  1. Relay Parts 12 Products available
  2. Test Kits 7 Products available
  3. Testing Equipment 5 Products available
  4. Power Supply System 4 Products available
  5. High Voltage Testers 4 Products available
  6. Transformers 3 Products available
  7. Auto Transformer 2 Products available
  8. Voltage Transformers 1 Products available
  9. Test Bench 1 Products available
  10. Voltage Measuring Instruments 1 Products available
  11. Electronic Transformers 1 Products available
  12. Power Converter 1 Products available
  13. Inverters 1 Products available
  14. Decade Boxes 1 Products available
  15. Measuring Instruments & Equipment 1 Products available
  16. Digital Analyzers 1 Products available

Relay Parts

Our offered Product range includes C-50 Secondary Injection Over Current Relay Test Kit, CV-30 Secondary Injection Over Current Relay Test Kit, CV-10 Secondary Injection Over Current Relay Test Kit, SI/MCCB -1000-2000 MCCB Test Kit and SI-RCCB ELCB/RCD/RCCB Test Kit.

C-50 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Channels 2
  • Material MS
  • Model SI / C – 100 & SI / C – 50
  • Input 220V, 50Hz, 1Ph

Features

Features and performance similar to the types SI / CV- 50 and CV – 100, except that there is no provision of Auxiliary AC / DC outputs.

 

Dimensions

  • 425 x 390 x 280 mm, Wt. 28 Kg for SI / C-50
  • 495 x 450 x 300 mm, Wt. 35 Kg for SI / C-100

 

Specification

  • Type SI / C – 100 : AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 100A on 3VA burden relay
  • Type SI / C – 50 : AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 50A on 3VA burden relay.
View Complete Details

CV-30 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Material MS
  • Dimensions 610 x 420 x 185 mm
  • Weight 25 Kg
  • Input 230V, 50Hz
  • AC Injection Current 0.01 - 30 Amps ( 60 Secs)
  • Aux. AC / DC Output 0 – 250v AC, 2A , 0 – 300v DC, 2A
  • Model Type SI / CV - 30 (Brief Case model)

Features

  • Assembled in VIP brief case.
  • Undistorted Sine wave Injection current.
  • Selection of either Current Injection or Auxiliary AC / DC output .
  • Digital ammeter and timer but no provision of AC / DC Voltmeter, which is to be measured externally.
View Complete Details

CV-10 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Material MS
  • Dimensions 470 x 365 x 170 mm, Approx
  • Weight 12.5Kg
  • Model Type SI / CV - 10 (Brief Case model)
  • Input 230V, 50Hz
  • AC Injection Current 0.01 - 10 Amps ( 60 Secs)
  • Aux. AC / DC Output 0 – 250v AC, 0.75A, 0 – 300v DC, 0.5A

Features

  • Assembled in VIP/Aristocrat make moulded brief case.
  • Sine wave Injection current.
  • Selection of either Current Injection or Auxiliary AC / DC output .
  • Digital ammeter and timer but no provision of AC / DC Voltmeter, which is to be measured externally.
View Complete Details

SI/MCCB -1000-2000 MCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Availability 52Kg
  • Model SI / MCCB - 1000/2000
  • Material MS
  • Dimensions 500 x 440 x 380 mm
  • Input 230V, 50Hz

Feature

Variant of Primary Injection kit SI / PIK but with provision for 4 digit auto ranging digital time interval meter.

 

Output

  • 3V / 1000Amp or as specified (1 min. rating) For SI / MCCB – 1000
  • 3V / 2000Amp or as specified (1 min. rating) For SI / MCCB - 2000
View Complete Details

SI-RCCB ELCB/RCD/RCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Availability 7 Kg Apx
  • Model SI / RCCB
  • Dimensions 230 x 315 x 95 mm
  • Material MS
  • Input 230V, 50Hz
  • Output Mode 1 10 – 60mA for Domestic range
  • Output Mode 2 100 – 500mA for Industrial range

Features

  • Ideal for both Domestic and Industrial types.
  • Not suitable for DC systems and unearthed networks
  • mA Current Display with DPM – modules.
  • Range selection for 10 – 60mA / 100 – 500mA residual current.
  • Inexpensive, light weight, handy

 

Application

  • Testing of ELCB / RCD / RCCB
  • ELCB – Earth Leakage Circuit Breaker.
  • RCD - Residual Current Device.
  • RCCB – Residual current circuit breaker.
View Complete Details

2 In 1 SI/MCCB -1000-2000 MCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Availability 52 Kg
  • Material MS
  • Model SI / MCB-MCCB 100 / 1000 / 2000 - (2 in 1)
  • Dimensions 500 x440 x 380 mm
  • Input 230V , 50Hz Single phase

Features

  • Mains Isolated single phase AC Injection Currents.
  • 2 in one test kit to test miniature circuit breaker (MCB) / Bimetal O/L relays up to 63A as well as molded case circuit breakers (MCCB) of upto 500 Amps.
  • Mode selector switch for MCB or MCCB testing.
  • Auto ranging digital Time Interval meter.
  • Compatible for NO / NC auxiliary trip contact selection.

 

Application

On- Line Production / Field or site testing of

  • Miniature Circuit breakers (MCB).
  • Bimetal Overload relays.
  • Moulded case circuit breakers (MCCB).

 

Output

Mode 1 : 0.01 to 100 Amp AC for MCBs

Mode 2

  • 100 to 1000 Amp AC for MCCBs
  • 100 to 2000 Amp AC for MCCBs
View Complete Details

MCB Bimetal Overload Relays Test Kit

  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Availability 33 Kg
  • Model SI / MCB – 100 & SI / MCB – 200
  • Dimensions 320 x 250 x 135 mm
  • Input 230V, 50Hz

Features

  • Mains isolated, distortion less sine wave AC injection current
  • Light weight and easily portable for “ ON – site” testing.
  • Compatible for NO / NC auxiliary trip contact selection.
  • Front panel equipment protected against mechanical damage with lockable cover.
  • 4 digit auto ranging Time Interval meter.

 

Output

Mains isolated A.C. Injection current continuously adjustable

  • From 0.01 Amp to 100 Amps . for SI / MCB - 100 ( 3 minutes rating)
  • From 0.01 Amps to 200Amps . for SI / MCB - 200 ( 3 minutes rating)
View Complete Details

PIK-5 Primary Injection Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Frequency 50
  • Model 5 & SI / PIK - 10 , (SI / PIK - 10T with extra timer)
  • Applications CT ratio testing, Primary injection relay testing
  • Input 220V to 240V, 50Hz , 1Ph

Features

  • Self contained fully integrated unit comprising MCB, Variac, Isolated wound Secondary Injection Transformer, Dual ratio C.T., and Digital Ammeter.
  • Input with 3 pin metal clad plug and socket.
  • Copper Bus bar output.
  • Push button operated Contactor with optional timer
  • Powder coated ms enclosure with front panel protection by a lockable cover.
  • Transportable on castor wheels.

 

Dimensions

  • 450 x 420 x 345 mm, Wt: 32 Kg. For 5 kVA unit
  • 580 x 590 x 420 mm, Wt: 66 Kg. For 10kVA unit

 

Output

  • 0 – 5V / 1000A ( 60 sec. Rating)
  • for 5 KVA unit – SI / PIK - 5
  • 0 – 5V / 2000A ( 60 sec. Rating)
  • for 10 KVA unit – SI / PIK -10
View Complete Details

PIK-20 Primary Injection Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Capacity 2000A
  • Frequency 50
  • Dimensions 720mm X 625mm X 690mm
  • Weight 96kg
  • Input 220V or 440Volts 50Hz
  • Model SI / PIK – 20 & SI / PIK - 15 (SI / PIK-15T with extra timer)

Features

  • Self contained fully integrated unit comprising MCB, Variac, Isolated wound Secondary Injection Transformer, Dual ratio C.T., and Digital Ammeter.
  • Input with 3 pin metal clad plug and socket.
  • Copper Bus bar output.
  • Push button operated contactor with optional timer Powder coated ms enclosure with front panel protection by a lockable cover.
  • Transportable on castor wheels.

 

Output

  • 0 - 5V / 2500A ( 60 sec. Rating) ( SI/ PIK 15)
  • 0 - 4V / 3000A ( 60 sec. Rating) ( SI/PIK 20)
View Complete Details

With Timer ELCB/RCD/RCCB Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulations
  • Country of Origin India
  • Availability 10 Kg Apx
  • Model SI / RCCB – T (With Timer)
  • Dimensions 230 x 315 x 95 mm,
  • Input 230V, 50Hz
  • Output Mode 1 10 – 60mA for Domestic range
  • Output Mode 2 100 – 500mA for Industrial range

Features

  • Unit packed inside a VIP/Aristocrat suitcase.
  • mA Current LCD/LED display with DPM module.
  • 4 digit electronic timer with LED display to record trip time.
  • Ideal for both Domestic and Industrial types.
  • Not suitable for DC systems and unearthed networks.
  • Range selection for 10 – 60mA / 100 – 500mA residual current.
  • Inexpensive, light weight, handy.

 

Application

  • Testing of ELCB / RCD / RCCB
  • ELCB – Earth Leakage Circuit Breaker.
  • RCD - Residual Current Device.
  • RCCB – Residual current circuit breaker
View Complete Details

CV-200 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Number Of Flower Secondary Injection Relay Test Kit
  • Country of Origin India
  • Material MS
  • Model Number Type SI/CV - 200
  • Dimensions 530 x 510 x 570 mm, approx
  • Weight 59 Kg
  • Applications Secondary Injection Testing of StaticOver current/ Earth fault relays/ Electromagnet (CDG) relays
  • Input 220 – 240 V, 50Hz, 20 Amps
  • AC Injection current Isolated from Mains (60 Secs. Rating) Continuously adjustable from 0.01 – 200 Amps
  • Auxiliary Ac & Dc supply 0- 250 Volts, 0.5 Amps with only Dc Volt meter

Features

  • Undistorted Sine wave Injection Current.
  • Performance comparable to Alstom’s CFB Test kit.
  • Simultaneous availability of AC Injection Current and auxiliary AC / DC outputs.
  • Digital Panel meters for Volt / Amp / Timer.
  • Suitable for both NO / NC trip contacts of Relays under test.
  • Input overload protection with MCB for Current Injection and 0.5A glass fuse for Auxiliary AC/DC outputs.
  • Powder coated ms enclosure, portable with lifting handles and front panel protectionwith a lockable hinged cover.

 

Note : As the combined Ac & Dc voltmeter is not available, any one voltmeter ie. Either Ac or Dc voltmeter will be fitted to the test kit.

View Complete Details

CV-100 Secondary Injection Over Current Relay Test Kit

  • Min. Order (MOQ) 1 Piece
  • Brand Name Sudharsan Insulation
  • Country of Origin India
  • Material MS
  • Frequency 50
  • Model Number SI / CV – 50 & SI / CV – 100
  • Input: 220V, 50Hz, 1Ph
  • Applications Secondary Injection Testing of Static-Over current/Earth fault relays/Electromagnet (CDG) relays

Features

Undistorted Sine wave Injection Current.

  • Performance comparable to Alstom.s CFB Test kit.
  • Simultaneous availability of AC Injection Current and auxiliary AC / DC outputs.
  • Digital Panel meters for Volt / Amp / Timer.
  • Suitable for both NO / NC trip contacts of Relays under test.
  • Input overload protection with MCB for Current Injection and 0.5A glass fuse for Auxiliary AC/DC outputs.
  • Powder coated ms enclosure, portable with lifting handles and front panel protection with a lockable hinged cover.

 

Dimensions

  • 425x390x280mm, Wt 28Kg for CV- 50
  • 560x450x300mm, Wt 42Kg for CV- 100

 

Specification

Type SI / CV – 100

AC Injection Current - Isolated from mains (60 sec rating), continuously adjustable from 0.01 to 100A on 3VA burden relay.

Auxiliary output - continuously rated, non isolated from mains

  • 0 – 250V, 0.75 A AC
  • 0–300V, 0.5A DC

 

Type SI / CV – 50

AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 50A on 3VA burden relay.

Auxiliary Output –continuously rated, non isolated from mains

  • 0 – 250V, 0.75 A AC
  • 0–300V, 0.5A DC
View Complete Details