    program organization 1 ob, 1 db, 1 sdb subroutines withwithout parameter transfer
    number of subroutines, max. 64
    know-how protection
    user program protectionpassword protection yes; 3-stage password protection
    connection method
    plug-in io terminals yes
    dimensions
    width 140 mm
    height 80 mm
    depth 62 mm
    weight
    weight, approx. 390 g


    Additional Information

    • Payment Terms T/TWestern Union
    • Port of DispatchShenzhen
    • Packaging Details100% Siemens Original and New. Standard Air Conditioning Packing
    • Delivery TimeIn Stock
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Siemens - (6es7214-2ad23-0xb0cpu224xp, DC PS, 14di DC/10do DC/2ai/1ao DC Power Supply)?

    Quantity
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice