Our Products
The rugged industrial design is made by Piezo-resistive stainless steel sensor and also available in intrinsically safe model forhazardous area(EEx ia IIC T4). The system pressure is shown on the 4-digit LED display, in addition the display supports programming using the foil keys; available one analogue output (4-20 mA or 0-10V) and 1 or 2 independent PNP contacts. The display and housing are rotatable, so that the position of the display can be adapted to unusual installation positions and pressure ranges selectable from -1 to 600 bar (gauge/abs), accuracy available 0.5%/0.35%/0.25% of F.S. Process connections can be chosen from different sizes. It can be used with any gases or liquids compatible with
SCREW IN TRANSMITTER
CHARACTERISTICS
Pressure port G 3/4" flush for pasty and impurified media
Pressure port PVDF for aggressive media
OPTIONAL VERSIONS
IS-version (only for 4 20mA / 2 --- wire) :Ex ia = intrinsically safe for gases and dusts
SIL 2 application according to IEC 61508 / IEC 61511
RANGE:0 to 60 BAR
APPLICATION
Plant and Machine Engineering
Energy Industry
Environmental Engineering (water --- sewage --- recycling)
Medical technologies.
APPLICATION :Cooling Water & Lubricating Oil
FEATURES :
Flow Rate up to 400 lpm.
Various Process connections (" / " / " / " BSP M)
Different Line sizes (DN 8 /10 / 20 / 25 / 32 / 40 / 50)
Maximum working pressure up to 25 bar
Maximum Working temperature 110C
Type: Inline / Insertion / Inline with PVC Pipe section.
Adjustable Switching Point
Low Pressure Drop
Instant Response
High Repeatability
Material: Brass / Stainless Steel / PPO Noryl GFN3.
Diameter: 19 / 27 / 35 mm
Level measurement in water, fuel and diesel oil
Nominal pressure ranges from 0 - 1 mWC up to 0 - 250 mWC
Available in Stainless Steel & Ceramic Sensors.
The submersible level transmitter has been designed for continuous fluid level measurement in water and clean to slightly contaminated media. Housing material is 1.4571 (316Ti); the sensor diaphragm is made of 1.4435 (316L). Standard sealing material is FKM; other materials are available on request. Due to the high-value piezoresistive stainless steel sensor the submersible probe LMP 307 features an excellent linearity and good long term stability. On the basis of the excellent metrological features of the stainless steel sensor, it is possible to manufacture the submersible probe with accuracy of 0.05% FSO BFSL also. In addition, the several cable materials (PVC, PUR and FEP) the customer has the possibility to consider different versions of cable protection with different lengths.
APPLICATION :
Environmental engineering: water supply, sewage treatment
Depth or level measurement in wells and open waters
Ground water level measurement
Level monitoring in open tanks
CHARACTERISTICS :
Small thermal effect
Excellent linearity
Good long term stability
Output: 420 mA & 010 VDC, 2/3-wire
Accuracy:0.175 / 0.125 / 0.05% FSO BFSL
(0.35 / 0.25 / 0.1 FSO IEC 60770)
Option Ex version : (only with 4 -20 mA / 2-wire) ATEX 2006 X
Option cable protection with corrugated pipe.
FEATURES:
Easy & reliable methods to monitor fluid levels
Proven float principle
Nominal Pressure PN 25
Maximum temperature 110C
Easy side installation using threads " or " BSP
Potential - free contact at signaling transmitter
Type of protection IP 65
Type of Materials: Brass, Stainless steel, Plastic.
Maximum Contact Rating : Max.1A, 230 Vdcor 48 Vdc, 26 VA or 20 W
CASINGS
Aluminum, V-shaped, completely polished, gold-colored anodized (or silvercoloured upon request). Numerals of reading scale printed on the right side. Printing black-colored for easy readability. Adjustable to any desired viewing position and locked by brass nut, spanner size 22 mm. Angle thermometers (90) have a grooved adapter piece with set screw.
ADVANTAGE:When mounting the thermometer, it is not necessaryto turn the casing.
GLASS INSERTS (CAPILLARIES)
Capillary tube of solid glass, bar-shaped, prismatic (optic enlargement of the column), diameter approx. 6mm, oval opening, with yellow background for mercury and white background for blue fluid column. Calibration is deeply burnt, in black, thus being absolutely resistant.The main graduations, which correspond with the printing on the casing, are especially clearly outlined.
THERMOMETER EXECUTION
straight
Angle 90, backwards
Angle 135, backwards
Temperature Ranges: -60 to + 600C
Division: C, F
Columns Filling: Blue Fluid upto 200C & Mercury above 200C
Immersion Tube Length : 63 mm, 100mm, 160mm, 250mm, 400mm
Thread Connection : G , G , M20 x 1.5, M27 x 2
Immersion Tube Material : Brass, Stainless Steel
ACCURACY
About 1 % of maximum scale value, for thermometers with mercury column.
The accuracy of thermometers with an alcoholic fluid meets DIN 16 195 requirements and, consequently, corresponds with the requirements for local reading thermometers.
FEATURES:
Programmable sensor inputs enable the simple connection of numerous sensors Up to 5 alarm outputs (relay, SSR or norm signal).
2- or 3-point controller, 3-point-step controller as well as PID controller.
Safe heater break function.
Digital control inputs for external set point setting.
RS 485 interface, MODBUS protocol.
Programming adapter for easy transfer of operating data.
AUTOTUNED , MICROPROCESSOR BASED DIGITAL CONTROLLER
PID control function
2- and 3-point control function
3-point-step control
MEASURING INPUTS
Resistance thermometer Pt100
Semiconductor PTC / NTC
Thermocouples J, K, S, B, E, L, N, R, T, C
Voltage signals 0.50 mV, 0.60 mV
NORM SIGNALS
4.20 mA
0.10 V
OUTPUTS
Max. 4, up to 2 x control- resp. 3 x alarm-output possible
Relay SPST 5 A / 2 A / 250 Vac
SSR drive 14 Vdc/ 7 mA (20 mA)
NORM SIGNALS (CONTROL OR SIGNALS)
4.20 mA
010 V
DISPLAY
4-digits 7-segment LEDs 2-lines Process value red, 7 mm high Set value green, 7mm high.
FUNCTIONS :
Air Velocity & ambient temperature
Selection of units
Hold Function
Min & Max Values
Automatic average
Air flow calculation with cone
Adjustable automatic shut-off
Adjustable backlight
Detection of flow direction
Measuring Ranges: Air Velocity: 0.8 to 35 m/s
Air Flow: 0 to 99999 m3/hr
Ambient temperature: -20 to +80C
Display: 2-line LCD display
Power supply : 1 alkaline battery 9V 6LR61
Operating temperature (instrument) : from 0 to 50C
Operating temperature (probe) : from -20 to +80C
Weight : 190g
FEAUTURES :
(1) Configuration of max. 60 channels via inputs, outputs.mathematical /logical functions, controller, profiles or virtual outputs
(2) Allocation of clogged channels in 10 groups (max.6 channels per group)
(3) Connection of channels Via mathematical logical functions
(4) 8 Integrated PID controller
(5) Datalogger of max.60 channels
(6) Free selectable measuring rate (max.10 Hz)
(7) Extensive Trigger function
(8) Internal Memory 1.5 GB
Inputs : 4.10 V + 4.20 mA
Output : 8 relays / 4.20 mA (Analogue Output)
Transmitter Supply :24 Vdc 5% max.200 mA
Communication Interface : RS-485 (Modbus RTU), Master / Slave
Display : 3.5" TFT Touchscreen, graphics capable, coloured (16-bit), 320 x 240 pixels.
Housing:Panel Mounting.