Cable Characteristics (for Example FXMMS 8 SMT)
| Maximum pulling force | 1500 N EN 187000 method 501 |
|---|---|
| Crush strength / 100 mm (plate) | 4000 N EN 187000 method 504 |
| Crush strength / 25 mm (mandrel) | 750 N EN 187000 method 504 |
| Impact strength, R = 300 mm | 30 J EN 187000 method 505 |
| Sheath marking | Cable type, manufacturer, man. no., man. time, length marking in m. |
| Minimum bending radius | 195 mm during installation, 130 mm in final bending |
| Nominal cable diameter | 13.1 mm |
| Cable weight | 142 kg/km |
| Minimum installation temperature | -15 oC |
| Operating temperature range | -45...+70 °C |
| Flame-retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-24 -test for bunched wires and cables, category C |
| Halogen-free | IEC 60754 series |
| Smoke emission | IEC 61034 series |

Cable Characteristics (for Example FXMSU 2x6 SML + 3x4 GKL)
| Maximum pulling force | 500 N EN 187000 method 501 |
|---|---|
| Crush strength / 100 mm (plate) | 4000 N EN 187000 method 5 |
| Crush strength / 25 mm (mandrel) | 650 N EN 187000 method 504 |
| Impact strength | 30 J EN 187000 method 505 |
| Sheath marking | Cable type, manufacturer, man. no., man. time, length marking in m. |
| Minimum bending radius | 140 mm during installation, 100 mm in final bending |
| Nominal cable diameter | 9.4 mm |
| Cable weight | 75 kg/km |
| Minimum installation temperature | -15 oC |
| Operating temperature range | -45 +70 oC |
| Longitudinal water tightness | EN 187000 method 605B |
| Flame-retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Halogen-free | IEC 60754 series |
| Smoke emission | IEC 61034 series |