Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Ventilator

Listing ID #3857405

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

VENTILATOR ITEM CODE: OTE-07 Power Line 220 VAC range (220-240 VAC), 0.5 Ampere, 50/60 Hz., external voltage selector switch. Gauge: Use 3-conductor harmonized cord only; up to 49′ use 18 gauge....
View More Details
Send Enquiry

Company Information

  • Member Since 21 Years
  • Nature of Business Retailer
  • Year of Establishment 1966

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

VENTILATOR ITEM CODE: OTE-07

Power Line 220 VAC range (220-240 VAC), 0.5 Ampere, 50/60 Hz., external voltage selector switch. Gauge: Use 3-conductor harmonized cord only; up to 49′ use 18 gauge cord; up to 99′, use 16 gauge cord; up to 200′, use 14 gauge cord. External Battery: 12 VDC, 5 Amperes. Approximately 20 hrs. operation with 75-80 Amp-hour 12 VDC deep-cycle, gel-cell battery. Approximately 10 hrs operation with 35-40 Amp-hour 12 VDC deep-cycle, gel-cell battery. Internal Battery: Approximately 1 hour operation. Type: Volume ventilator. Motor Brushless induction. Pump: Piston, 100 to 2200 ml tidal volume capability. Front Panel Controls: Alarm Silence/Reset: Push button to silence alarms during events or reset after events; used with Battery Test button to read machine operating hours on Patient Pressure meter Battery Test: Push button to show battery charge level on the lower window of Patient Pressure meter. Mode: Rotary switches to set ventilator operating mode: Standby, Assist/Control, SIMV, or Pressure Cycle. Low Alarm: Rotary switch to set limit for Low Pressure alarm: 2 to 32 cmH2O/hPa in increments of 2 cmH2O/hPa High Alarm Limit: Rotary switch to set limit for High Pressure alarm {Assist/Control, SIMV modes} or limit for Pressure Cycle mode: 15 to 90 cmH2O/hPa in increments of 5 cmH2O/hPa Volume: Push-to-turn knob to set volume: continuously adjustable from 100 to 2200 ml. Breath Rate: Rotary switch to set breathing rate: 120 BPM in increments of 1 BPM and 2238 BPM in increments of 2 BPM. Inspiratory Time: Rotary switch to set time for delivery of set volume: 0.5 to 1.0 sec. in increments of 0.1 sec.; 1.2 sec.; and 1.5 to 5.5 sec. in increments of 0.5 sec. Breathing Effort: Push-to-turn knob to set pressure level for detecting breathing effort; continuously adjustable from -10 to +10 cmH2O/hPa Pressure Limit (LP10 Only): Locking knob sets pressure limit level from 15 to 50 cmH2O/hPa or closes off the pressure limit feature. Input Patient Pressure: Port for connection to the proximal pressure line of the patient circuit. Outputs Patient Air: 22 mm tube for connection to the bacteria filter. Exhalation Valve: Port for connection to the exhalation valve of the patient circuit. Indicators Normal Events Patient Pressure Meter: Displays patient pressure, -10 to +100 cmH2O/hPa; also displays battery charge and machine hours of operation when appropriate buttons are pressed. Breathing Effort: Green LED activated by adequate patient breathing effort. Power: LEDs indicate operating power source: green AC Pwr/Batt Charge, amber External Battery, flashing amber Internal Battery. Alarms: Flashing red LEDs: Low pressure /Apnea, Low Power, High Pressure, Setting Error, Power Switchover. Audible Alarms Pulsating Tone: Low Pressure/Apnea, Low Power, High Pressure, Setting Error, Power Switchover. Steady Tone: Loss of microprocessor control. Reminder Tone: Every five minutes when powered by Internal battery, each time accessory printer generates a report. Rear Panel Controls AC Circuit Breaker Internal to the AC Power Switch (1 for ON; 0 for OFF), 1 Ampere Inputs Inlet Filter: Intake for patient air. Screw off cap for filter change. External Battery: Connection for 12 VDC battery. Communications Port Calibration information during service procedure. Outputs Vent: Cooling vent for internal ventilator components Remote Alarm Connection for optional alarm accessories. Communications Port Connector for optional printer


Company Details close-icon

COMPANY PRESENTATION
Blood Bank Equipment by Rajas Enterprises (India) Ambala
Company Presentation – Rajas Enterprises (India), Ambala, India
Slide 1:
Manufacturer & Exporter of Medical Equipment & Instruments
Slide 2:
About Us Established in the year of 1990, ISO 9001 & 14001 Certified Company, Highly reputed client base, Ethical business practice, Superior quality products
Slide 3:
Why Us? R&D facility, Timely delivery, Competitive prices, Customized solutions, Strict quality measures
Slide 4:
Products- Blood Bank & Dental Equipment, E.N.T & Electro Medical Equipment, Hospital Furniture, Utensils & Holloware, Lab Equipment & Laboratory Plasticware, O. T. and Examination Lights
Slide 5:
Blood Bank & Dental Equipment- Blood Bank Refrigerator, Donor Couch, Blood Collection Monitor, Blood Bag Tube Sealer, Plasma Extractor, Dental Chair Hydraulic
Slide 6:
E.N.T & Electro Medical Equipment- ENT Equipment Set, Operating Microscope, Fiber Optic Head Light, Halogen Head Light, Audiometer, Halogen Operation Light
Slide 7:
Hospital Furniture, Utensils & Holloware- ICU Beds, Attendant Bed, Operation & Examination Table, Emergency Recovery Trolley, Kidney Tray Various Size, Solution / Dressing Bowl
Slide 8:
Lab Equipment & Laboratory Plasticware- Hot Air Oven, Incubator, B.O.D Incubator, Centrifuge Machine High Speed, Plastic Cylinders Graduated, Plastic Cylinder
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 20 - 50
  • Year of Establishment 1966
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Ventilator?

Quantity
Seller Contact Details
  • Seller Rajas Enterprises (India)
  • Address Kuldeep Nagar, Ambala, Haryana
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice