Our Products
We are leaders in the market for providing best range of 3 Phase Precision Power Analyzer VPA 60080 and LED Testing Power Analyzer
veer power analyzer vpa-60080 is result of continuous r & d activities. It is an accurate instrument to test 3 phase & 1 phase electrical machines due to high sampling rate & simultaneous measurement of parameters. It has no adjustable components inside so, accuracy remains long time. We provide free software veer power analyzer tool with vpa-60080 to communicate with computer which is capable to collect all parameters form vpa-60080 & generates test report. You can see parameters in different view like digital, analog , graphical etc in real time. You can record test data in real time to eliminates human error in testing.
| GENERAL SPECIFICATIONS | |
| Warm up time | 30 minutes |
| Operating temperature | 5°C to 50°C |
| Operating humidity | 20% to 80% RH (no condensation) |
| Storage temperature | 0°C to 55°C |
| Power supply | 160V - 290V @ 50Hz / 100V - 140V @ 60 Hz |
| Power consumption | 30VA Max. |
| Dimension | 376 x 320 x 145 mm (W x D x H)** |
| Panel cut out size | 332 x 133 mm without Feet** |
| Weight | 5.5 kg approximately** |
| Input Terminal Type | Voltage : Banana socket (wire fit type) |
| Current : large binding Post (1/ 4" or 6/16" copper stud with insulated nut) | |
| INPUT SPECIFICATIONS OF EXTRA CHANNELS | ||
| Parameter | Measuring Range | Accuracy / Remark |
| Flow, Pressure | 4 - 20 mA | ±0.20 % on FSD |
| Torque, RPM | Depends on Sensor | ±0.20 % on FSD |
| MEASUREMENT FUNCTIONS | |||||||||
| Parameter | Voltage / Current / Active power | ||||||||
| Accuracy ( within 1 year after Calibration*) Conditions: - Temperature : 25°C±5°C Humidity : 30 - 75% RH Input waveform : Sine wave Power factor : 1.0 Display digits : 5 / 6 digits Sample AVG : 8 Sample * For normal testing & input conditions |
|
||||||||
| Additional PF effect on active power measurement | At 50Hz 0.035" or Time delay errors 2.5 µS | ||||||||
| Effective Input range | 10-100% of Voltage, 1-100% current range rating | ||||||||
| Display updating value | 0.25 to 10 seconds selected By Models. | ||||||||
| Frequency Measurement | For >=Input > 3% of V1 from 30 to 800Hz Accuracy ±0.05% Frequency Between V1 Input & Neutral Terminal |
||||||||
VEER Power Analyzer VPAe is result of Continuous R & D activities. It Is an accurate Instrument to test 1 Phase electrical Machines due to high sampling rate & simultaneous measurement of parameter. It has no adjustable componenets inside so, accuracy remains long time.