My ExportersIndia

For Buyer

For Seller

For Help

Gps Tracking Device

We offer a complete product range of i Pack GPS GSM/GPRS Device and I Pack GPS ACCESS DEVICE

I Pack GPS GSM/GPRS Device

  • One (1) built-in 12V Sealed Lead-Acid (SLA) battery with 2200 mA-hr rating 12 V (nominal) solar PV panel or external power supply (15 to 24 V)
  • External battery (12 - 14 V) Windows PC with desktop software for applicable data logger model: SymphoniePRO Desktop Application for SymphoniePRO Data Logger Symphonie Data Retriever (SDR) for SymphoniePLUS3 and older Symphonie series data loggers
  • SymphoniePRO Desktop Application requires Windows XP or later Symphonie Data Retriever (SDR) requires Windows 95 or later iPack Programming Kit (Item 3368) Universal iPack Charger (Item 3615; included in 3368)
Symphonie iPackGPS GSM/GPRSSymphonie iPackGPS GSM/GPRS

Automate the transfer of measurement data from the project site to your desktop through a GSM/GPRS network

The Symphonie iPackGPS GSM/GPRS is an internet-enabled communications and autonomous power module for Symphonie series data loggers. Utilizing a specialized GSM cellular modem that connects your data logger to the internet through a 2G GSM cellular network, iPackGPS delivers measurement data to your desktop anywhere in the world.

SymphoniePRO

New!When used with the SymphoniePRO Data Logger, iPackGPS enables remote bi-directional communication with the SymphoniePRO Desktop Application using our MetLink protocol in addition to the traditional SMTP email data delivery path. MetLink connections can be initiated either by the logger or the SymphoniePRO Desktop Application, allowing you to connect remotely as needed.

Flexible scheduling options and support for multiple data delivery methods provide redundant paths for the transfer of critical resource data. Once established, remote MetLink connection sessions provide full access to the data logger and iPack, including:

  • Automated or manual download of data files (alternative to SMTP email)
  • Live data viewing for site health checks
  • Configuration settings changes in the data logger or iPack
  • Firmware upgrades to the data logger or iPack

Data Logger Connection

iPackGPS attaches to a port located on the back of your Symphonie series data logger. The iPackGPS and the data logger are then secured to the Symphonie shelter box using four screws.

Power Supply

The iPackGPS GSM/GPRS contains one rechargeable 12 V sealed lead-acid battery and a recharging circuit. The battery recharging circuit is designed for use with an external 15W PV panel that connects to terminals on the side of the iPackGPS. Terminals for an external power system are also available. This configuration keeps the internal batteries continuously chargedensuring reliable data logging and transfer operations.

Cellular Antenna

Each iPackGPS GSM/GPRS ships with an omnidirectional antenna appropriate for sites where a cellular tower is nearby.

Accounts and Programming

The iPackGPS GSM/GPRS requires GPRS data service and, if utilizing email for data delivery, an SMTP host to function properly. GSM and email server accounts need to be obtained from the provider(s) of your choice, and the required settings for the accounts should be programmed into the Symphonie iPackGPS prior to use.



Benefits
  • Automatic transfer of logged data via email, or additionally via direct MetLink connection when used with SymphoniePRO
  • Worldwide operation from any location with 2G GSM service
  • Integrated autonomous power supply saves installation time and powers entire system
  • Customizable data transmission fits your schedule or application with call intervals ranging from 10 minutes to 14 days
  • WindLinx-ready wireless service and web-based management portal
  • Access to network information including signal strength, network operator, modem band, DNS, and IP address
  • Complete iPackGPS history log to monitor events from communication sessions
  • Automated GPS coordinate reporting
  • Ability to remotely update the iPackGPS firmware and configuration

In The Box
  • One (1) Symphonie iPackGPS (GSM/GPRS)
  • One (1) cellular antenna
  • One (1) GPS antenna
  • PV panel sold separately -Symphonie PV Panel 15W

Note:The iPack voltmeter SCM is now included in SymphoniePLUS3 data logger kits. SymphoniePRO includes built-in monitoring of the 12V power supply and does not require a separate interface module.

Specifications
  Symphonie iPackGPS | GSM/GPRS (#4723)
Description
Accessory type Internet-enabled remote communication and autonomous power module for Symphonie® series data loggers
Applications
  • SymphoniePLUS and Symphonie data logger internet features where GSM service is available
  • Quad band operation for GSM 850/900/1800/1900 MHz
  • Europe, Asia, North America
Instrument compatibility All Symphonie series data loggers
Functions SymhoniePRO Only Functions
  • Enables remote MetLink connections for real-time two-way communication, including automated data delivery, firmware updates, and/or configuration updates to data logger and iPackGPS
  • GPS time synchronization
  • Cellular band and operator management via SymphoniePRO Desktop Application

    All Symphonie Series functions:
  • Automatic transfer of logged data via email
  • Automatically updates latitude, longitude, and altitude settings in the data logger
  • GPS position viewer
  • iPackGPS status and event reporting*
  • GSM (cellular) signal confirmation indicator
  • Accepts remote firmware updates*
  • Automatic real-time clock setting from internet time server
  • Remote parameter updates of Symphonie series data loggers and iPackGPS*
  • Ability to disconnect a call in progress
  • Event log viewer*
  • Includes rechargeable battery and PV charge controller for the data logger

    *Function enhanced with SymphoniePRO
Data Collection
Software For SymphoniePRO Data Logger:
  • SymphoniePRO Desktop Application

    For Symphonie data loggers SymphoniePLUS3 and older:
  • Symphonie Data Retriever (SDR)
Data delivery For SymphoniePRO Data Logger:
  • Data delivery via SMTP email and/or MetLink connections
  • Configuration changes and firmware updates administered via MetLink connections
  • Test functions for all data delivery methods, with access to these features from both the logger LCD and SymphoniePRO Desktop Application

    For Symphonie data loggers SymphoniePLUS3 and older:
  • Data delivery via SMTP email
  • Confiuration changes uploaded via email
Configuration
User interface
  • Status reporting on data logger front panel
  • Configuration via desktop software on Windows PC
Configurable parameters For SymphoniePRO Data Logger
  • Internet Service Provider settings
    Other settings (schedule, SMTP, etc.) stored in data logger allowing minimal disruption to settings in the event of iPack swap.

    For Symphonie data loggers SymphoniePLUS3 and older
  • Call interval range: 10 minutes - 14 days
  • Internet Service Provider settings
  • Optional 'No Partial Files' setting (SymphoniePLUS3)
  • Configurable SMTP and POP3 ports (POP3 used only on SymphoniePLUS3 and older Symphonie models)
  • Optional 'Disable POP3' setting (SymphoniePLUS3)
  • Up to three (3) email addresses
Power requirements
Batteries One (1) built-in 12V Sealed Lead-Acid (SLA) battery with 2200 mA-hr rating
External solar input 12 V (nominal) solar PV panel or external power supply (15 to 24 V)
Other External battery (12 - 14 V)
Installation
Mounting
  • iPack stacks with Symphonie data logger using long logger mounting screws (included)
  • Logger and iPackGPS attach to logger mounting bracket; Keyed slots allow for easy installation/removal in shelter box
  • Standard multi-band cellular antenna is magnetically mounted to top of shelter box
  • GPS antenna is magnetically mounted to top of shelter box
  • An optional 15W solar PV panel (sold separately) mounts to your tubular tower with supplied hose clamps
Tools required 8 mm (5/16") wrench or nut driver for mounting screws
Accessories Cellular antenna and GPS antenna included
Physical
Connections
  • Data connection to iPack connector on rear of data logger
  • Two (2) screw terminals for solar PV panel or external power supply input
  • Two (2) screw terminals for external battery
  • One (1) screw terminal for earth ground pre-wired for connection to data logger earth ground stud
  • GSM antenna connector SMA female
  • GPS antenna connector QMA female
  • Programming port connection via data logger programming adapter, or USB in case of SymphoniePRO
Dimensions 165 x 222 x 51mm ( 6.5 x 8.75 x 2.0")
Materials
Enclosure Polycarbonate plastic
System requirements
Computer Windows PC with desktop software for applicable data logger model:
  • SymphoniePRO Desktop Application for SymphoniePRO Data Logger
  • Symphonie Data Retriever (SDR) for SymphoniePLUS3 and older Symphonie series data loggers
Operating system
  • SymphoniePRO Desktop Application requires Windows XP or later
  • Symphonie Data Retriever (SDR) requires Windows 95 or later
Related hardware
  • iPack Programming Kit (Item 3368)
  • Universal iPack Charger (Item 3615; included in 3368)











View Complete Details

I Pack GPS ACCESS DEVICE

  • One (1) built-in 12V Sealed Lead-Acid (SLA) battery with 2200 mA-hr rating 12-14V DC (Continuous: 100mA, Max 200mA)
  • 15-28V DC (Continuous 100mA, Charging Max 750mA) Power for attached sensors is not included in these values
  • SCADA-enabled communications module for the SymphoniePLUS3 data logger Real-time and statistical data is accessible to wind farm SCADA system via MODBUS TCP Wind resource assessment data is available by email if internet is accessible via wind farm network
Symphonie iPack ACCESS

Integrate real-time, one-second meteorological data into your SCADA (Supervisory Control and Data Acquisition) system.

Details

iPackACCESS is a communications module for the SymphoniePLUS3 Data Logger that enables wind farm operators to integrate real-time, one-second meteorological data into their SCADA (Supervisory Control and Data Acquisition) systems.

In addition to real-time data, iPackACCESS calculates statistical data at user-selected intervals. Data are delivered to pre-defined Modbus registers. With no coding required, iPackACCESS offers ease-of-use and data security by limiting access to defined IP addresses.

Data Logger Connection

iPackACCESS attaches to a port located on the back of the SymphoniePLUS3 Data Logger. The iPackACCESS and SymphoniePLUS3 are then secured to a Symphonie shelter box using four screws.



Benifits
  • Integrate real-time, one-second meteorological data into your wind farms SCADA system
  • Calculate statistical data (average, standard deviation, min, and max) at user-selected intervals (1, 2, 5, 10, 15, 30, and 60 minutes) so it can be directly forwarded to forecasting providers
  • Access the data on pre-defined registers using Modbus TCP protocol
  • Ensure the security of your data by limiting access via user-defined IP addresses
  • Quickly install the unit in the field, no coding required
In The Box
  • One (1) Symphonie iPackACCESS
  • One (1) GPS antenna

Note:The iPack voltmeter SCM is now included in SymphoniePLUS3 data logger kits. SymphoniePRO includes built-in monitoring of the 12V power supply and does not require a separate interface module.

Description
Accessory type SCADA-enabled communications module for the SymphoniePLUS3 data logger
Applications
  • Real-time and statistical data is accessible to wind farm SCADA system via MODBUS TCP
  • Wind resource assessment data is available by email if internet is accessible via wind farm network
Instrument compatibility SymphoniePLUS3 data logger
Functions
  • MODBUS TCP server available over ethernet connection
  • Supports up to 4 simultaneous MODBUS TCP connections
  • Install firmware updates to iPackACCESS remotely
  • Automatic real-time clock setting from internet time server
  • Automatic download of logged data via email if internet is accessible via wind farm network
Data Collection
Software Configured with Symphonie Data Retriever (SDR)
Data delivery
  • Real-time, 1-second values of all 15 channels in both raw and scaled format is available from MODBUS TCP server
  • Mean, standard deviation, minimum, and maximum values at user-selected time interval in both raw and scaled format is available from MODBUS TCP server
  • SymphoniePLUS3 10-minute data is available by email if internet is accessible via wind farm network
Configuration
User interface
  • Status reporting on data logger front panel
  • Configuration via SDR on Windows PC
Configurable parameters
  • MODBUS secure client list to prevent unauthorized access by limiting the acceptable IP addresses for incoming connections (up to 10 allowable addresses)
  • Network configuration parameters
  • DHCP capable
  • User-selected time interval for statistical data calculation (1, 2, 5, 10, 15, 30, 60 minutes)
  • Similar wind resource assessment configuration parameters to iPackGPS
Connections
Communication ports
  • Weather-proof Ethernet connector (RJ45) for connection to SCADA system
  • SymphoniePLUS3 to iPackACCESS via DB25 interface
  • GPS antenna connector QMA female
Power requirements
Batteries One (1) built-in 12V Sealed Lead-Acid (SLA) battery with 2200 mA-hr rating
External power input 12-14V DC (Continuous: 100mA, Max 200mA)
External solar input 15-28V DC (Continuous 100mA, Charging Max 750mA)
Other Power for attached sensors is not included in these values
Installation
Mounting iPackACCESS stacks with SymphoniePLUS3 data logger on long logger mounting screws
Accessories Weather-proof Ethernet cable boot, and GPS antenna included
Physical
Connections
  • Two (2) screw terminals for solar PV panel or external power supply input
  • Two (2) screw terminals for external battery
  • One (1) screw terminal for earth ground, pre-wired for connection to data logger earth ground stud
Dimensions 165 x 222 x 102 mm (6.5 x 8.75 x 4.0 inches)
Materials
Enclosure Weather-proof polycarbonate plastic
System requirements
Computer Windows PC with Symphonie Data Retriever (SDR) required for programming of iPackACCESS settings.
Operating system Symphonie Data Retriever (SDR) requires Windows 95 or higher
Related hardware
  • SymphoniePLUS3 Data Logger (Item 5504)
  • iPack Programming Kit (Item 3368)
  • Universal iPack Charger (Item 3615)
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us