Ventilator

Listing ID #4668625

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Power Line 220 VAC range (220-240 VAC), 0.5 Ampere, 50/60 Hz., external voltage selector switch. Gauge: Use 3-conductor harmonized cord only; up to 49′ use 18 gauge cord; up to 99′, use 16....
View More Details
Send Enquiry

Company Information

  • Member Since 7 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Power Line 220 VAC range (220-240 VAC), 0.5 Ampere, 50/60 Hz., external voltage selector switch. Gauge: Use 3-conductor harmonized cord only; up to 49′ use 18 gauge cord; up to 99′, use 16 gauge cord; up to 200′, use 14 gauge cord. External Battery: 12 VDC, 5 Amperes. Approximately 20 hrs. operation with 75-80 Amp-hour 12 VDC deep-cycle, gel-cell battery. Approximately 10 hrs operation with 35-40 Amp-hour 12 VDC deep-cycle, gel-cell battery. Internal Battery: Approximately 1 hour operation. Type: Volume ventilator. Motor Brushless induction. Pump: Piston, 100 to 2200 ml tidal volume capability. Front Panel Controls: Alarm Silence/Reset: Push button to silence alarms during events or reset after events; used with Battery Test button to read machine operating hours on Patient Pressure meter Battery Test: Push button to show battery charge level on the lower window of Patient Pressure meter. Mode: Rotary switches to set ventilator operating mode: Standby, Assist/Control, SIMV, or Pressure Cycle. Low Alarm: Rotary switch to set limit for Low Pressure alarm: 2 to 32 cmH2O/hPa in increments of 2 cmH2O/hPa High Alarm Limit: Rotary switch to set limit for High Pressure alarm {Assist/Control, SIMV modes} or limit for Pressure Cycle mode: 15 to 90 cmH2O/hPa in increments of 5 cmH2O/hPa Volume: Push-to-turn knob to set volume: continuously adjustable from 100 to 2200 ml. Breath Rate: Rotary switch to set breathing rate: 120 BPM in increments of 1 BPM and 2238 BPM in increments of 2 BPM. Inspiratory Time: Rotary switch to set time for delivery of set volume: 0.5 to 1.0 sec. in increments of 0.1 sec.; 1.2 sec.; and 1.5 to 5.5 sec. in increments of 0.5 sec. Breathing Effort: Push-to-turn knob to set pressure level for detecting breathing effort; continuously adjustable from -10 to +10 cmH2O/hPa Pressure Limit (LP10 Only): Locking knob sets pressure limit level from 15 to 50 cmH2O/hPa or closes off the pressure limit feature. Input Patient Pressure: Port for connection to the proximal pressure line of the patient circuit. Outputs Patient Air: 22 mm tube for connection to the bacteria filter. Exhalation Valve: Port for connection to the exhalation valve of the patient circuit. Indicators Normal Events Patient Pressure Meter: Displays patient pressure, -10 to +100 cmH2O/hPa; also displays battery charge and machine hours of operation when appropriate buttons are pressed. Breathing Effort: Green LED activated by adequate patient breathing effort. Power: LEDs indicate operating power source: green AC Pwr/Batt Charge, amber External Battery, flashing amber Internal Battery. Alarms: Flashing red LEDs: Low pressure /Apnea, Low Power, High Pressure, Setting Error, Power Switchover. Audible Alarms Pulsating Tone: Low Pressure/Apnea, Low Power, High Pressure, Setting Error, Power Switchover. Steady Tone: Loss of microprocessor control. Reminder Tone: Every five minutes when powered by Internal battery, each time accessory printer generates a report. Rear Panel Controls AC Circuit Breaker Internal to the AC Power Switch (1 for ON; 0 for OFF), 1 Ampere Inputs Inlet Filter: Intake for patient air. Screw off cap for filter change. External Battery: Connection for 12 VDC battery. Communications Port Calibration information during service procedure. Outputs Vent: Cooling vent for internal ventilator components Remote Alarm Connection for optional alarm accessories. Communications Port Connector for optional printer

 


Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Ventilator?

Quantity
Seller Contact Details
  • Seller Rajas Enterprises (india)
  • Address Kuldeep Nagar, Ambala, Haryana
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice