Class-II Biosafety Cabinet Protection :
Class-II Biosafety Cabinet Key Features :
Class-II Biosafety Cabinet Applications :
Exhaust System with Blower
With an integral and essential exhaust system consisting of a heavy duty and powerful motor blower system, Class II Type B2 biological safety cabinet is able to exhaust 100% potentially contaminated air outside the cabinet & air.
Drain Trough with Valve
The trough at base is easy to clean and for offloading liquid spillage if any.
Upper & Front Cover
Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.
Decontamination By UV Lamp
UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.
Front Window/Sash
Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.
Splash Proof Electric Supply Socket
Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.
Material of Construction
Front Airflow Intake Grid
Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.
Floor Stand and Castor Wheels
Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.
Options
| Model | APS-BSC 2(B2) | APS- BSC 3(B2) | APS- BSC 4(B2) | APS- BSC 5(B2) | APS- BSC 6(B2) |
|---|---|---|---|---|---|
| Internal Dimensions (WxDxH)mm | 600x600x600 | 900x600x600 | 1200x600x600 | 1500x600x600 | 1780x600x600 |
| MOC | Internal Working Chamber : Stainless steel (SS-304) Exterior Cabinet : Cold Rolled Steel Duly Powder Coated or Stainless Steel (SS-304) | ||||
| Pre - Filter | Mounted on aluminium frame, of rating 20 microns | ||||
| Supply / Main Filter | HEPA (Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, Class 10 | ||||
| Exhaust Filter | HEPA (Efficiency 99.97% @0.3 microns to meet air quality ISO Class 4 equivalent to US FED STD 209 E, Class 10 | ||||
| Electrical Socket | Electrical Socket is provided for using small electrical devices | ||||
| Power Supply | 220/230 Volts AC supply | ||||
| Heavy Duty Exhaust System | Standard fitted to the system for 100% exhaust | ||||
| Exhaust Tunnel/Duct (Option) | Available on per running feet basis | ||||
| Sash Lift | Can be lifted and adjusted manually | ||||