Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Water Flow Detector

    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world

    Two-inch conduit openings in new wfd30-2 models ul listed models are nema 4 rated sealed retard mechanism immune to dust and other contaminantsvisual switch activation field replaceable retard....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 12 Years
    • building Nature of Business Manufacturer
    • gst icon GST No. 24AAECS9199P1ZD

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Two-inch conduit openings in new wfd30-2 models
    ul listed models are nema 4 rated
    sealed retard mechanism immune to dust and other contaminantsvisual switch activation
    field replaceable retard mechanism and spdt switches
    rugged, dual spdt switches enclosed in a durable terminal block
    accommodates up to 12 awg wire
    designed for both indooroutdoor use
    100 percent synchronization activates both alarm panel and local bell
    tamper resistant cover screws
    engineering specifications
    vane-type waterfl ow detectors shall be installed on system piping as designated on the drawing andor as specifi ed herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6˝ from any fi ttings which may change water direction, flow rate, or pipe diameter or no closer than 24˝ from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi* for 2˝ – 8˝ pipes. The detector shall respond to waterflow in the specifi ed direction after a preset time delay which is field adjustable. The delay mechanism shall be a sealed techanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual spdt switches (form c contacts). Two conduit entrances for standard fi ttings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be nema 4 listed by underwriters laboratories inc. All detectors shall be listed by underwriters laboratories inc. For indoor or outdoor use.
    static pressure rating
    450 psi*
    maximum surge
    18 feet per second (fps)
    triggering threshold bandwidth (flow rate)
    4-10 gpm
    conduit entrances
    two openings for ½ conduit, one open one knock out type
    contact ratings
    two sets of sp


    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Water Flow Detector?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice