Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Spectrapak 309 Cooling Water Test Kit

Listing ID #2033619

  • Supply Type Supplier
Preferred Buyer From : India only

General description cooling water test kit, parameters; nitrite, chloride & ph test recommended to maintain cooling water within the prescribed limits. Nitrite - recommended limits can be in the....
View More Details
Send Enquiry

Company Information

  • Member Since 15 Years
  • Nature of Business Retailer
  • Year of Establishment 2007

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

General description
cooling water test kit, parameters; nitrite, chloride & ph
test recommended to maintain cooling water within the prescribed limits.
Nitrite - recommended limits can be in the range of 700-2400 ppm as no2. Please refer to the inhibitor product data sheet for product specific control limits. The nitrite concentration should be maintained within the above recommended limits to effectively inhibit any corrosive or scaling action within a closed cooling system. Too high a concentration should be avoided to minimize the cost to maintain the system. Insufficient dosage can set up a condition where accelerated corrosion can occur in areas which become unprotected.
Ph - recommended limits 8.3-10. The effectiveness of a corrosion inhibitor is restricted to within a certain ph range. Treatment ensures that this ph range is observed when the nitrite level is sufficiently maintained to prevent corrosion.
Chlorides - recommended limit max. 50 ppm. The chloride value of the cooling water should be kept as low as possible, any increase in value whether sudden or gradual, will be an indication of sea water contamination. Check with engine manufacturer for other specified limits. If the chloride level exceeds 50 ppm, the possibility of corrosion in the system increases because chlorides have a negative effect on the passivation film created by nitrites. Therefore, until corrective action has succeeded in bringing the chloride level back down below 50 ppm, the nitrite level should be kept close to the upper limit (2400 ppm).


Additional Information

  • Payment Terms L/CT/T
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Spectrapak 309 Cooling Water Test Kit?

Quantity
Seller Contact Details
  • Seller M S Exporters & Trading Co.
  • Address Kunnamkulam, Thrissur, Kerala
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Spectrapak 309 Cooling Water Test Kit at Best Price in Thrissur - ID: 2033619
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Spectrapak 309 Cooling Water Test Kit

Listing ID #2033619

  • Supply Type Supplier
Preferred Buyer From : India only

General description cooling water test kit, parameters; nitrite, chloride & ph test recommended to maintain cooling water within the prescribed limits. Nitrite - recommended limits can be in the....
View More Details
Send Enquiry

Company Information

  • Member Since 15 Years
  • Nature of Business Retailer
  • Year of Establishment 2007

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

General description
cooling water test kit, parameters; nitrite, chloride & ph
test recommended to maintain cooling water within the prescribed limits.
Nitrite - recommended limits can be in the range of 700-2400 ppm as no2. Please refer to the inhibitor product data sheet for product specific control limits. The nitrite concentration should be maintained within the above recommended limits to effectively inhibit any corrosive or scaling action within a closed cooling system. Too high a concentration should be avoided to minimize the cost to maintain the system. Insufficient dosage can set up a condition where accelerated corrosion can occur in areas which become unprotected.
Ph - recommended limits 8.3-10. The effectiveness of a corrosion inhibitor is restricted to within a certain ph range. Treatment ensures that this ph range is observed when the nitrite level is sufficiently maintained to prevent corrosion.
Chlorides - recommended limit max. 50 ppm. The chloride value of the cooling water should be kept as low as possible, any increase in value whether sudden or gradual, will be an indication of sea water contamination. Check with engine manufacturer for other specified limits. If the chloride level exceeds 50 ppm, the possibility of corrosion in the system increases because chlorides have a negative effect on the passivation film created by nitrites. Therefore, until corrective action has succeeded in bringing the chloride level back down below 50 ppm, the nitrite level should be kept close to the upper limit (2400 ppm).


Additional Information

  • Payment Terms L/CT/T
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Spectrapak 309 Cooling Water Test Kit?

Quantity
Seller Contact Details
  • Seller M S Exporters & Trading Co.
  • Address Kunnamkulam, Thrissur, Kerala
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice