The purpose of this panel is to monitor and maintain the power factor at HT side of the transformer.
The Banks are switched automatically with Vacuum Contactor.
This is mainly useful to minimize the Line losses as well as Transformer losses.
Key Features:
The Active Harmonic Filters offered by us guarantee highly effective compensation even in the presence of highly asymmetrical loads.latest technology to eliminate harmonic injected into the mains supply by non linear loads, as well supplies inductive power demanded by the load, so as to correct input power factor to near unity.
Ratings available
Working Principle of Low Frequency Electrode less Induction Lamp
Salient Features :
Comparison of Some Important Factors Induction Lamps Instead of Traditional Lamps Energy Saving and Maintenance Cost Saving upto 45%
Concept of Induction Lamp :An Induction Lamp is an Electrode-Less Fluorescent Lamp. Without electrodes, the lamp relies on the fundamental principles of electromagnetic induction and gas discharge to create light. When the low frequency supply applied then the current flows through the energizing coils wrapping around the ferrite cores, inductive electric field is produced around a gas-filled glass tube and the gas is discharged. The discharge path forms a closed loop causing acceleration of free electrons, which collide with mercury atoms and excited electrons from these atoms fall back from this higher energy state level, they emit ultraviolet (UV) radiation. The UV radiation created is converted to visible light as it passes through a phosphor coating (Fluorescent Powder) on the surface of the tube. Thus Light is produced. The elimination of filaments and electrodes results in a lamp of unmatched life. Lasting 100, 000 hours.
PCC/MCC panels are made up of 14/16 SWG CRCA material semi bolted structure firmly supported. Ensures desired breaking capacities, temperature rise & IP protection. Enough Space for incoming & outgoing Cable termination. Outgoing terminals are stud type as standard practice. All starters are Type Two Co-ordinated. CT terminals, Cable Alley Illumination Lamp, Space Heaters with Thermostats are standard features of our Panel boards
We are engaged in manufacturing and supplying superior quality Power control center. These Panels are widely demanded by the customers owing to their best quality competitive rates . The panels offered by us are manufacturing using the premium quality raw material to ensure the durability . This will achieving maximum satisfaction of the customers.
Features:
Available with copper or aluminium winding
Vacuum-impregnated for low-noise operation and corrosion-protection
Special low-loss Iron core of high-class transformer sheets for minimized heat losses
High linearity rating safe against ferro-resonances
The load exerted by Harmonics on the power network nowadays is increased dramatically. The Harmonic currents are caused by non linear loads. A non linear load is a consumer of electricity that draws a non sinusoidal current
from the supply network. These Harmonic current flows in addition to the regular sine wave, which generates additional losses in the electrical installations. This can result in the thermal overload. The major impact of the harmonic current results in the non sinusoidal voltage wave form that can compromise the Voltage quality. Sensitive loads like medical devices, It infrastructure etc can be affected with such type of Distorted Supply voltage.
Harmonics are dangerous for capacitors connected in the PFC circuit, especially if they operate at a resonant frequency.
The series connection of a reactor and capacitor to detune the series resonant frequency (the capacitors resonant requency) helps to prevent capacitor damage. The most critical frequencies are the 5th and 7th harmonics (250 and 350 Hz at 50 Hz grid frequency). Detuned capacitor banks also help to reduce the harmonic distortion level and clean the network.
Standards | EN 61558-2-20:2000, VDE 0570-2, IEC 60076-6:2007, UL508, C22.2 No.14 |
rated voltages | 230…12000V |
rated frequencies | 50/60 Hz |
Reactor Range | 5-125 kvar |
tolerance of inductance | |
(mean value across three phases) | ±3% |
linearity | = 1.55…2.2 IN |
Detuning Factor | 5.67%(210Hz),7%(189Hz),14%(134Hz) |
harmonic load (continuous operation) | U3 =0.5% UN |
(permanent) | U5 = 6.0% UN |
U7 = 5.0% UN | |
U11 = 3.5% UN | |
U13 = 3.0% UN | |
insulation (winding-to-core) Isolation | 3 kV |
temperature class | T40 |
insulation class | B |
protection class | IP00 indoor mounting |
humidity | 95% |
cooling | natural cooling |
altitude | 4000m |
winding material | Copper /Aluminium |
impregnation | Polyester resin,class F |
terminals | Terminal blocks, cable lugs, or temperature-proof fl exible cables |
This high-speed real-time Automatic Power Factor Correction Panel comes with suitable Tune and Detune harmonics filter. Venus technocrafts ensures that they compensate the reactive power required by any load requiring PF correction in a very short time (less than 20 ms), thereby reducing failure in sophisticated equipment. Maintaining unity PF, reduction in KVA demand, reduced electricity bills, enhanced capacity of transformer, switchgear, HT cable are few of the benefits accrued.
This state-of-the-art electronic switching device is primarily designed as a replacement of the electro-mechanically switched equipment. These systems while distinctly superior come with a price tag very comparable with the conventional switching APFC systems.
HV APFC PANELS
We are also dealing with hv apfc Panel .Purpose of this panel is to provide effective control on a capacitor banks in substation to maintain unity power factor. Therefore this will help us to reduce a maximum demand of Plant.
And also reduces a line losses and transformer losses.
Features :
Application:-
voltage distortion
We are the leading manufacturer of APFC (Automatic Power Factor Correction ) Panels. Located in Pune. APFC or Automatic Power Factor Control Panels are mainly used for the improvement of Power Factor. Power Factor can be explained as ratio of active power to apparent power and it is a key factor in measuring electrical consumption. A dip in Power Factor can attract operational losses and a penalty from electricity board, also if the Power factor is maintained to Unity then the consumer can attract for incentive upto 7% in electricity bill. APFC Panels automatically manage quickly changing loads along with the retention of high Power Factor.
The main features of our control panels are:
For MKP (Heavy duty series)