Company Information
Ask for more detail from the seller
Contact SupplierOperation of Timer based Direct ON Sump pump controller for sump tank and OH tank
·        Fully automatic water level controller connecting sump tank and over head tank maintaining full OH tank as long as water available in the sump
·        1 sensor will be put at OH tank at 90% (High) just below overflow level
·        2 more sensors will be put in sump tank at 10 % just above suction head called low  and at 20% called high levels
·        Pump starts  in timer mode when water is available above 20% in the  sump and OH tank is not Full. Pump runs for the preset ON time OR stops when water reaches Full before preset ON time.
·        Pump goes to OFF for the preset OFF time
·        Pump also stops if water falls below low sensor in the sump as preventive dry run protection.
·        Pump does not start after preset OFF time if water is not above 2 sensors in the sump
·        Pump will not start if any of the 3 sensor wires is broken
·        No airlock or dry RUN since pump stops before water falls below suction
·        It comes with Micro controller Technology, maintenance free magnetic sensors, FR4 doubled sided 1.6mm PCB with green mask and 70 micron thick copper tracks.
·        12 months warranty, direct from manufacturer including controller and sensors
Â