Our Products
in the process of material transfer from unclassified area to classified area pass boxes are used. The doors are interlocked such a way that doors cannot be open at the same time, due to which pressure losses and bacterial contamination doesn't takes place throughout the material transferring process. The prevention of simultaneous access of doors is been achieved by our pass box controller by ensuring that when one door for a pass box is open then other doors closed.
the styrax electronic status board has been specially developed keeping process measurement requirements of clean rooms in pharmaceutical industries. The process scanner can measure temperature, rh inbuilt integral sensor, differential pressure inbuilt sensor or three analog inputs or two analog inputs and inbuilt differential pressure sensor. It has on demand dew point display. The scanner has status leds for process violation indication. Rh, temperature and differential pressure will display individually and data transfers to any master device on modbus rtu rs-485 communication. It has individual communication diagnosis led's for scada communication and status application communication. The scanner has inbuilt buzzer for audible process violation. It has keypad to program and calibrate the instrument by user. It has stainless steel modular face plate, which is designed as a mounting accessory for monitor suited for brick and modular wall for clean room applications where you need flush mounting mechanism.
%RH | ±2% RH for 10 to 90% and±4% RH for remaining. |
Temperature | : ±0.3°C for 0°C to 50°C and 2°C for remaining. |
DP | ±1.5% for all units. |
Clock | ±0.5 Second (In case of communication with Master Clock) ±2 minutes per year (In case of communication failed with Master Clock) |
%RH | 1/0.1% RH |
Temperature | 1/0.1°C. |
DP | 0.1mmWC |
24VDC/24VAC. |
Model No. | Input Type | No. of Channels | Display | Dimensions |
---|---|---|---|---|
CRI105I | Inbuilt Sensor | 3 | 0.8" for Parameter and 0.56" for status display | 200 x 315 x 35 |
CRI105I | 4-20mA | 3 | -do- | 200 x 315 x 35 |
CRI105V | 0-10VDC | 3 | -do- | 200 x 315 x 35 |
buf on/off controller is used for on/off controlling of blower, uv lamp & cf lamp in dynamic pass boxes, bio safety cabinets and laminar air flow. The status of blower, uv lamp & cf lamp is provided on display.
relay specifications | contact material: silver alloy. contact rating: 230v ac / 2 a. no. Of operations mechanical:107 electrical:105. |
enclosure | ms powder coated for controller unit ss-316 face plate for dpm. |
mounting | panel. |
power | 100 - 260v, ac 50 hz. |
dpm dimensions | 150mm l x 91mm w x 29mm d. |
Closed - circuit television (CCTV) cameras can produce images or recordings for surveillance purposes, and can be either video cameras, or digital stills cameras.
Styrax manufactures microprocessor based Annunciation module to warn operator about utility failures such as temperature, RH and Differential Pressure parameters set point violations at central station.
Access control is the process whereby movement in and out of a building is controlled through specific doors, elevators and even gates for specific people at specific times. This is needed when the areas are of high security where extra security is required beyond intrusion detection.
a ph meter is an instrument used to measure acidity or alkalinity of a solution - also know as ph. Ph is the unit of measure that describes the degree of acidity or alkalinity. It is measured on a scale of 0 to 14.
the quantitative information provided by the ph value expresses the degree of the activity of an acid or base in terms of hydrogen ion activity. The ph value of a substance is directly related to the ratio of the hydrogen ion [h+] and the hydroxyl ion [oh-] concentrations. If the h+ concentration is greater than oh-, the material is acidic; i.e., the ph value is less than 7. If the oh- concentration is greater than h+, the material is basic, with a ph value greater than 7. If equal amounts of h+ and oh- ions are present, the material is neutral, with a ph of 7. Acids and bases have free hydrogen and hydroxyl ions, respectively. The relationship between hydrogen ions and hydroxyl ions in a given solution is constant for a given set of conditions, either one can be determined by knowing the other.
styrax manufactures micro processor based ph meter is an economical, user-friendly panel meter for ph measurement. Its small size allows for easy installation and will accommodate any ph electrode with bnc connector. Temperature compensation is either manual or automatic with use of any 1000 platinum rtd.
emp. Compensation | manual fixed resistors; automatic 1000 rtd | |
display | 4 digit, red led, 14.2 mm h (0.56") | |
display range | 0 to 14 ph | |
connections | bnc | |
power requirements | voltage:115 vac 15% standard (230 vac or 10 to 32 vdc optional) | frequency:50 or 60 hz |
power consumption | 2.5 watts max. |
Styrax manufactures Gang man alarm system, this system used as siren to alert people who are working in particular area as per predefine set time intervals. This clock synchronized with wired master clock through RS485 to maintain clock with zero error. These clock displays time in 24Hrs format. Manual override and Manual ON/OFF pushbuttons are provided to control siren on demand basis.
A fire alarm system is a set of electric/electronic devices/equipment working together to detect and alert people through visual and audio appliances when smoke/fire is present. These alarms may be activated from smoke detectors, heat detectors, water flow sensors, which are automatic or from a manual fire alarm pull station.
the styrax data logger has been specially developed keeping process measurement requirements of different locations in pharmaceutical industries. The data logger can measure, log and report process parameters like temperature, relative humidity, pressure, vacuum, ph, etc. The data logger accepts data from either as analog inputs or rs485. 128x64 graphical lcd is provided to monitor process parameter and process violations. Built-in rtc provided to store data with real time and date stamp. Data transfers to any master device on modbus rtu rs-485 communication for remote monitoring. Data logger supports different types of units for process value data.
Styrax manufactures micro controller based Flow controller used to Turn OFF motors in dry run condition. By using this flow controller user can prevent motor failure due to motor dry run.
the styrax surgeon control panels (scp), sometimes called theatre control panels (tcp) or operating room control panels, are the central focus for infrastructure controls as well as alarms and information required in an operating room. This focus has two main benefits it allows the users to only have one familiar source of information and lets the facilities staff easily inspect and maintain several different subsystems, without disrupting the wall infection integrity.
Additional Information:
Packaging Details : a) Micro Controller Based Controller with Switch Mode Power Supply : 1 No's
b) Push Button Stations with GO, WAIT, DOOR OPEN, CLOSE DOOR message display : 2 No's
c)Electromagnetic Locks 300lbs 24V DC :2 No's