We are leaders in the market for providing best range of Mild Steel Thermic Fluid Heaters, Thermic Fluid Heaters, Solid Fuel Fired Thermic Fluid Heaters, Thermic Fluid Heaters-01 and Fuel Fired Thermic Fluid Heaters

Mild Steel Thermic Fluid Heaters

  • Material Stainless Steel, Mild Steel
  • Temperature 300 deg C
  • Pressure I to 3 bar
  • Min Capacity 1, 00, 000 Kcals/hr
  • Max Capacity 40, 00, 000 Kcals/hr
  • Mounting Skid-mounted
View Complete Details

Thermic Fluid Heaters

ALFA - Oil & Gas Fired Thermic Fluid Heaters

At high temperature, water and steam requires a corresponding high operating pressure. Establishing this with water and steam can be very controversial and expensive. In thermic fluid heaters a thermal oil is used instead as the heat carrier, operating at low pressure to deliver 300oC temperature. In comparison water and steam, would require a pressure of 85 bar to obtain this temperature. There are several advantages of using thermic fluid heaters compared to steam boilers. the ost obvious are,

  • High temperature up to 300oc at low pressure of 1 to 3 bar
  • No equipment for pre-treatment of boiler feed water
  • No heat loss due to hot condensare and flash steam discharge
  • No risk of corrosion
  • Low maintenance costs
  • Easy to operate (does not require a steam boiler certified operator)

The ALFA thermic fluid heaters are thermodynamically optimized & are characterized by high efficiency & excellent heat transfer to the thermic fluid. The combustion chambers are generously dimensioned & are sufficiently long. The flame can thus burn fully & the emission values remain very low for all fuel types. ALFA has the following distinct advantages

  • Large heating surface area hence higher efficiency
  • Hinged front door for easy cleaning & inspection
  • Rugged construction
  • Maximum running reliability

Capacities available are from 1, 00, 000 Kcals/hr to 40, 00, 000 Kcals/hr. Fuel firing options are light oil, heavy oil, gas or dual fuel. Units are also available in vertical designs.

View Complete Details

Solid Fuel Fired Thermic Fluid Heaters

delta - solid fuel fired thermic fluid heaters

solid fuel fired thermic fluid heaters are available in capacities from 1, 00, 000 kcals/hr up to 40, 00, 000 kcals/hr. The vertical design with integral furnace assures rated output on any solid fuel like coal, wood & bagasse. The well planned design of the delta ensures thermal expansion with low stress. the basic advantages of the delta arc,

  • low operating cost
  • reliable operation
  • safety against low thermic fluid flow
  • precise thermic fluid temperature control

expansion cum dearator tank the expansion chamber cum deaerator tank is designed to ensure long fluid life. The combined tank has a unique design & offers significant protection against oxidation of thermic fluid. Tangenitial thermic fluid entry in the deaerator tank ensures good deaeration.

Delta Vertical Units

Model Heat Output(Kcals/hr)
DELTA 100 100000
DELTA 200 200000
DELTA 300 300000
DELTA 400 400000
DELTA 600 600000

Delta Horizontal Units

ModelHeat Output (Kcal/hr)
DELTA 400400000
DELTA 600600000
DELTA 800800000
DELTA 10001000000
DELTA 15001500000
DELTA 20002000000
DELTA 25002500000
DELTA 30003000000
DELTA 35003500000
DELTA 40004000000
View Complete Details

Thermic Fluid Heaters-01

ALFA - Oil & Gas Fired Thermic Fluid Heaters

At high temperature, water and steam requires a corresponding high operating pressure. Establishing this with water and steam can be very controversial and expensive. In thermic fluid heaters a thermal oil is used instead as the heat carrier, operating at low pressure to deliver 300oC temperature. In comparison water and steam, would require a pressure of 85 bar to obtain this temperature. There are several advantages of using thermic fluid heaters compared to steam boilers. the ost obvious are,

  • High temperature up to 300oc at low pressure of 1 to 3 bar
  • No equipment for pre-treatment of boiler feed water
  • No heat loss due to hot condensare and flash steam discharge
  • No risk of corrosion
  • Low maintenance costs
  • Easy to operate (does not require a steam boiler certified operator)

The ALFA thermic fluid heaters are thermodynamically optimized & are characterized by high efficiency & excellent heat transfer to the thermic fluid. The combustion chambers are generously dimensioned & are sufficiently long. The flame can thus burn fully & the emission values remain very low for all fuel types. ALFA has the following distinct advantages

  • Large heating surface area hence higher efficiency
  • Hinged front door for easy cleaning & inspection
  • Rugged construction
  • Maximum running reliability

Capacities available are from 1, 00, 000 Kcals/hr to 40, 00, 000 Kcals/hr. Fuel firing options are light oil, heavy oil, gas or dual fuel. Units are also available in vertical designs.