We offer the best product range of Compressed Air Receiver.

Compressed Air Receiver

Our company offers refrigerated type Compressed Air Receiver 20 - 1500 CFM. It comes with the following components :

  • Microprocessor controller
  • Anti-freezer
  • Anti-recycle controller
  • Advanced 3 in 1 integral heat exchanger
  • Large condenser for high ambient temperatures

Our refrigerated type Compressed Air Receiver uses pre-cooling methodology so that a smaller refrigeration unit can do the job (more economical). The heat exchanger used in this product has no extended surfaces or sharp corners that collect dust, dirt or oil residue, this is by design to ensure that all and any dust, dirt and oil is washed from the air.Our company is based out of Delhi, we supply a wide range of products which include: industrial blowers, compressors, vacuum pumps etc.

Technical Specifications

Model Capacity
(SCFM)
Inlet Press
Kg/cm²
Max Working
Press Kg/cm²
Inlet Temp
deg C
Volt.
Supply
Power
Cons (kW)
Ref
Gas
Noise Level
(dBA)
Weight
(Kg)
End
Conn
GD20 20 7 16 45 230/50/1 0.32 R134a 69 38 3/4" BSP F
GD40 40 7 16 45 230/50/1 0.34 R134a 69 55 1" BSP F
GD50 50 7 16 45 230/50/1 0.34 R134a 69 55 1" BSP F
GD60 60 7 16 45 230/50/1 0.34 R134a 69 55 1" BSP F
GD80 80 7 16 45 230/50/1 0.85 R134a 69 70 1" BSP F
GD100 100 7 16 45 230/50/1 0.85 R134a 69 70 1" BSP F
GD150 150 7 16 45 230/50/1 1.02 R134a 69 110 1.5" BSP F
GD200 200 7 16 45 230/50/1 1.75 R407C 69 100 2" NB
GD250 250 7 16 45 230/50/1 1.75 R407C 69 100 1.5" BSP F
GD300 300 7 16 45 230/50/1 2.3 R407C 69 200 2" NB
GD400 400 7 16 45 415/50/3 2.3 R407C 69 260 2" NB
GD500 500 7 16 45 415/50/3 2.3 R407C 69 290 2" NB
GD650 650 7 16 45 415/50/3 3.34 R407C 69 350 2" NB
GD800 800 7 16 45 415/50/3 4.8 R407C 69 540 3" NB
GD1000 1000 7 16 45 415/50/3 4.8 R407C 69 580 3" NB
GD1250 1250 7 16 45 415/50/3 5.63 R407C 69 620 4" NB
GD1500 1500 7 12 45 415/50/3 7.15 R407C 69 900 4" NB

 

 

 

 











Dryer Sizing - Illustration

Requirement : Inlet flow 100 cfm
Working pressure 5 Kg / cm²
Inlet temperature 45° C
Ambient temperature 38° C
Referring tables : Factor Pi 0.84
Factor Ti 1
Factor Ta 1
Dryer capacity
required :
Flow
Pi x Ti x Ta
100
0.84 x 1 x 1
  119 cfm

 




Correction Factor

Inlet Air Temperature °C 30 38 45 50
Correction Factor (Ti) 1.14 1.08 1 0.75
Inlet Pressure Kg/cm² 2 5 9 12
Factor (Pi) 0.84 1 1.11 1.21
Ambient Temperature °C 25 30 38 43
Factor (Ta) 1.36 1.18 1 0.86

 