Operation Theatre Control Panel

The surgeon control panel shall meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations. The Surgeons control panel shall be designed to cope with changing technology & equipment in operating environments. Control Panel is user friendly & eases to operate. The panel is Membrane type; configured to incorporate all the services that operation room staff required. The fascia is made of superior quality UV resistance membrane with sterilization feature
View Complete Details

Window Motorize Blinder

Double insulated fixed glazing with not less than 5mm thick toughened glass. Window frame is powered coated Alumunium of approved shape flush mounted with wall paneling. Electrical Blinds Motorized horizontal Blinds of powder coated Aluminum strips or equivalent of approved shade including necessary accessories. The motor is of imported brand having switch to Control the blinder.
View Complete Details

Hermetically Sealed Sliding Doors

The door frame is made of high quality anodize aluminum and the door panel are made of compact laminate that It can withstand high abrasion. To ensure efficient sealing of the doors, frames are provided. They will consist of reinforced plasterboard panels faced with the same laminate as of door. The door seals of all four edges in the closed position & shall be surface installed type. The track of the door is constructed with high quality door lock with aluminum extrusion, fixed firmly to the walls. Nylon runner guides shall be fixed to the door in such a way they do not obstruct trolley movement through the door. The door frames shall be edged with an aluminum extrusion & with concealed fixings that are adjustable during installation to ensure a 100% hermetic seal is achieved. Vision panels, 300mm X 300 mm is provided in the doors. The door controller shall be sensing overload condition and in overload case the door will automatically stop & reverse the direction of travel. The controller shall be capable of either being operated by elbow switchesfoot switches, radar switch (touch less sensor). All doors will be operated easily manually in the event of failure of the power supply or the automation unit.
View Complete Details

Swing Doors

The swing doors provided by us are subjected to stringent quality checks during the entire manufacturing and delivery procedure to guarantee premium quality and high performance. The swing doors supplied by us are fabricated from optimum quality steel and are available in single or double panel options. These easy to install, operate and maintain doors. Door Stainless Steel 304, 202 or HPL Sink also Available. Door Sealed inside Open able Flush Door of size available 1500 X 2100 mm, 1200 X 2100 mm, 900 X 2100 mm and also non stander in size can be made. Door leaf having viewing window on both the shutters of sizes 300X300mm. The Door frame is made of Extruded Alumunium Profile having Gasket to provide Leak less mechanism on three side, the door will have drop seal to provide sealing against the floor. Door will have auto door closer, D type Handle and Cylindrical Door lock System.
View Complete Details

Medical Gas Regulator

We offer high efficacy Medical Gas Control and Automatic Changeover, which is highly acknowledged in the national as well as international markets. We have firmly positioned ourselves as one of the overruling central pipeline for Oxygen Supply System in India. Made as per international standards, our Oxygen Supply System is highly demanded due to its distinctive features mentioned below :
View Complete Details

Electrostatic Dispersive Vinyl Flooring

It results in low accumulation of electrostatic charges to people & equipment.Provides an enduring resistance to static and dynamic loads.Displays excellent resistance to chemical products such as detergents, acids and alkaline products with carrying Low VOC emissions.Has Fungi-static and bacteriological treatment throughout the total thickness of flooring.It is non-absorbent, impervious and non-porous.
View Complete Details

Surgical Scrub Stations

Compact surgical scrub sink should be designed for use in OT complex providing Surgeons with a convenient sink for pre OT scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel and should be seamless welded construction, polished to a stain finish. The scrub sink should be provided with a front access panel which should be easily removed for access to the water controlled value, waste connections, stoppers and strainers. Hands free operation should include infra red sensors with built-in range of adjustment. Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature. User defined setting of 1, 3, 6 to 10 min are available. This timing should be adjustable to meet individual application requirements. Provided with infrared sensors, thermostatic control taps with fail safe temperature controls. All units should have reduced anti- splash fronts. Foot operated switch should be there.Scrub Station also Make in DuPont Make Solid Surface Also, with all common future of SS 304, 2 bay or 3 bay Station. Provide knee action or infrared sensor or both in Stainless Steel versions, thermostatic controls with fail-safe temperature controls, scrub Sink is provided with front access panel for maintenance and repairs
View Complete Details

Area Valve

Area Valve Service Unit are mainly used in Medical Gas Pipeline System of individual zones without disturbing the gas flow to other zones. In case of emergencies, Area Valve Service Unit can also be used to shutoff gas distribution to individual zones. A single box can hold from 1 to 6 valves, allowing control of 6 types of gases. All boxes are factory-assembled with the smallest valve on top, largest on bottom. Area Valve Service Unit are mainly used in Medical Gas Pipeline System of individual zones without disturbing the gas flow to other zones. In case of emergencies, Area Valve Service Unit can also be used to shutoff gas distribution to individual zones. A single box can hold from 1 to 6 valves, allowing control of 6 types of gases. All boxes are factory-assembled with the smallest valve on top, largest on bottom.
View Complete Details

Storage Unit

The storage unit can be made with 1.50 mm thick EGP Zinc coated steel panels, Stainless Steel panels, High pressure Laminate panels. The storage unit will be divided in 2 equal parts and each part will have individual glass doors with high quality locking system. Each part will be provided with glass racks.
View Complete Details

Medical Gas Manifold Systems

  •  Material Brass
  • Types Manifold per point 10 gauge without Non Return Valve and Copper Tail Pipe connection, Flexible tail pipe connection (Oxygen / Nitrous- oxide / Carbon dioxide) – Supreme Model

Medical Gas Manifold Systems used for to connect the Supply source of Oxygen Nitrous Oxide Carbon dioxide and build the bank of cylinder of gases. Manufacturer & Retailer of Manifold System. Our product range also comprises of ICU Pendants, Bed Head Panels and Oxygen Flow Meters.

View Complete Details

Laminar Air Flow System

Air & Light Integrated laminar air flow ceiling: Plainair Ceiling System-constructed out of 1.6 mm thick aluminum sheet, The HEPA filters having dust spot efficiency of 99.99% 0.3 micron. Air & Light diffuser made out of two layer of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air. Plenum Box made of Alumunium or Steel, The Air & Light diffusers consist of two layers of monofilament precision woven polyester of uniform porosity with an open area of sufficient resistance to create laminar flow from diffuser face. Diffusing air into the theater uniformly over the total area, range of ventilated ceiling provides the sterility and cleanliness required for modern operating theater environment. Integral lighting provides an illumination level in excess of 15000 Lux in Operating area and 10000 lux other electronic stepless dimming down to 5% without flicker, It also provides a diffused shadowless lighting system with Intensity control.MINI PLEAT HEPA Plenum: Laminar Air flow Planair Ceiling System-constructed out of 1.6 mm thick Aluminum, SS 304 or GI sheet, having 6 or 8 nos of HEPA fileters. The HEPA filters having dust spot efficiency of 99.99% 0.3 micron. SS 304 diffuser for the plan air ceiling to give a "LAMINAR FLOW" of filtered air.
View Complete Details

Alarm Systems

Analog Gas Alarm Systems come in 1, 2, 3, 4, 5, and 6 gas categories where the number indicates the number of gases the system can handle. The system contains analog meters for displaying pressure of the different gases coming from the pipe lines. The system generates appropriate alarm in case of High pressure or Low Pressure in any gas. These alarms come with RS-485 Modbus interface for BMS connectivity. One NONC terminal is built-in for alarm extension and provision is made for adding external NONC interface for each gas individually.
View Complete Details

Hatch Box

A hatch box is provided by us to remove waste materials in whole area of hospital like in operation theatre and all over the dirty linen areas. Each hatch box is equipped with two doors and the doors are operated electronically and it is designed like that only one door should be opened at single time. the uv light (ultraviolet light) is installed in every hatch which is designed like that it is kept on during closing of both doors and it will automatically turn off in case of opening any single door also. It has indicators also on the both side of ot so that every status of open and close can be monitored from the both sides.
View Complete Details

Medical Gas Terminal Outlet

  • Feature Gas /Vacuum specific internal components, Non-interchangeable specific gas / vacuum probes etc.
  • Range Front Loading Double Lock German Outlet, Front Loading Round Type BS Standard Outlet etc.
We have firmly positioned ourselves as one of the distinguished Medical Gas Terminal Outlet suppliers in India. Our Terminal Outlets are precisely designed to perfection to provide excellent performance. Hospital Terminal Outlets offered by us are completely leak proof, safe and easy to operate.
View Complete Details

Surgical Suction Unit

We provide high efficiant Surgical Suction Unit, which is available with two Unbreakable Poly Carbonate Collection Jars each with a capacity 2000ml. Due to some of the following salient features, our Medical Suction Unit has achieved a distinct edge in the global market.
View Complete Details

Bed Head Panel

  • Features Simple to operate, Sturdy construction, Precise components, Easy to maintain etc .
We offer a wide range of high tech Bed Head Panel that includes Vertical Bed Head Panel as well as horizontal bed head panel. Bed Head Panels offered by us are available in Aluminum Mild Steel Powder coated with provision for Gas Outlets & Electrical 515 Amps switch sockets. As per the demand of the clients, our bed head panel is offered with Nurse Call cutout. We are counted among the distinguished Bed Head Panels Exporters and Suppliers based in India.
View Complete Details

Writing Board

Magnetically skin of white writing board for to note any important note during surgical period. Size: 948 x 648 x 55 mm. One operating list board should be provided in each operating theater. It should be made of ceramic having Magnetic properties and should be flushed to the wall of the operating room.
View Complete Details

X-ray Viewing Screen

  • Product Range C.F.L
  • Product standard X-ray confirms to Clean Room standard NEN EN 3134 and ISO 14644-4 Automation as per EN , IEE
The system has electrical safety codes for high & low voltage system. The theater is to be equipped with a 2 plate X-ray viewing screen. It is designed to provide flicker free luminance for the film viewing purpose. It is installed flushed with theater wall for hygienic and ease of cleaning purpose. The X-Ray viewing screen is designed for the purpose of front access. It is illuminated by 4 pieces of high frequency fluorescent lamps and the dimming is controlled by the usage of dimming ballast with the PCB that is mounted inside the box. The diffuser enables to diffuse the light evenly and to provide enough luminance for film viewing. It is made of high quality opaque acrylic sheet. The film is holded firmly by using spring loaded clips for ease of mounting and demounting. The body is built by using electrolyzed steel with powder coating.
View Complete Details

Pressure Relief Damper

Pressure relief dampers should be provided in each room to prevent contamination of air from clean and dirty areas. Suitably sized air pressure relief damper should be strategically placed, enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty areas. Counter- weight balancing system should be provided in the PRD to maintain positive pressure inside the operation room. Air pressure stabilizers should have unique capability of controlling differential pressure to close tolerance. The PRD should remain closed at pressure below the set pressure and should open fully at pressure and should open fully at pressure only fractionally above the threshold pressure. The body should be epoxy powder coated as per standard BS colors. First class electrolyzed steel plate should be used for body and with high grade SS304 stainless steel for blades.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Narendrasinh Charan (United Medical Engineers Systems)
  • Plot No. 80, Vibrant Industrial Park, Near ZAK GIDC AT Vahalal, Ta Daskroi, Memnagar, Ahmedabad, Gujarat - 380052
  • Share us via
  • Call 08069247292 Ext. 402