Our Product / Services
Our radiation detector calibration service offers a calibration reminder service, industry-leading support and speedy turnaround times for recalibrations.
Based on the recommendation of AERB, your instrument is calibrated, once in two years from the date it was placed in service.
We are the only organization in India to offer complete service, repairs, recalibration for any kind or brand of Radiation Monitoring Instrument. We are specialized and factory trained to repair Pressurized Ion Chamber survey meters. We have the required plant and machinery to repair these instruments, set the calibration factor and re-calibrate.
Our calibration facility has been recognized by AERB vide their letter no. AERB/RSD/Recog-Cal04/2014/7963 dt.12.8.2014
Facility to calibrate any brand or type of Radiation Survey Meter, Area (Zone) Monitor and Pocket Dosimeters. Either analogue or digital
Pick-up and drop can be arranged, if the need arise
Routine turnaround calibration time is 56 days
Instrument should be in working condition, to avoid delays
Calibration validity TWO years
Included Elements :
the RHLB25PET L Bench, builtin Dose Calibrator shield and Waste bin.
Dimensions:
The Dose Drawing System is used to draw FDG F18 doses from a vial. It consists of a specially designed Dose Drawing Syringe Shield, vial shield and stand.
When drawing FDG F18, the vial shield and syringe shield remain on the stand. The stand allows the vial shield to rotate and has a fixed stop at the 45degree downward angle. The vial shield is constructed of 1" lead encased in steel. The shield's top is threaded to allow quick insertion and removal of vials. The top cover incorporates a pivoting shield for septum access that allows the use of a vent needle, if desired, along with the needle from a 5 cc syringe.
The tungsten syringe shield mounts on a stainless steel rotating platform that slides the syringe into the vial and locks in position. The dose can then be drawn with forceps to minimize hand exposure. The syringe shield is Constructed of .55" tungsten. A highdensity lead glass window allows viewing up to the 5 cc mark on a 5 cc syringe.
The PET Dose Drawing System provides a safe and shielded environment while making it easy to draw a FDG F18 dose.
Klarity Masks are a new higher standard for thermoplastic immobilization. Klarity masks are non stick, stronger, with lower shrinkage than all other standard masks. IMRT AccuPerf pattern offer enhanced perforation designes for higher fixation strength, minimal bolus effect and better patient comfort. Klarity offer largest variety of masks for SType, UFrame, OType, EType, VType, PType, Stereotactic, BoS and various frame types.
Klarity products undergo the most stringent testing methods to ensure the highest quality. All Items are nontoxic thermoplastic compounds manufactured to ISO 13485 specifications and comply with EC and FDA regulations. The Klarity thermoplastics have been analytically tested for Nonallergic Testing and found having ‘No Antigenic Protein’ by Akron Rubber Development Laboratory Inc., Ohio 44305, USA. Accreditated by the American Association of Laboratory Accreditation, District of Columbia, USA.
Key Features :
Klarity supplies a full range of MR Safe baseplates which comply with the carbon fiber baseplates. Klarity MR Safe baseplates are made from composite material of fiberglass and kevlar.
Range :
Technical Specifications
Item | Item No. | |
For CT or Linac | MR Safe | |
Klarity SBRT System | R62400 | R62400‐GF |
Prone Pelvis/Belly System | R620‐ACF2 | R620‐AGF2 |
Cadet AIO Base plate | R612‐NCF | R612‐NGF |
OptekTM Overlay Board | R630‐3SCF | R630‐3SGF |
Klarity Wingboard | R632‐BTCF | R632‐BTGF |
Leg Positioner | R634‐LCF | R634‐LGF |
Indexing Bar | RE‐630E | RE‐630EGF |
RE‐7B | RE‐7BGF |
Interlocking Lead Bricks make it easy to erect, modify and relocate protective walls and caves of any size. Their Vshaped edges eliminate the danger of leakage, common to all straightedged bricks. Interlocking Lead Bricks create sturdy walls for a safe, protective enclosure.
An all-in-one base plate for S-Type masks
The Klarity Cadet AIO Baseplate is configured for multiple treatments and has a narrow profile that is compatible with smaller bore machines.
The Carbon Fiber baseplate can be used to immobilize the head, neck, shoulder, thorax, and pelvis for targeted as well as wholebody irradiation.
The baseplate includes three sinklock channels on either side of the pelvic area to ensure better conformability.
Custom vacuum bags attach to the base plate for further customization.
It also comes with an optional Groin Lock for pelvic masks. The Solo Align™ Baseplate works with all standard Stype head masks. It is also compatible with the R4602436S5T head & shoulder mask, which has a narrow shoulder profile for highly specific positioning.
It is compatible with the Overhead Arm Positioner and Leg Positioner Cushions (supplemental items sold separately). The same baseplate can be made to use for SBRT treatments by fixing Belly and Knee Bridges. A complete allinone solution in real sense, including SBRT.
AllinOne is the only platform which fully meets the needs and even exceeds the expectations of both research and production environments.
The cuttingedge solution for tracer producton and development
Main Features
ConfigurationAllinOne is configurable to match your current needs while remaining easily upgradable with simple plugins as your requirements increase, without any change in software or footprint.
AllinOne can be delivered, with 18 to 36 actuators that can spin the three-way valves to any position including fully closed and with up to 5 syringe drivers, featuring position, speed and pressure control/feedback, one or more heaters withfast cooling capability, strong pinch valves for high pressure reactions, several gas inlet and exhaust ports, freely positionable sub mCi sensitive radiation detectors and with external I/Os to control external instruments directly from the software.
Installed at:
Carbon Fiber flat couch tops securely lock onto a cradle, providing a surface consistent with treatment couch tops. They are lightweight and durable, allowing them to be easily removed or reinserted for use on nondedicated imaging machines. The attachment mechanics ensure that once the top is reinserted on the cradle, it will be level and stable throughout the imaging process. Overlays are made of carbon fiber. All overlays have marking for indexing identical to Linac Couch Top. Provides reproducibility of patient positioning during treatment on Linear Accelerator.
The following Overlay options are available:
‘Medironix’ Manual Styrofoam Cutter is the specialised equipment for the radiation therapy department to cut high consistency block foam mold in CRT. It is easily adjustable to accommodate many sourcetotray and sourcetofilm distances. A verification light allow the operator to check the accuracy of each cut before the blocks are cast. Hot wire with a tensionadjustable organ to ensure that cutting surface. Lowest price in the industry.
CIRS ATOM® phantoms are a full line of anthropomorphic, cross sectional dosimetry phantoms designed to investigate organ dose, whole body effective dose as well as verification of delivery of therapeutic radiation doses.
ATOM is the only line of dosimetry phantoms to range in sizes from newborn to adult. Six models are available: newborn, 1year, 5year and 10year old pediatric phantoms as well as adult male and female phantoms.
Each phantom is sectional in design with traditional 25 mm thick sections. The sectional surfaces are extremely flat and smooth and do not require any special coatings or treatment. This results in minimal interfaces between the slabs when viewed in a scout or projection Xray. The ATOM line also differs from other dosimetry phantoms by providing optimized TLD locations specific to 21 inner organs.
Tissueequivalent epoxy resins are used in all aspects of the phantom. CIRS technology offers superior tissue simulation Dosimetry Verification Phantoms by covering a wider range of energy levels from diagnostic to therapeutic. In addition, all bones are homogeneous and are formulated to represent age appropriate, average bone composition. CIRS bone formulations offer distinct advantages over natural skeletons and other types of simulated bone.
A complete, mobile, selfcontained Medical Spectrometer System The Atomlab 960 Thyroid Uptake System is an advanced multipurposespectrum analysis instrument designed for diverse nuclear medicine applications. Uptake studies, wipe tests, and other userdefined tasks are accomplished with speed and precision using this fully integrated computercontrolled instrument and its comprehensive selection of application software. The system’s multichannel analyzer has 1024 channels, with individual MCAs for the probe and optional well counter. Engineered for mobility, durability and operational efficiency, the Atomlab 960 handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Intuitive menus follow conventionally established nuclear medicine procedures, providing step-bystep guidance throughout all defined procedures.
The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. Userdefined uptake protocols can be initiated.
Medical Spectrometer Software
Radionuclides
Economical and efficient system for your basic fume hood needs. Sturdy ergonomic design for uniform flow control to ensure clean and odor free working environment.
The CIRS Dynamic Thorax Phantom is a precision instrument for investigating and minimizing the impact of tumor motion inside the lung. It provides known, accurate and repeatable threedimensional target motion inside a tissue equivalent phantom. It is designed for comprehensive analysis of image acquisition, planning and dose delivery in imageguided radiation therapy. The phantom body represents an average human thorax in shape, proportion and composition. A lung equivalent rod containing a spherical target and or various detectors is inserted into the lung equivalent lobe ofthe phantom. The body is connected to a motion actuator box that induces threedimensional target motion through linear translation and rotation of the lung equivalent rod. Motion of the rod itself is radiographically invisible due to itsmatching density with the surrounding material. The target and its motion, given its density difference, can be resolved.
Advised by AERB “Last Man Out Switch” (LMOS) is designed for radiation safety. Soon after patient setup, the technician needs to press the LMOS after ensuring that nobody is present in the treatment room. This activates an audiovisual alarm for 30 seconds and during this period the operator needs to close the door and switch “ON” the beam. Works on latest micro controller based technology. Simple to install and easy to use.
miniAllinOne is a unique compact synthesizer dedicated to the preparation of diagnostic and therapeutic radiotracers. You can use this synthesizer for the production of radiotracers labelled with 68Ga, 177Lu, 99mTc, 89Zr, 64Cu, 90Y, 188Re, 203Pb among others, all on the same instrument to meet the evolving needs of the nuclear medicine department.
The synthesizer for diagnostic and therapeutic radiotracers
Routine ProductionminiAllinOne is the best choice for easy and reliable routine delivery of radiopharmaceuticals thanks mainly to:
This platform allows radiotracers labelled with 18F, 68Ga, 177Lu, 99mTc, 89Zr, 64Cu, 90Y, 188Re, 203Pb to all be prepared with the same instrument. A range of dedicated tabletop and wheelmounted compact hot cells ensures a perfect protection and ergonomic working condition.
Ready to Use ConsumablesCassettes and reagents for each tracer are available for miniAIO. The comprehensive reagent kits avoid the need of sourcing consumables from several suppliers. Cassettes are GMP manufactured and are provided in individually sealed pouches, fully assembled and ready to use. The RFID chip scanner system avoid manual transcription mistakes and warrants operators to work with the right reagents kits. Subsequent cassette rinsing eliminates most of the residual activity allowing a quick replacement for any upcoming production.
Installed at:
The high dose per fraction associated with SBRT necessitates a high degree of accuracy in target localization and dose delivery. Small errors can result in significant under treatment of portions of the tumor volume and over dosages of nearby normal tissues. The E2E® SBRT Phantom provides a means to check the entire treatment chain during commissioning and routine QA.
The Model 036ACVXXxx* is an anthropomorphic thorax body containing articulated spine, ribs and lungs.
The Shielded Decay Drum provides safe handling and storage of radioactive waste material. The drum features a toploading, handled lid with a 6" x 8" drop port. Each drum includes a plastic drum placed inside.
Available models
This Shielded Waste Container is used in facilities that generate lowenergy beta and gamma radiation waste.
Available models
Horus and Laserstar The Perfect Combination for Patient Marking and Positioning in Radiotherapy
The complete redesigned next generation of our laser systems convince with stateoftheart technology in a modern look and feel. HORUS and LASERSTAR are durable, reliable and trusted high precision tools for the daily use in your advanced workflow for virtual simulation and patient positioning.
A2J HORUS Moving Laser System The moveable laser lines are supporting your radiotherapy treatment planning for a precise and highly accurate marking on the patient skin.
Horus 1
Horus 3
Horus 5
Klarity Frameless SRS System provides highest degree of stability for head, neck and shoulder. The system includes Klarity Demi Optek Board, Shell molds (set of three), Silverman head rests (set of six) and a variety of customised AccuCushions for individual fixation.
The Klarity Shell Mold is reusable frame for molding Shell AccuCushions. Once the AccuCushion cools within the frame, the Shell Mold is removed before a mask is used. Includes three sizes, Klarity AccuCushionsTM are used underneath a thermoplastic mask for increased fixation and better patient comfort. AccuCushionsTM are available for Head & Neck and Head & Shoulder Support. Our Shell Cushions offer advanced full circumferential support, and we also have AccuCushionsTM to fit specific base plates and treatments systems. Simple to use with no pungent odor. Can be reheated and reshaped. Comforting and calming patient effect. Improved positioning accuracy.
ATOM MAX Dental & Diagnostic Head PhantomThe CIRS ATOM Max Dental and Diagnostic Head Phantom is a standard of reference for diagnostic radiology of the head. The phantom is designed to assist technical and clinical staff in the selection, monitoring, training and verification of scanning parameters common to most radiological procedures requiring fine anatomical details.
CT Dose PhantomFor all computed tomography systems, the Food and Drug Administration recommends measuring the CT Dose Index (CTDI). Each section of the CIRS CT Dose Phantoms can provide separate dose information. The user can also measure maximum, minimum and midrange values of the nominal tomographic section thickness when performing dose profile measurements.
Each phantom consists of a set of nesting 15 cm thick solid PMMA disks
AAPM CT Performance PhantomThe CIRS Model 610 AAPM CT Performance Phantom offers the user a single test object that measures ten distinct CT performance parameters. The phantom design is based on the guidelines presented in Report #1 of the American Association of Physicists in Medicine Task Force on CT Scanner Phantoms. The goals of report #1 were to “(1) define ‘performance’ of a CT scanner and (2) describe methods of performance testing through utilization of particular phantoms.”
A Measurement Capabilities:
The Atomlab 500 can be used for a wide variety of nuclear medicine, PET and radioimmunotherapy applications, with proven performance for fast, accurate measurements. The system consists of a low pressure ionization chamber, electrometer with extraordinary linearity, and an autoranging color touchscreen display. Additionally, there are advanced, but easytouse programs for nuclear pharmacy.
An extensive selection of quality assurance applications streamlines and simplifies hot lab administration requirements
OperationThe system is easy to use. There are 12 isotope selection touch keys preprogrammed for the most commonly used radionuclides. Any of those keys can be reprogrammed by the user for a desired isotope. There are 97 isotopespecific dial values listed in the library. Dial values can easily be changed if required.Activity is displayed on the color display in either Curie or Becquerel units. Background correction is performed at the touch of a button. Range selection is automatic, from .01 microcurie to 100 Curies of Tc99m or 25 Curies of F18.
Quality AssuranceThe Atomlab 500 has been designed to make life easier. The extensive selection of quality assurance applications streamlines and simplifies hot lab administration requirements. The system stores and decay corrects multiple reference sources and compares the measured activity to the calculated activity for the daily constancy test.
Linearity tests can be performed in the traditional manual method or by a fully automated program that allows for readings from a source to be taken, and automatically recorded at specified intervals. The system will graph the results.
The attenuation tube test for linearity can be performed using software that will guide the user through the procedure, store the values and make all calculations.
Specifications
MurphilPET is an innovative shielded Isolator designed for manipulation of PET radiopharmaceuticals. The unique design makes it ergonomic, functional and ideal to simplify all routine operations performed in a Nuclear Medicine facility, in compliance with Radioprotection and GMP rules. MurphilPET is not just for gamma emitting isotopes; thanks to a “β shielding” upgrade kit it is also a valid solutions for the manipulation of the Beta emitting therapeutic radiopharmaceuticals.
The Isolator adopts a constructive standard ELS® (Encapsulated Lead System) it consists in encapsulating the lead shieldings inside of closed frames avoiding lead contamination of environments. Also available with a plug & play dispensing for syringes Fast Dose Class “B” prechamber for Generators and Synthesis modules (68Ga).