    Vapour Absorption Test Rig

    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world

    “Vapour Absorption Refrigerator” earlier known as “Electrolux” refrigerator is a self contained refrigerator working on absorption technology. In the absence of a compressor or pump, the....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 12 Years
    • building Nature of Business Manufacturer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    “Vapour Absorption Refrigerator” earlier known as “Electrolux” refrigerator is a self contained refrigerator working on absorption technology. In the absence of a compressor or pump, the circulation takes place by density difference. The system is pre-charged with three fluids namely water, ammonia and hydrogen. Hydrogen is used as an “inert gas” and does not undergo any phase change and heat transfer processes. Its purpose is to keep the pressure of the system constant. It uses an electrically operated generator, where, the ammonia vapours dissolved in water are separated and pure ammonia vapours enter the condenser. In the condenser, the high pressure vapours reject its latent heat to the surroundings and get liquefied. The liquid ammonia expands through expansion device where its pressure and temperature is reduced and cold low pressure vapour enters the evaporator where it absorbs heat from the space to be cooled and then vaporized ammonia absorbs in water. This strong solution then enters the generator and the cycle repeats.
    PRINCIPLE OF OPERATION
    Electrolux principle works on 3-fluid system. There is solution circulation pump. Total pressure is the same throughout the system. The third fluid remains mainly in the evaporator thus reducing partial pressure of refrigerant to enable it to evaporate at low pressure and hence low temperature.
    The schematic diagram of the Electrolux refrigerator working on NH3-H2O system with H2 as the third fluid is shown in figure. Liquid NH3 evaporates in the evaporator in the pressure of H2.Hydrogen is chosen as it is non –corrosive and insoluble in water.
    A thermosyphon bubble pump is used to lift the weak aqua from the generator to the separator. The discharge tube from the evaporator the generator is extended down below the liquid level in the generator. The bubbles rise and carry slugs of weak NH3-H2O solution into the separator.
    Two U-bends are provided as vapour- locks to prevent H2 from getting into the high side or solution circuit.
    Partial pressure of H2 provides the pressure difference of NH3 between the condenser and evaporator. Accordingly, we have:
    In condenser pure NH3 vapour pressure = Total pressure
    In evaporator NH3 vapour pressure = Total pressure - partial pressure H2
    For example, consider the condenser temperature at 50 0C, and evaporator temperature as -15 0C. The corresponding vapour pressures of NH3 are:
    Condenser, Pk = 20.33bar; Evaporator outlet, Po2 = 2.6bar



    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Vapour Absorption Test Rig?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice