Company Information
Ask for more detail from the seller
Contact Supplier| Sensitivity | 0.2 u V at a 200 ohm input impledane for full scale deflection |
|---|---|
| Noise level | At least 5 DB below full scale at rated sensitivity and maximum bandwidth with input terminated in 100 ohm and 500 ohm for crystal low and hight impedances respectively. |
| Calibration | Square law, meter indicated SWR in dB |
| Range | 70 dB steps, accuracy +- 0.2 dB per 10 dB steps Maximum cumulative error +0.5 dB |
| Scale Selector | Normal, Expand -5dB |
| Meter scale | SWR1-4, SWR3-10, Expand -1.3 dB 0-10, expand dB 0-2 |
| Gain control | Adjust the reference level, variable range 0-10dB approx. |
| Input | "Bolo" bias provided for 4.3 mA low current bolo meters. |
| "Crystal" 200 ohms for low impedance crystal rectifier and 200K ohms high impedance | |
| Crystal | Rectifier as null detector |
| Recorder Output | Socket provided for recording having 1V for Full scale deflection, internal resistance of 1000 ohms or less. |
| A/C Output | BNC connector for amplified output |
| Input connector | BNC(F) |
| Frequency | 1000 Hz+- 10% |
| Amplitude | High gain tuned at one frequency |
| Power | 230 volts A.C +- 10%, 50Hz mains supply. |