    Transformer Oil finds extensive usage in power transformers, oil immersed circuit breakers and switchgear. We are counted among the top Manufacturers, Exporters and Suppliers of Transformer Oil from....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 8 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Transformer Oil finds extensive usage in power transformers, oil immersed circuit breakers and switchgear. We are counted among the top Manufacturers, Exporters and Suppliers of Transformer Oil from Delhi, India. Our Transformer Oil is regularly tested at our fully equipped laboratory and is also periodically checked at reputed independent laboratories recognized by the Government. The Transformer Oil that we offer confirms various standards such as IEC -296 Class I, BS 148 Class I, VDEO 370, DIN 57370 : 1978 Class A, IFC 296 Class II, BS 148 Class II, ASTM d 3487 Type I and IS : 335 : 1993. We serve all major consumers like State Electricity Boards Transformer Manufacturers, giant industries and utilities.
    Note : The above data is indicated of recent overage values only. Minor variation which does not affect product performance of quality may be expected in manufacture.

     

    Properties :

    • Good dielectric properties resulting in minimum power loss.

    • High resistively gives better insulation values between windings.

    • High flash point resulting in low evaporation losses due to high thermal stability.

    • Excellent interfacial tension for quick water separation.

    • Proven resistance to electrical stresses.

    • High electrical strength.

    • Low viscosity improves cooling.

    • Remarkably low sludge &; acidity formation in both ageing & oxidation tests.
    • Gives longer life to oil and equipment during storage and service.

     

    Applications :

    • Power zone Transformer oils are widely used in Transformers, oil immersed circuit breakers and switchgears.
    • Power zone transformer oils are widely used in special transformers designed to operate at elevated temperatures and in low maintenance free transformers designed to operate for longer periods.

     

    Supply : Transformer oils are available in a variety of packing options to suit customer needs, ranging from Cans, Drums, Tank Trucks, ISO Tank Containers and Flexi Bags, Bulk transportation is done via a wholly owned dedicated fleet of stainless steel and epiocated tankers to ensure prompt delivery and reliability.


    Technical Specifications

    CharacteristicsTest MethodsAs Per IS:335

    As Amended

    Powerzone New Insulating Oil
    MinMax
    AppearanceA Representative sample and transparent and free from suspended matter or sedimentThe oil shall be clear yellow in color and and free from suspended matter or sediment Clear, transporent, light
    Density @ 29.5 0C, g/c, m3IS : 1448 (P-16)-0.890.81g/cm3
    Kinematic Viscosity at 270C , cSTIS : 1448 (P-16) -2712.4 cST
    Interfacial tension N/m at 27 0CIS : 61040.04-0.051 N/M
    Flash point PMCC, 0CIS : 1448 (P-21)140-160 0C
    Pour Point, 0CIS : 1448 (P-10)--6-120C

    Neutralisation Value

       Total acidity,                mgKOH/gm( Max)

      After filtration

    IS : 1448 (P-2)

     

     

     

    -

    -

     

    0.03

    Nil

     

    0.0009mg/KOH/g

    Nil

    Corrosive SulphurAnnex BNon Corrosive

    Electrical Strength (Breakdown Voltage)KV(rms)

       New Unfiltered Oil

       After filtration

    IS : 6792

     

     

    30

    60

     

     

    -

    -

     

     

    65

    75

    Dielectric Dissipation Factor,

    (Tan deelta) at 90 0C

    IS : 6262-0.020.0003

    Specific Resistance(resistivity) Ohm-cm

       At 90 0C

       At 27 0C

    IS : 6103

     

     

    -

    -

     

     

    -

    -

     

     

    300x1012

    3200x1012

    Oxidation Stability 164 Hours @1000C

      a) Neutralisation Value after oxidation, mgKOH/gm

      b) Total Sludge, wt% after oxidation

    Annex C

     

     

    -

    -

     

     

    0.40

    0.10

     

     

    0.091

    0.0087

    Accelerated Ageing test 96 hrs @ 1000C

    (Open Bealer Method)

      

          a) Sp. Resistance (resistivity)ohm-cm @ 270C

           b) Sp. Resistance (resistivity)ohm-cm @ 900C

           c) Dielectric Dessipation Factor,@ 90 0C

           d) Total acidity, mg/KOH/gm

           e) Total Sludge, %wt

    IS : 12177

     

    IS : 6103

    IS : 6103

    IS : 6262

    IS : 1448(P-2)

    Annex A of IS 12177

    -

     

    -

    -

    -

    -

    -

    2.5x1012

    2.5x1012

    0.20

    0.05

    0.05

    61.41x1012

    6.87x1012

    0.034

    0.035

    0.006

    Presence of oxidation inhibitor %wtIS : 13631The oil shall not contain antioxidant additivesNot present
    Water content ppm MaxIS : 13567-50ppm15ppm
    S.K. Value, % (max)Annex D, IS : 3358 Max 1

     

    Our Product Confirms (IS : 335 : 1993)

    IEC -296 Class I, bs 148 Class I, VDEO 370, DIN 57370 : 1978 Class A, IFC 296 Class II, BS 148 Class II, astm d 3487 Type I

    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Transformer Oil?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice