Contact SupplierPort size 03 and 06 are available.
.to adjust the pressure, loosen the lock nut and turn the pressure adjustment handle slowly clockwise for higher pressures or anti-clockwise for lower pressure. After adjustments, do not forget to tighten the lock nut.
2. Take care not to neglect connecting the drain pipe to the tank; otherwise not only will the valve fail to operate properly but also the line pressure will rise infinitely. Extend the end of the drain pipe into fluid.
3 .limit the pressure drop between the valve and the accumulator in an accumulator circuit below 10% of the cut-out pressure.
4. Limit the drain pot back pressure below 2% of the cut-out pressure.