Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

TCAL 1503/-35 High Precision Dry Block Temperature Calibrator

Listing ID #6916500

  • MOQ 1 Piece
  • Brand NameSANSEL
  • Supply Type Manufacturer
Preferred Buyer From : India, Oman, Panama, Albania, Argentina, Australia, Azerbaijan, Bahrain, Bolivia, Bhutan, Canada, Switzerland, Germany, Ecuador, Georgia, Greece, Hong Kong, Hungary, Indonesia, Israel, Iraq, Morocco, Myanmar, Mexico, Philippines, Qatar, Turkey, Viet Nam, Yemen, Saudi Arabia, Romania, Portugal

SANSEL Model TCAL 1503 series of Dry well Temperature calibrator range from -35 to 1200 °C in four model (TCAL 1503 / -35, TCAL 1503 / 300, TCAL 1503 / 600 & TCAL 1503 / 1200) are high....
View More Details
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Exporter
  • GST No. 33APGPS4066M1ZG

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

SANSEL Model TCAL 1503 series of Dry well Temperature calibrator range from -35 to 1200 °C in four model (TCAL 1503 / -35, TCAL 1503 / 300, TCAL 1503 / 600 & TCAL 1503 / 1200) are high precision, better resolution, stability, fast in heating and cooling. More well dia and depth to calibrate more number of temperature sensor at a time with better uniformity. These models can meet any calibration requirement in laboratories or in on site applications. This models are inbuilt measuring facility of the Thermocouples, RTD, Resistance, millivolt & milliamps to directly read the signals from most of the temperature sensors, indicator with sensor and Transmitter. Temperature range from -35 to 130 °C with high resolution 0.01 °C up to 130 °C. This model is mainly used in all industries, like Pharmaceutical, food, Research & calibration laboratories etc., These models are using 4.3” True colour TFT display with Touch screen, easy to read multi parameter at the same time like, Block temperature, set temperature, measure value, Real time clock with date & time, Control Output %, Stability time & status, Range of the equipment with necessary unit of measurement and three soft touch keys are used for measure configuration, settings, calibration etc.., It has one more advantage of help menu for operating instruction of the equipment via the same screen , Hence no need of Hard copy of Instruction manual.
Features :

  • 4.3 inch True TFT DISPLAY with touch screen
  • Portable & Rugged
  • Range from -35* to 130 °C
  • Resolution 0.01 °C
  • Stability ± 0.02°C
  • Radial Uniformity better than ± 0.05°C
  • Axial Uniformity upto 40mm better than ± 0.2°C
  • UUC measure option provided
  • Stabilization time & status indication provided
  • Inter changeable insert to suit different diameter sensor - up to 30 mm
  • Optional PC Interface with automatic calibration software


Accessories :

  • Basic Instrument
  • Spare fuses
  • Standard well insert – 2nos
  • Well tool
  • Instruction manual
  • Mains card
  • Traceable calibration certificate


Optional :

  • Master Indicator with sensor
  • Additional well insert
  • Carrying case


Specifications

Model TCAL 1503 / -35
Temperature Range -35* to 130 °C * @ 23 °C Ambient
Resolution 0.01 °C
Stability ± 0.02 °C
Radial Uniformity Better than ± 0.05 °C
Axial Uniformity (40mm) ± 0.2 °C at -35 °C
± 0.15 °C at -15 °C
± 0.07 °C at 0 °C
± 0.15 °C at 100 °C
± 0.2 °C at 130 °C
Display 4.3” True colour TFT display with touch screen
Temperature Read out °C / °F (selectable)
Cooling time 25 mins (25 to -35 °C)
15 mins (25 to -30 °C)
65 mins (130 to 25 °C)
Heating time 25 mins (25 to 130 °C)
75 mins (-35 to 130 °C)
52 mins (-35 to 25 °C)
Stabilization time 10 minutes
Well Dimension(dia. x height) 30 x 160 mm
Test sensor immersion depth 130 mm
Standard well holes in mm Insert No. 1 5.1, 6.2, 6.2 & 8.1, Insert No. 2 6.2, 6.2 & 10.2
Measure inputs RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, mV, Ohms
Switch Test Provided
UUC sensor supply output 24V DC ± 10% / 50mA max.
Power supply 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption 500 VA
Overall Dimension in mm 390 x 185 x 356 (L x B x H)(Approx.)
Instrument Weight 16.6 kg(with well insert)(Approx.)








Company Details close-icon

SANSEL INSTRUMENTS AND CONTROLS is a leading organisation that has established itself in the manufacture of Calibrators, Process Control Instruments and Analytical Instruments. And also we are ISO/ IEC17025 Standard Accredited Calibration Laboratory approved by NABL, India, in the field of Thermal, Mechanical, and Electro-Technical Parameters.
Established in the year 2000, we, Sansel Instruments And Controls are a leading manufacturers and service provider for exporters of Calibration Equipments, process control Instrument and Analytical Instruments Offered products range consists of Temperature Calibrator, Humidity Temperature Calibrator, rpm calibrator, pressure calibrator, Data Logger, 51/2 digit process indicator, flow totalizer, temperature controller, humidity temperature indicator, Timer, Counter, Rpm Indicator, Jumbo Process Indicator, controller, Table Top Model PH, TDS, conductivity, ORP Meter, Online Application PH, TDS, conductivity, ORP Indicator, controller and transmitter.These are manufactured under the direction of experts. Apart from this, these products are admired for their long service life, easy to use, strong construction and user-friendly. Additionally we are also ISO/ IEC17025 Standard Accredited Calibration Laboratory approved by NABL, India, in the field of Thermal, Mechanical, and Electro-Technical Parameters offering Calibration Services to our valued clients.
We have incepted a huge infrastructural facility. Our manufacturing facility is loaded with innovative technology-based Automatic Pick & Place soldering machines and high precision Testing and calibration equipments in tune with the quality standards. Moreover, our equipments meets a high level of quality standards. Further, we have established a spacious warehouse that is facilitated with all the necessary tools. Also, our products are packed using supreme quality packing material to protect them from damages during shipping Across The World.
Director\'s Profile
Both contain a coherent argument, supporting evidence/analysis, and a conclusion. Specifically, the contents of a paragraph are as follows: The Topic Sentence serves two functions: first, it functions as the thesis of your paragraph; second, it pushes the thesis of your essay forward and presents an arguable point. The Topic Sentence serves two functions: first, it functions as the thesis of your paragraph; second, it pushes the thesis of your essay forward and presents an arguable point.
Quality Policy
We commit ourselves to Design, Manufacture & Supply of Innovated Quality Products, Strive to Achieve Customer Delight through Excellence in Team Work and Continual Improvement upon the business with effective Quality Management System.

  • Nature of Business Manufacturer / Exporter / Service Provider
  • Number of Employees Below 20
  • Year of Establishment 2000
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for TCAL 1503/-35 High Precision Dry Block Temperature Calibrator?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
TCAL 1503/-35 High Precision Dry Block Temperature Calibrator at Best Price in Chennai
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

TCAL 1503/-35 High Precision Dry Block Temperature Calibrator

Listing ID #6916500

  • MOQ 1 Piece
  • Brand NameSANSEL
  • Supply Type Manufacturer
Preferred Buyer From : All over the world

SANSEL Model TCAL 1503 series of Dry well Temperature calibrator range from -35 to 1200 °C in four model (TCAL 1503 / -35, TCAL 1503 / 300, TCAL 1503 / 600 & TCAL 1503 / 1200) are high....
View More Details
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Exporter
  • GST No. 33APGPS4066M1ZG

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

SANSEL Model TCAL 1503 series of Dry well Temperature calibrator range from -35 to 1200 °C in four model (TCAL 1503 / -35, TCAL 1503 / 300, TCAL 1503 / 600 & TCAL 1503 / 1200) are high precision, better resolution, stability, fast in heating and cooling. More well dia and depth to calibrate more number of temperature sensor at a time with better uniformity. These models can meet any calibration requirement in laboratories or in on site applications. This models are inbuilt measuring facility of the Thermocouples, RTD, Resistance, millivolt & milliamps to directly read the signals from most of the temperature sensors, indicator with sensor and Transmitter. Temperature range from -35 to 130 °C with high resolution 0.01 °C up to 130 °C. This model is mainly used in all industries, like Pharmaceutical, food, Research & calibration laboratories etc., These models are using 4.3” True colour TFT display with Touch screen, easy to read multi parameter at the same time like, Block temperature, set temperature, measure value, Real time clock with date & time, Control Output %, Stability time & status, Range of the equipment with necessary unit of measurement and three soft touch keys are used for measure configuration, settings, calibration etc.., It has one more advantage of help menu for operating instruction of the equipment via the same screen , Hence no need of Hard copy of Instruction manual.
Features :

  • 4.3 inch True TFT DISPLAY with touch screen
  • Portable & Rugged
  • Range from -35* to 130 °C
  • Resolution 0.01 °C
  • Stability ± 0.02°C
  • Radial Uniformity better than ± 0.05°C
  • Axial Uniformity upto 40mm better than ± 0.2°C
  • UUC measure option provided
  • Stabilization time & status indication provided
  • Inter changeable insert to suit different diameter sensor - up to 30 mm
  • Optional PC Interface with automatic calibration software


Accessories :

  • Basic Instrument
  • Spare fuses
  • Standard well insert – 2nos
  • Well tool
  • Instruction manual
  • Mains card
  • Traceable calibration certificate


Optional :

  • Master Indicator with sensor
  • Additional well insert
  • Carrying case


Specifications

Model TCAL 1503 / -35
Temperature Range -35* to 130 °C * @ 23 °C Ambient
Resolution 0.01 °C
Stability ± 0.02 °C
Radial Uniformity Better than ± 0.05 °C
Axial Uniformity (40mm) ± 0.2 °C at -35 °C
± 0.15 °C at -15 °C
± 0.07 °C at 0 °C
± 0.15 °C at 100 °C
± 0.2 °C at 130 °C
Display 4.3” True colour TFT display with touch screen
Temperature Read out °C / °F (selectable)
Cooling time 25 mins (25 to -35 °C)
15 mins (25 to -30 °C)
65 mins (130 to 25 °C)
Heating time 25 mins (25 to 130 °C)
75 mins (-35 to 130 °C)
52 mins (-35 to 25 °C)
Stabilization time 10 minutes
Well Dimension(dia. x height) 30 x 160 mm
Test sensor immersion depth 130 mm
Standard well holes in mm Insert No. 1 5.1, 6.2, 6.2 & 8.1, Insert No. 2 6.2, 6.2 & 10.2
Measure inputs RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, mV, Ohms
Switch Test Provided
UUC sensor supply output 24V DC ± 10% / 50mA max.
Power supply 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption 500 VA
Overall Dimension in mm 390 x 185 x 356 (L x B x H)(Approx.)
Instrument Weight 16.6 kg(with well insert)(Approx.)








Company Details close-icon

SANSEL INSTRUMENTS AND CONTROLS is a leading organisation that has established itself in the manufacture of Calibrators, Process Control Instruments and Analytical Instruments. And also we are ISO/ IEC17025 Standard Accredited Calibration Laboratory approved by NABL, India, in the field of Thermal, Mechanical, and Electro-Technical Parameters.
Established in the year 2000, we, Sansel Instruments And Controls are a leading manufacturers and service provider for exporters of Calibration Equipments, process control Instrument and Analytical Instruments Offered products range consists of Temperature Calibrator, Humidity Temperature Calibrator, rpm calibrator, pressure calibrator, Data Logger, 51/2 digit process indicator, flow totalizer, temperature controller, humidity temperature indicator, Timer, Counter, Rpm Indicator, Jumbo Process Indicator, controller, Table Top Model PH, TDS, conductivity, ORP Meter, Online Application PH, TDS, conductivity, ORP Indicator, controller and transmitter.These are manufactured under the direction of experts. Apart from this, these products are admired for their long service life, easy to use, strong construction and user-friendly. Additionally we are also ISO/ IEC17025 Standard Accredited Calibration Laboratory approved by NABL, India, in the field of Thermal, Mechanical, and Electro-Technical Parameters offering Calibration Services to our valued clients.
We have incepted a huge infrastructural facility. Our manufacturing facility is loaded with innovative technology-based Automatic Pick & Place soldering machines and high precision Testing and calibration equipments in tune with the quality standards. Moreover, our equipments meets a high level of quality standards. Further, we have established a spacious warehouse that is facilitated with all the necessary tools. Also, our products are packed using supreme quality packing material to protect them from damages during shipping Across The World.
Director\'s Profile
Both contain a coherent argument, supporting evidence/analysis, and a conclusion. Specifically, the contents of a paragraph are as follows: The Topic Sentence serves two functions: first, it functions as the thesis of your paragraph; second, it pushes the thesis of your essay forward and presents an arguable point. The Topic Sentence serves two functions: first, it functions as the thesis of your paragraph; second, it pushes the thesis of your essay forward and presents an arguable point.
Quality Policy
We commit ourselves to Design, Manufacture & Supply of Innovated Quality Products, Strive to Achieve Customer Delight through Excellence in Team Work and Continual Improvement upon the business with effective Quality Management System.

  • Nature of Business Manufacturer / Exporter / Service Provider
  • Number of Employees Below 20
  • Year of Establishment 2000
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for TCAL 1503/-35 High Precision Dry Block Temperature Calibrator?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice