    Thermic Fluid Heaters

    • Supply TypeManufacturer
    • Preferred Buyer Location All over the world

    This system is forced circulation fully automatic thermic fluid heater where thermic fluid is circulated in a closed loop through heater and user equipment circuit where the heat is dissipated to....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 14 Years
    • building Nature of Business Manufacturer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    This system is forced circulation fully automatic thermic fluid heater where thermic fluid is circulated in a closed loop through heater and user equipment circuit where the heat is dissipated to process. The same thermic fluid is re-circulated through heater for heating. The thermic fluid heater gives high temperature upto 300 oC using thermic fluid oil at near atmospheric pressure as compared to steam heating which requires 85 Kg/Cm2 pressure.

    FEATURES

     

    MULTIFUEL CONCEPT

    Guaranted output on low grade coal and lignite with GCV upto 3800 Kcal/Kg. Agricultural Wastes such as rice Husk, Bagasse, Groundnut shell, Saw Dust etc.

    HIGHEST EFFICIENCY

    The combustion chamber dimension and grate area are suitably designed for maximum combustion efficiency on low grade fuel. This system is easily accessible and large heating surface of Thermo Energy Systems heater and air pre-heater assures on unmatched efficiency f 76% (on GCV of coal having 5000 Kcal/Kg.)

    LOW POWER CONSUMPTION

    Unique design of Thermo Energy Systems heater ensures lowest power consumption over any other competing system available today.

    ABSOLUTE SAFETY

    External Combustion chamber ensures longer life of heater coil and thermic fluid. No radiation energy is transferred to heater coil in case of power failure ensuring complete safety. Diesel engine driven pump is not required for Fluid tech heater as compared to vertical systems.

    EXTERNAL FURNACE

    Coal/Lignite is burnt in an external furnace which results in an elimination of any possible hazard to the thermic fluid heater coil. A flue by-pass system is attached for the protection against power failure. The entire furnace is provided with steel casing and the combustion chamber is constructed with best quality high heat duty fire bricks and insulation bricks. Mineral wool insulating panels help minimum heat loss.

    THERMIC FLUID HEATER

    Here a nest of concentric helical tube coils is placed within sturdy mild steel shell. The special arrangement of concentric coils ensures optimum heat transfer. The system along with the standard accessories is conveniently mounted on the sturdy steel skid for easy installation.

     

    SAFETY CONTROLES AND INSTRUMENTATION

     Digital Electronic indicator cum controller forward/return temperature for ID fan off.
     Electronic stack temperature controller shuts of the unit in case of abnormally low temperature.
     Electronic low level controller in expansion cum deareated tank shuts off the unit in case of low thermic fluid level in tank.
     Electronic forward high temperature safety controllers shuts off the unit case forward temperature exceeds than minimum recommended temperature.
     Differential pressure switch shuts of in case of abnormal fluid flow conditions.
     Pressure gauge for inlet pressure measurement.
     Pressure gauge for circuit pressure measurement.
     Audio visual alarm for abnormal operating conditions.

     

    OPTIONAL FEATURES

     Coal cum oil firing system to change over from one fuel to another with minimum down time,
     Automatic by-pass damper with electromagnetic or pneumatic device.
     Modulating damper or variable speed drive to control combustion under all operating conditions.

     



     

    ParameterUnitModel
    TFHV-400TFHV-600TFHV-1000TFHV-1500TFHV-2000
    Heat OutputKcal/Hr4,00,0006,00,00010,00,00015,00,00020,00,000
    Max.Fluid Outlet TemperatureoC300
    Max. Head at heater OutletM/c27
    Efficiency on GCVWith APH+%75
    Without APH+%70
    Rated fuel consumptionSteam CoalKg/hr116175290435580
    LigniteKg/hr150226376564752
    Agro-wasteKg/hr174260433650866
    Thermic Fluid Pump MotorKw7.59.3011.018.530
    I.D.Fan MotorKw3.75.59.311.015.0
    Over fire fan motorKw-1.502.203.705.50
    Total LoadKw11.2016.3022.5033.2050.70
    Expansion Tank CapacityLiters800800100010001250
    Overall DimensionsLengthmm460060007500780010000
    Withmm38004000450054006200
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Thermic Fluid Heaters?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice