Post Buy Requirement
SI
Hyderabad, Telangana, India
Add Review

Other Products / Services

Air Shower Interlocking System

  • Features Advanced Micro controller based. , Digital Display with soft tactile keypad.
  • LED Indications for push buttons: GO/WAIT.
  • Input Voltage 24Watt at 80-280VAC, 50Hz.
  • Operating Voltage 12V / 24V DC.
  • Dimensions for DPM 110mm L x 90mm W x 20mm D.
The Air shower is a supporting device for the clean workshops and the assembly clean room, is used to blow the dusts attached to the surfaces of the people and objects entering the clean workshop, and also functions as an air brake to prevent non-purified air from entering the clean area.
View Complete Details

Pass Box Interlocking System

  • Features Timer value can set by using 3keys keypad. and Password protection for Timer value setting.
  • Contact Material: Silver Alloy.
  • Contact Rating: 230V AC / 2 A.
  • Mechanical 107
  • Electrical 105.
  • Input Voltage 24Watt at 80-280VAC, 50Hz.
  • Operating Voltage 12V / 24V DC.
In the process of material transfer from unclassified area to classified area pass boxes are used. The doors are interlocked such a way that doors cannot be open at the same time, due to which pressure losses and bacterial contamination doesn't takes place throughout the material transferring process. The prevention of simultaneous access of doors is been achieved by our Pass Box controller by ensuring that when one door for a Pass box is open then other doors closed.
View Complete Details

Pass Box Interlocking System

  • Contact Material Silver Alloy
  • Contact Rating 230V AC / 2 A.
  • Mechanical 107
  • Electrical 105
  • Input Voltage 24Watt at 80-280VAC, 50Hz.
  • Operating Voltage 12V / 24V DC.

in the process of material transfer from unclassified area to classified area pass boxes are used. The doors are interlocked such a way that doors cannot be open at the same time, due to which pressure losses and bacterial contamination doesn't takes place throughout the material transferring process. The prevention of simultaneous access of doors is been achieved by our pass box controller by ensuring that when one door for a pass box is open then other doors closed.



features:

  • advanced micro controller based 2door or 3door static/dynamic passbox interlocking system.

  • status indications with high intensity red color bar led's.

  • door status indications like go, wait, close door, door open messages or locked, released for every pushbutton.

  • buzzer output for door is kept open more than pre-programmed time from 1 to 30 min.

  • timer value can set by using 3keys keypad.

  • password protection for timer value setting.

  • timer value can set maximum of 999 sec/mins.

  • when door 1 is opened the display on the door 2 and door 3 will indicate wait and at the door 1 the display will indicate door open.

  • when any of the door is kept open beyond a particular time say 2 min, buzzer will be blown and the display at the doors will indicate close door.

  • uv lamp controlling.

  • blower fan controlling.

  • cf lamp controlling.

  • all doors are provided with electromagnetic locks/electric strikers.

  • 3 digit 0.39 7-segment red led to display the timer value.

  • soft-touch membrane keypad provided to program timer values.

  • 3mm diffused red led for blower failure indications.

  • soft-touch membrane keypad provided to program timer value.

  • soft-touch membrane keypad provided to control laf/buf controls.

  • 3mm diffused bi-color led indication to display on/off status of uv, cf, blower.

  • door delay time: pre programmed as per the requirement.


specifications:

  • mode of operation: nc or no.

  • pushbutton inputs based on doors max up to 3 doors.

  • door feedback inputs based on doors max up to 3 doors.

  • door control outputs based on doors max up to 3 doors.

  • led indications for push buttons: go/wait.

View Complete Details

Electronic Status Board

  • DP -105.4 to 105.4 mmWC, -1034 to 1034 Pascal's and 8 types of units with equivalent values.
  • %RH 0.0 to 100%RH.
  • Temperature 40°C to 100°C.
  • Clock HH:MM (Hours and Minutes format only)

the styrax electronic status board has been specially developed keeping process measurement requirements of clean rooms in pharmaceutical industries. The process scanner can measure temperature, rh inbuilt integral sensor, differential pressure inbuilt sensor or three analog inputs or two analog inputs and inbuilt differential pressure sensor. It has on demand dew point display. The scanner has status leds for process violation indication. Rh, temperature and differential pressure will display individually and data transfers to any master device on modbus rtu rs-485 communication. It has individual communication diagnosis led's for scada communication and status application communication. The scanner has inbuilt buzzer for audible process violation. It has keypad to program and calibrate the instrument by user. It has stainless steel modular face plate, which is designed as a mounting accessory for monitor suited for brick and modular wall for clean room applications where you need flush mounting mechanism.



features :

  • advanced microcontroller based process measurement.

  • programmable channel ranges and unit selections.

  • 4 digit, 0.8 bright 7- segment led display for displaying temperature, rh and dp.

  • 10- digit 0.56" bright 16-segment led display for displaying activity.

  • 20- digit 0.56" bright 16-segment led display for displaying name of product.

  • 10- digit 0.56" bright 16-segment led display for displaying batch number.

  • user selectable set limits for process value violation.

  • process parameter status indication with 3 bi-color 3mm leds.

  • inbuilt buzzer to audible process value violation.

  • password protection for calibration and programming mode.

  • software calibration for 3 channels using front panel keypad.

  • modbus rtu multi drop rs-485 serial communication for plc, scada, etc.

  • rs485 interface to batch status application.

  • programmable baud rate between 9.6k/19.2k/38.4k.

  • diagnosis indication of communication with scada and batch status application.

  • user programmable offset correction.

  • brick and modular wall mounting.

  • stainless steel enclosure.

Accuracy
%RH ±2% RH for 10 to 90% and±4% RH for remaining.
Temperature : ±0.3°C for 0°C to 50°C and 2°C for remaining.
DP ±1.5% for all units.
Clock ±0.5 Second (In case of communication with Master Clock)
±2 minutes per year (In case of communication failed with Master Clock)
Resolution
%RH 1/0.1% RH
Temperature 1/0.1°C.
DP 0.1mmWC
Power supply
24VDC/24VAC.
         

Model No. Input Type No. of Channels Display Dimensions
CRI105I Inbuilt Sensor 3 0.8" for Parameter and 0.56" for status display 200 x 315 x 35
CRI105I 4-20mA 3 -do- 200 x 315 x 35
CRI105V 0-10VDC 3 -do- 200 x 315 x 35
View Complete Details

Surveillance Camera

Closed - circuit television (CCTV) cameras can produce images or recordings for surveillance purposes, and can be either video cameras, or digital stills cameras.
View Complete Details

Digital Temperature Process Scanner

  • Feature Advanced Microcontroller based process measurement. , Programmable resolution.
  • %RH 0.0 to 100%RH.
  • Temperature 40°C to 100°C.
  • Clock HH:MM (Hours and Minutes format only)
The STYRAX Clean Room Process Scanner has been specially developed keeping process measurement requirements of CLEAN ROOMS in Pharmaceutical industries. The Process Scanner can measure Temperature, RH Inbuilt integral Sensor, Differential Pressure Inbuilt sensor or three analog inputs or two analog inputs and inbuilt differential pressure sensor. It has on demand dew point display. The Clean Room Process Scanner displays Real Time Clock synchronized with GPSServer based master clock interfaced through RS485
View Complete Details

Air Shower

The Air shower is a supporting device for the clean workshops and the assembly clean room, is used to blow the dusts attached to the surfaces of the people and objects entering the clean workshop, and also functions as an air brake to prevent non-purified air from entering the clean area.
The Air Shower system controls the sequential locking and release of the doors, and controls the Blower. The two doors are interlocked such that two doors cannot be open at the same time, to prevent pressure losses and cross contamination.
View Complete Details

BUF Controller

  • Blower Relay O/P 230V AC / 2 A (up to 1HP Blower can be connected).
  • UV Lamp Relay O/P 230V AC / 2 A.
  • CF Lamp Relay O/P 230V AC / 2 A.
  • No. of blower failure indications 5.

buf on/off controller is used for on/off controlling of blower, uv lamp & cf lamp in dynamic pass boxes, bio safety cabinets and laminar air flow. The status of blower, uv lamp & cf lamp is provided on display.


features :

  • advanced micro controller based.

  • on/off message display.

  • relay o/p for blower (up to 1 hp), uv lamp & cf lamp.

  • on/off massage status indication with high intensity bar leds.

  • status indication: on, off-blower, on, off- uv lamp & on, off cf lamp.

  • blower failure status indications.

  • soft touch membrane key pad.

  • easy for installation.

























  • relay specifications contact material: silver alloy.
    contact rating: 230v ac / 2 a.
    no. Of operations
    mechanical:107
    electrical:105.
    enclosure ms powder coated for controller unit ss-316 face plate for dpm.
    mounting panel.
    power 100 - 260v, ac 50 hz.
    dpm dimensions 150mm l x 91mm w x 29mm d.


View Complete Details

Circuit Television Cameras

Closed - circuit television (CCTV) cameras can produce images or recordings for surveillance purposes, and can be either video cameras, or digital stills cameras.
View Complete Details

Cctv

Closed - circuit television (CCTV) cameras can produce images or recordings for surveillance purposes, and can be either video cameras, or digital stills cameras.

View Complete Details

Annunciation Modules

  • Operating Voltage 230VAC
  • Mounting Type Wall mounting
  • Output Type: 22mm RED and Green LED status indication for each channel.
  • Audible Indication: 24V Buzzer with manual override.
  • Enclosure: MS Powder Coated

Styrax manufactures microprocessor based Annunciation module to warn operator about utility failures such as temperature, RH and Differential Pressure parameters set point violations at central station.

View Complete Details

Access Control System

Access control is the process whereby movement in and out of a building is controlled through specific doors, elevators and even gates for specific people at specific times. This is needed when the areas are of high security where extra security is required beyond intrusion detection.

View Complete Details

Closed Circuit Camera

Closed - circuit television (CCTV) cameras can produce images or recordings for surveillance purposes, and can be either video cameras, or digital stills cameras.
View Complete Details

Electric Door Strikes

  • Brand Name Styrax Instruments
  • Voltage 12 V DC
  • Features Accurate dimensions, Precise finish, Hassle-free installation
  • Finish Type Polished
  • Thickness 100-120 mm
  • Face Plate Size 150x39.5x28 mm
  • Holding Strength 800 kg
View Complete Details

Air Shower Controller

5,000 - 20,000 /Piece Get Latest Price
  • Type Air Shower Controller
  • Voltage 230 V
  • Phase Three Phase
  • Frequency 50 Hz
  • Power Source Electric
  • Operating Temperature 0-100 deg C
View Complete Details

Ph Meters

  • Resolution 0.01 pH
  • Accuracy ±0.02 pH
  • pH Input Impedance > 1012Ω
  • Operating Temp 0 to 60°C (32 to 122°F)
  • Relative Humidity 95% @ 40 °C, non-condensing
  • Analog Output Non-isolated - fixed range 0-14 pH = 4-20mA

a ph meter is an instrument used to measure acidity or alkalinity of a solution - also know as ph. Ph is the unit of measure that describes the degree of acidity or alkalinity. It is measured on a scale of 0 to 14.


the quantitative information provided by the ph value expresses the degree of the activity of an acid or base in terms of hydrogen ion activity. The ph value of a substance is directly related to the ratio of the hydrogen ion [h+] and the hydroxyl ion [oh-] concentrations. If the h+ concentration is greater than oh-, the material is acidic; i.e., the ph value is less than 7. If the oh- concentration is greater than h+, the material is basic, with a ph value greater than 7. If equal amounts of h+ and oh- ions are present, the material is neutral, with a ph of 7. Acids and bases have free hydrogen and hydroxyl ions, respectively. The relationship between hydrogen ions and hydroxyl ions in a given solution is constant for a given set of conditions, either one can be determined by knowing the other.


styrax manufactures micro processor based ph meter is an economical, user-friendly panel meter for ph measurement. Its small size allows for easy installation and will accommodate any ph electrode with bnc connector. Temperature compensation is either manual or automatic with use of any 1000 platinum rtd.































emp. Compensation manual fixed resistors; automatic 1000 rtd
display 4 digit, red led, 14.2 mm h (0.56")
display range 0 to 14 ph
connections bnc
power requirements voltage:115 vac 15% standard (230 vac or 10 to 32 vdc optional) frequency:50 or 60 hz
power consumption 2.5 watts max.
View Complete Details

Gang Men Alarm System

  • Accuracy ±2minutes per year at 25°C.
  • Battery backup for RTC 3.6VDC Lithium-Ion.
  • Time format 24 Hrs
  • Operating Voltage 230VAC.
  • Output PFC output to connect external Siren

Styrax manufactures Gang man alarm system, this system used as siren to alert people who are working in particular area as per predefine set time intervals. This clock synchronized with wired master clock through RS485 to maintain clock with zero error. These clock displays time in 24Hrs format. Manual override and Manual ON/OFF pushbuttons are provided to control siren on demand basis.




  • 4 digit 7 segment 2 LED display to display Hours and Minutes.


View Complete Details

Fire Alarm System

A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station.

View Complete Details

Display Unit

  • Display 128x64 Graphical LCD
  • Input Type: Analog Inputs 4-20mA/0 - 10VDC RS485.
The STYRAX Data Logger has been specially developed keeping process measurement requirements of different locations in Pharmaceutical industries. The Data logger can measure, log and report process parameters like Temperature, Relative Humidity, Pressure, Vacuum, pH, etc. The data logger accepts data from either as analog inputs or RS485. 128x64 graphical LCD is provided to monitor process parameter and process violations. Built-in RTC provided to store data with real time and date stamp. Data transfers to any master device on MODBUS RTU RS-485 communication for remote monitoring. Data logger supports different types of units for process value data.
View Complete Details

Data Loggers

  • Display 128x64 Graphical LCD
  • No. of Channels: Supports maximum 48 channels
  • Input Type: Analog Inputs 4-20mA/0 - 10VDC RS485.
  • Keypad: Soft touch membrane keypad
  • Output MODBUS RTU, RS485

the styrax data logger has been specially developed keeping process measurement requirements of different locations in pharmaceutical industries. The data logger can measure, log and report process parameters like temperature, relative humidity, pressure, vacuum, ph, etc. The data logger accepts data from either as analog inputs or rs485. 128x64 graphical lcd is provided to monitor process parameter and process violations. Built-in rtc provided to store data with real time and date stamp. Data transfers to any master device on modbus rtu rs-485 communication for remote monitoring. Data logger supports different types of units for process value data.

View Complete Details

Temperature Controller

  • Feature Programmable channel ranges and unit selections. and Programmable resolution.
  • Measuring Ranges: Inbuilt Sensor: 0°C to 50°C. Analog Input: -199.9°C to 999.9°C.
  • Resolution: Temperature:0.1°C.
The STYRAX Temperature Controllers has been specially developed keeping process measurement requirements in Pharmaceutical industries. The Temperature Controller can measure Temperature Inbuilt integral Sensor, or analog input. The Temperature Controller has status LEDs for process violation indication, the process data transfers to any master device on MODBUS RTU RS-485 communication. It also communication diagnosis LED for SCADA communication. The controller has inbuilt buzzer for audible process violation. It has keypad to program and calibrate the instrument by user. It has Stainless steel Modular Face plate, which is designed as a mounting accessory for monitor suited for Brick and Modular wall for Clean Room applications where you need flush mounting mechanism.
View Complete Details

Flow Controllers

Styrax manufactures micro controller based Flow controller used to Turn OFF motors in dry run condition. By using this flow controller user can prevent motor failure due to motor dry run.

View Complete Details

Surgeon Control Panel

the styrax surgeon control panels (scp), sometimes called theatre control panels (tcp) or operating room control panels, are the central focus for infrastructure controls as well as alarms and information required in an operating room. This focus has two main benefits it allows the users to only have one familiar source of information and lets the facilities staff easily inspect and maintain several different subsystems, without disrupting the wall infection integrity.


features :

  • stopwatch timer.

  • real time clock.

  • temperature, rh and differential pressure display unit with in-built.

  • integral sensor.

  • differential pressure display unit with integral in-built sensor.

  • medical gas alarm system.

  • hands free telephone.

  • ot control switches.

  • wall or modular mounting.

  • ss-304 faceplate and ms powder coating backside box.

View Complete Details

Staticpass Box Interlocking System

We are offering staticpass box interlocking system.
Description: pass box is used for material transfer from one clean room to another clean room. It consists of a
rectangular box with two doors. The two doors are interlocked such that two doors cannot be open at the same
time, to prevent pressure losses and cross contamination.

our pass box controller achieve this by preventing simultaneous access of door by ensuring that when one
door for a pass box is open then other door is closed.
Before opening of door.

1. When door 1 is opened the display on the door 2 will indicate wait and at the door 1 the display will
indicate door open
2. When any of the door is kept open beyond a particular time say 10 min, a buzzer will be blown and the
display at the doors will indicate close door
3. When any door is opened the cf lamp is switched on, and the uv lamp will be switched off
4. Both doors are provided with em locks

2. Features:
advanced micro controller based.
supports maximum of 2 doors
supports electromagnetic lockselectric strikers
door status indication with high intensity bar leds
status indication: go, wait, door open, close door
buzzer output for door is kept open more than specified time from 2 to 30 min.

uv lamp controlling
o uv lamp on for both doors closed
o uv lamp off for both doors open

3. Specifications:
general
electromagnetic lock source : 24v dc 250 ma
door control by relay:
relays:
contact material : silver alloy.
contact rating : 230v ac 2 a.
no. Of operations : mechanical : 107 , electrical : 105.

enclosure:
pass box controller
enclosure type : power coating box
mounting : on service area

display module
enclosure type : ss-316l
mounting : panel

power supply:
power : 80 - 280v, ac 50 hz
wattage : 50w

environmental:
operating temperature : 0 to 500c.

4. Electromagnetic locks:
a magnetic lock is a simple locking device that consists of an electromagnet and armature plate. By attaching the electromagnet to the door frame and the armature plate to the door, a current passing through the electromagnet attracts the armature plate holding the door shut .the magnetic lock relies upon some of the basic concepts of
electromagnetism. Essentially it consists of an electromagnet attracting a conductor with a force sufficiently large enough to prevent the door from being opened.

5. Status indication on display panel :
go = indicate that person can access the door.
Wait = indicate that person cannot access the door.
Door open = indicate door is opened
close door = indicates that the door is opened more than specified time.

Additional Information:

Packaging Details : a) Micro Controller Based Controller with Switch Mode Power Supply : 1 No's
b) Push Button Stations with GO, WAIT, DOOR OPEN, CLOSE DOOR message display : 2 No's
c)Electromagnetic Locks 300lbs 24V DC :2 No's

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Ram Bandi (Styrax Instruments India Private Limited)
  • H.No: 2-77, Near Gajularamaram Chowrastha, Gajularamaram, Hyderabad - 500055, Jeedimetla, Telangana, India
  • Share us via