Company Information
Ask for more detail from the seller
Contact SupplierzDesign:
Split tee will be designed base on ANSI / ASME, with design factor 0.4, 0.5 and 0.72. All mechanical calculation for pressure parts under internal pressure or external forces and fabrication drawings which prepared base on Client’s Technical Specifications will be prepared and forwarded to client for approval. Split Tees are available in a broad range of material types and grades on size and reduced branch outlets Split Tee Fittings available designed in accordance with ANSI / ASME B31.8 , B31.1 , B31Split tee will be designed base on ANSI / ASME, with design factor 0.4, 0.5 and 0.72. All mechanical calculation for pressure parts under internal pressure or external forces and fabrication drawings which prepared base on Client’s Technical Specifications will be prepared and forwarded to client for approval. Split Tees are available in a broad range of material types and grades on size and reduced branch outlets Split Tee Fittings available designed in accordance with ANSI / ASME B31.8 , B31.1 , B31.3, and B31.4
Hot Tap Split Tees are available for pipe sizes from 2” – 48” and are available in ANSI class 150 to ANSI class 2500.
FEATURE CODE :
Compatible with existing hot tapping/plugging equipment
Can be utilized for either hot tapping or line stopping
Split tee fittings eliminate alignment problems
There is no potential for weld to penetrate the tapping area
Allows for maximum hot tap size
Size-on-size fittings normally are available off-the-shelf
Full range of reducing branch sizes available
Greater wall thickness
Higher allowable stresses
More reinforcement area
Design: ANSI B31.1, B31.3, ANSI B31.4 & B31.8 ASME Sec. VIII Div.1 & 2
Fabrication: ASME Sec. VIII Div.1
Welding: ASME Sec. IX • NDT : ASME Sec. V.3, and B31.4
Hot Tap Split Tees are available for pipe sizes from 2” – 48” and are available in ANSI class 150 to ANSI class 2500.
FEATURE CODE :
Compatible with existing hot tapping/plugging equipment
Can be utilized for either hot tapping or line stopping
Split tee fittings eliminate alignment problems
There is no potential for weld to penetrate the tapping area
Allows for maximum hot tap size
Size-on-size fittings normally are available off-the-shelf
Full range of reducing branch sizes available
Greater wall thickness
Higher allowable stresses
More reinforcement area
Design: ANSI B31.1, B31.3, ANSI B31.4 & B31.8 ASME Sec. VIII Div.1 & 2
Fabrication: ASME Sec. VIII Div.1
Welding: ASME Sec. IX • NDT : ASME Sec. V