Listing ID #870017
Company Information
Ask for more detail from the seller
Contact SupplierWe offer Powerful pre Surgical Instrument Cleaner to the customers. Snell Surgizyme is a unique combination of enzymes which effectively remove blood, tissue, mucous and other protein rich body fluids, from stainless steel, tungstencarbide, aluminum, brass, glass, plastic materials, delicate micro surgical instruments, flexible and rigid scopes.
Snell Surgizyme is use as pre soak surgical instrument and scope cleaner
Snell Surgizyme immediately works to break down blood, fat and protein and saves reprocessing time by initiating the pre – cleaning process. For most application there is no need to add further cleaning ingredients for pre soaking or manual cleaning.
Snell surizyme saves time, lower inventory levels, cuts the cost of consumables and improves turnaround time.
FAQ's for Snell Surgizyme
Why Snell Surgizyme should be used?
Post-operative instruments are contaminated with human fluid like blood proteins, fasts & starch. Even best cleaner only removes some soils from instruments. That damages instruments and also remains human soil which is best source for bacterial growth which leads to post operative infection. Enzymes in snell surgizyme penetrate to joints and remove human fluid. Thus it minimizes the post-operative infection and increase the life & performance of your instruments.
What is snell Surgizyme?
Snell Surgizyme is a low-foam, neutral pH, Triple enzymatic cleaner for surgical instruments and scope.
What are the benefits of Enzymes in Snell Surgizyme?
Instruments use in surgical procedures may be contaminated with blood proteins such as mucose, starch and fat. Enzyme Action is specific.
Protease dissolves blood proteins
Amylase dissolves starch
Lypase dissolves fat
The Enzymes break down blood, starch and fat faster and completely. Thus it reduces the need for manual scrubbing.
What is the Temperature Rang When using snell Surgizyme?
Snel Surgizyme diluted and used at room temperature (25º C to 45º C) but for faster cleaning result use warm water at (45º C to 55ºC)
Excessive hot water will make protein load adhere to instruments and will cause enzymes to degrade before completing digestion and thus high temperature break down enzymes.
What happens if Snell Surgizymes sits out too long? How often it should be discarded?
Enzymes are an organic protein-based material once mixed with water, they will slowly begin to spoil just, as milk or meat would if left out too long. The solution will begin to smell foul, within a day Enzymes break down as they additional organic digest soils. If instruments are highly contaminated the load and depleted enzymes will both contribute to unpleasant odors, so it should be discarded after each use.
Does Snell Surgizyme Harm Instruments?
No, it as neutral pH safe to use on all instruments including lens and lumen instruments. Non corrosive system to prevent damage to metallic surface during the decontamination process when using this product as a pre-soak or holding solution. It is not recommended to soak metallic items over two hours.
Why Perfume is added to Snell Surgizyme?
There are two reasons,
Why Instruments should be washed with the water, Immersing into snell surgizyme solution?
Surgical instruments immersed into snell surgizyme solution, which is reach with the enzyme, to remove enzymes from the surface of instruments it should be wash with plain water before sterilization.
Advantages :
Recommended Uses :
Direction for Use :
Available in : 100ml, 1 liter, 5liter Pack