Our Products
Our Complete range of products are Three Phase Control Panel, Snr/IP 2007 3 PH. Control Panel, Snr/IP/dms (Rly) 3 PH. Control Panel, SNR/3PH/ALT-2(RLY) Three Phase Pump Control Panel and Three Phase Control Panel (model No. Ip 2007).
(SNR/3PH-S/D-ECO)
Features:
Micro Controller Based Technology
Motor starts automatically after time delay of 1 / 3/5 min. (enable/disable facility)
Operates on low voltage (250V)
Useful for 3 Ph. Submersible, monoblock pumps.
Useful for Fire Fighting motor pumps starter, water supply scheme for gram panchayat
Separate Indicator for time, OK, 0/L, SPP, Dryrun.
Standard make contractor and thermal relay for switching.
Auto/Manual facility on front panel.
Heavy MS steel fabricated box with high quality powder coating like outdoor type.
Digital Amp. & Voltmeter for display current and voltage.
Panel material can be changed as per requirement of customer.
Water level controller & other facility can be added as per requirement.
In Reverse phase condition SPP LED blinks and display shows rsp.
Technical Specifications:
(As per SNR/IP 2007)
and as per Auto switch RDM
3 PH. CONTROL PANEL
(SNR/IP 2007)
Features:
Microcontroller based technologyMotor starts automatically after time delay 1/3/5 minProtection from voltage & current unbalance, single phasing, overload & dry run. (auto push button setting)RYB indication for each phaseOperates on low voltage (from 250 V)
Useful for 3 Ph. 1 to 6 H.P. Openwell, Submersible, Monoblock pumpsets.
Separate indicators for Timer, OK, SPP, Dry run & 0/L.Auto / Manual Facility.3 pole MCB for mains ON/OFF & Short circuit protection
Technical Specification:
Operating voltage: 220 to 460 VAC, 50 Hz.Dry Run trip timing - 7 sec.Overload Electromagnetic Relay.Dry Run setting -70% of full load current.SPP Trip time delay - 4 sec.Voltage Unbalance Set - 35 volts.Voltage Sensing SPP.
3 PH. CONTROL PANEL (UP TO 5 H.P.)
(SNR/IP/DMS (RLY)
Features:
Micro Controller Based Technology
Motor Autostart Facility with settable on delay time.
Protection from voltage unbalance, single phasing, overload, Dryrun & also current sensing SPP, (Push button for Setting)
LED Display for voltage & ammeter & also indicator
40 A power relay for ON/OFF switching.
Compact size.
0/L percentage can be settable from 110% to 170%.
N/L % can be set from 90% to 50%
After Dry run trip restart relay facility available (with variable time set).
SPP/0/L protection enable/disable facility, as per DMA
Useful for 3 Ph. 1 to 5 H.P. Openwell, Submersible, Monoblock pumps.
Auto/Manual Facility.
Water level controller facility also available.
In reverse phase condition SPP LED Blinks and display shows rsp.
Technical Specification:
As per Model - IP2007
1 PH. & 3 PH. ALTERNATE PUMP OPERATING PANEL
SNR/3PH/ALT-2(RLY)
Features :
Microcontroller based technology.
Useful for 1 Ph. & 3 Ph. Pumps.
Same protection & features as per RDM Auto Switch.
Two separate contactors for operate each motor.
Auto/Manual / By pass facility.
Input timer for alternate.
ON/OFF Switch for pump 1 & Pump 2.
One pump can operate at one time and next time other pump is operate in Auto mode only.
All Indication of facility are available in panel.
Technical Specifications as per Autoswitch RDM