Overview

Accuracy and versatility makes the 6500P Series HF LCR Meters the ideal choice for many different tasks and applications in manufacturing and test. The wide range of frequency specifications means that a model can be selected that best meets application requirements and within budget.

High measurement accuracy

Capacitance, inductance and impedance basic accuracy is an excellent 0.05%. Dissipation factor accuracy is 0.0005 and the quality factor accuracy is 0.05%.

Variable drive and bias levels

AC drive levels up to 1V or 20mA can be selected to evaluate components in realistic operating environments.

The /D1 DC bias option provides 0 to +40V dc bias voltage and 0 to +100mA dc bias current while the /D2 option provides -40V to +40V dc bias voltage.

External control

The GPIB interface is used to control the instrument and read back measured values for applications such as quality control or for archiving purposes.

An Ethernet interface similarly allows the instrument to be controlled and to send out data allowing it to be integrated into many test environments.

Wide range of interfaces

An external monitor or projector may be connected to the instrument. The ability to provide a large screen display is invaluable in production environments or for teaching and training.

Instrument control from both a keyboard and mouse is available. Any keyboard or mouse, with either PS/2 or USB interfaces, can be simply connected to provide an alternative method of instrument control and operation.

Data storage and retrieval

All measurement and setup data can be stored using the Ethernet interface or a USB flash memory (supplied as standard).

Setup data

Up to 20 instrument setups may be stored locally for each mode.

Bin handling

The /B1 option (non-isolated 5V) or /B2 option (isolated 24V) signals are available through a 25-way D-type connector. 10 bins can be set using absolute or percentage limits.

Printer outputs

Hard copy printouts can be obtained in a number of ways including direct to an HP-PCL compatible graphics printer or Epson compatible text/ticket printer. A networked HP-PCL compatible printer may also be used via Ethernet connection.

Component connections

Four front panel BNC connectors permit three or four terminal connections with the screens at ground potential.

The 1J1011 component fixture, supplied as standard, ensures optimum performance when measuring a wide range of components of leaded components and devices.

1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.

Protection against charged capacitors

High precision measuring instruments can be damaged by charged capacitors which can cause costly repairs and unacceptable downtime. All the models in the range incorporate protection against charged capacitors.

Comprehensive and precise component tests at higher frequencies

The 6500P series capabilities are best summarised by Comprehensive and precise component tests at higher frequencies. The instruments are the perfect solution for those who have demanding component measurement needs.

  • Key Features
    • Precise high frequency impedance measurements
    • Characterize components from 20 to 120 MHz
    • Wide range of models with maximum frequencies from 5MHz (6505P) to 120MHz (65120P)
    • 0.05% basic measurement accuracy
    • Comprehensive measurement functions
    • 0 to +40V DC bias voltage and 0 to 100mA DC bias Current (Option)
    • 40V DC bias voltage (Option)
    • Easy to use with large TFT touch screen
    • Clear graphic displays aids measurements
    • Resonance Search
    • Intuitive user interface
    • Fully programmable over GPIB
    • Keyboard and mouse optional control
    • Competitively priced

Technical Specification
Measurement Function Capacitance (C)
Inductance (L)
Resistance (R)
Reactance (X)
Conductance (G)
Susceptance (B)
Dissipation Factor (D)
Quality Factor (Q)
Impedance (Z)
Admittance (Y)
Phase Angle (Ø)
Frequency Range 6505P 20Hz to 5MHz
6510P 20Hz to 10MHz
6515P 20Hz to 15MHz
6520P 20Hz to 20MHz
6530P 20Hz to 30MHz
6550P 20Hz to 50MHz
65120P 20Hz to 120MHzFrequency step size <1 mHz
Accuracy of set frequency ±0.005″%
AC Drive Level 10 mV or 1V rms (varies with frequency)
200 µA to 20 mA rms (varies with frequency)
Measurement Speeds 4 speeds selectable
Up to 20 measurements per second for test frequencies ≧100 Hz
Accuracy Dissipation factor – ±0.0005 (1+D2)
Quality factor – ±0.05 %( Q+1/Q)
Capacitance / Inductance / Impedance – ±0.05%
Accuracy varies with frequency, drive level and measured impedance
DC Bias Current (Option) /D1 0 to +100mA dc bias current and 0 to +40V dc bias voltage
/D2 -40V to +40V dc bias voltage
Binning (Option) 10 bins with absolute and percentage limits
25 way d-type interface connector
/B1 (Non-isolated) Comon 0V Bin outputs 0 to 5V(normal) with >10mA current sink capability
/B2 (isolated) Comon 24V input outputs 0 to 24V with >10mA current source capability
Input Specification Power supply – Input voltage 90 V AC to 264 V AC (Autoranging)
Mains frequency 47 to 63 Hz
Display 8.4″ VGA (650 x 480) color TFT with touch panel
Measurement Connections Four front panel BNC connectors permit two, three or four terminal connections with the screens at ground potential.
1J1011 Component Fixture (supplied as standard) allows connection to leaded components and devices.
1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.
Printer HP-PCL compatible graphics printing (local and network)
Centronics / parallel printer port, Epson compatible text/ticket printing (local)
Remote Trigger Rear panel BNC with internal pull-up, operates on logic low or contact closure
GPIB Interface External instrument control 24 pin IEEE 488 connector
USB Interface Two Unversal Serial Bus (USB) interfaces
USB 1.1 compliant
VGA Interface 15-way D-type connector to drive an external monitor in addition to the internal screen
Network Interface 10/100-BASETX Ethernet controller
RJ45 connector
Keyboard Interface Standard USB or PS/2 keyboard port. Instrument front panel remains active with keyboard plugged in
Mouse Interface Standard USB or PS/2 mouse port
Touch screen remains enabled when the mouse is connected

































View Complete Details

Lcr Meters

2.50 Lakh - 5 Lakh / one Get Latest Price
  • Number Of Flower Lcr Meter
  • Application Indsustrial Usage
  • Feature Accuracy, Durable, Light Weight, Stable Performance
  • Display Type Digital
  • Frequency 50Hz-65Hz
  • Automatic Grade Automatic, Manual
  • Power Source Electric
  • Total Carbohydrate 1Year
  • Brand Name Wayne Kerr Electronics
  • Operating Temperature 0-45Deg

Overview A range of easy to use LCR meters with comprehensive measurement functions.

Accurate and fast measurements may be made from 20Hz to 1MHz (43100) making the 4300 series the ideal choice for many applications in the test or production environments.

Two test mode enables consecutive measurements to be made with two different instrument parameters set. For example two AC measurements may be made at different frequencies or an AC and a Rdc measurement may be made.

Measurement limits may be set in Scale or Operator modes.

An optional component Binning module may be specified which provides an interface to component sorting machines. Limits set in the instrument Binning mode enable a wide range of components to be sorted while the choice of isolated or non-isolated modules give interface flexibility.

The optional Scaleizer handler module provides PASS/FAIL and data synchronisation relay outputs for limit checked measurements. Two output signal configurations are available.

Up to 20 measurements set ups can be saved with user defined names for later recall.

All 4300 series instruments may be externally controlled using the standard RS232, GPIB, USB or LAN interfaces.

  • Key Features
    • Test components from 20Hz to 1 MHz (43100)
    • 0.1% basic accuracy
    • < 25ms measurement time
    • Parameters C, L, Z, Y, X, B, Rac, Rdc, G, Q, D,
    • Single or two test operation
    • Up to four parameters may be displayed (two test mode)
    • Drive level from 10mV to 2Vrms
    • Scale mode with measurement target limits
    • Operator mode with target limits
    • +2V internal or up to 40Vdc external bias
    • Measurement setup Save and Recall
    • GPIB / IEEE-488, USB, LAN and RS-232 interfaces
    • Handler Scaleizer module (Optional)
    • Binning (Optional)
    • Protection against charged capacitors
    • Small size and light weight

Technical Specification
  4310 4320 4350 43100
Frequency Range 20 Hz to 100 kHz 20 Hz to 200 kHz 20 Hz to 500 kHz 20 Hz to 1 MHz
Frequency Steps 5 Hz     – 20 Hz to 1 kHz
50 Hz   – 1 kHz to 10 kHz
500 Hz – 10 kHz to 100 kHz
5 kHz   – 100 kHz to 1 MHz
Measurement Function Any of the following parameters can be measured and displayed:
Impedance (Z)             Phase Angle (Ө)
Capacitance (C)           Dissipation Factor (D)
Inductance (L)             Quality Factor (Q)
AC Resistance (Rac)   Reactance (X)
Susceptance (B)          Conductance (G)
Admittance (Y)DC Resistance (Rdc) is an option (/R) on all models.
Measurement Function –
DC Resistance (Rdc)
option (/R)
Series/parallel equivalent circuit Any combination
Polar Form Z + Ө, Y + Ө
Drive Level
(AC measurements)
Open circuit:                     10 mV to 2V rms
Voltage step size:              10 mV (200 steps)
Short circuit:                      100 µA to 20 mA rms
Current step size:              100 µA (200 steps)
Signal source impedance:   100Ω
DC Bias Voltage Internal – 2 Vdc
External – up to ±40V may be connected via rear panel
Measurement Speeds Four selectable speeds for all measurement functions
Up to 50 measurements per second depending on test frequency and setup condition
Measurement Ranges Z, R, X          0.01 mΩ to > 1 GΩ
Y, B, G          0.1 nS to > 2 kS
L                    1 nH to > 2 kH
C                    0.01 pF to > 1 F
D, Q               0.0001 to 9999.9
Phase Angle -180° to +180°
Rdc                0.1 mΩ to > 100 MΩ
Basic Accuracy 0.1% varies with speed, frequency, AC drive level and impedance of device under test
Binning (Optional) User programmable PASS and FAIL bins. 25 way D-type interface connector.
Option /B1 (non-isolated) – Common 0V. Bin outputs 0 to 5V (nominal) with >10 mA current sink capability.
Option /B2 (isolated) – Common 24V input. Outputs 0 to 24V with >10 mA current source capability.

























View Complete Details