Main Characteristics
| Rated Voltage | 150/250V (300V) |
|---|---|
| Maximum Conductor Temperature | + 90oC |
| Flame Retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Fire Resistant | IEC 60331-21 |
| Halogen Free | IEC 60754 series |
| Smoke Emission | IEC 61034 series |
Electrical Data
| Parameters | 0,75mm2 | Unit |
|---|---|---|
| Loop resistance of pair, max. / +20oC | 52 | ohm/km |
| Pair capacitance, nom. / 800Hz | 55 | nF/km |
| Loop inductance, nom. | 0,6 | mH/km |
| Insulation resistance / +20oC | ≥1500 | Mohm*km. |
Specifications
| RFA-FRHF(i) 250V | Number of conductors & cross-section n x mm2 | Nominal outer diameter mm | Approximate weight kg/km | Min. bending radius fixed installation mm |
| Part number | ||||
| 20 667 | 2x2x0,75 | 13,5 | 155 | 85 |
| 20 669 | 4x2x0,75 | 15,5 | 245 | 95 |
| 20 671 | 7x2x0,75 | 18,5 | 380 | 115 |
| 20 673 | 8x2x0,75 | 20,0 | 430 | 120 |
| 20 675 | 10x2x0,75 | 23,5 | 545 | 145 |
| 20 677 | 12x2x0,75 | 24,5 | 625 | 150 |
| 20 679 | 14x2x0,75 | 26,0 | 725 | 160 |
| 20 683 | 19x2x0,75 | 30,0 | 945 | 180 |
| 20 685 | 24x2x0,75 | 34,0 | 1205 | 205 |
Main Characteristics
| Rated Voltage | 150/250V (300V) |
|---|---|
| Maximum Conductor Temperature | + 90oC |
| Flame Retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Fire Resistant | IEC 60331-21 |
| Halogen Free | IEC 60754 series |
| Smoke Emission | IEC 61034 series |
Electrical Data
| Parameters | 0,75mm2 | 1,5mm2 | Unit |
|---|---|---|---|
| Loop resistance of pair, max. / +20oC | 52 | 24,4 | ohm/km |
| Pair capacitance, nom. / 800Hz | 55 | 75 | nF/km |
| Loop inductance, nom. | 0,6 | 0,7 | mH/km |
| Insulation resistance / +20oC | ≥1500 | ≥1500 | Mohm*km. |
Specifications
| RFE-FRHF(i) 250V | Number of conductors & cross-section n x mm2 | Nominal outer diameter mm | Approximate weight kg/km | Min. bending radius fixed installation mm |
| Part number | ||||
| 20 546 | 1x2x0,75 | 9,5 | 125 | 60 |
| 20 550 | 2x2x0,75 | 14,5 | 225 | 90 |
| 20 552 | 4x2x0,75 | 17,0 | 355 | 105 |
| 20 554 | 7x2x0,75 | 20,0 | 515 | 125 |
| 20 556 | 8x2x0,75 | 22,0 | 585 | 135 |
| 20 558 | 10x2x0,75 | 25,0 | 710 | 150 |
| 20 560 | 12x2x0,75 | 26,0 | 800 | 155 |
| 20 562 | 14x2x0,75 | 27,5 | 910 | 170 |
| 20 564 | 19x2x0,75 | 32,0 | 1175 | 195 |
| 20 566 | 24x2x0,75 | 35,0 | 1425 | 215 |
| 20 603 | 1x2x1,5 | 10,5 | 165 | 65 |
| 20 605 | 2x2x1,5 | 16,5 | 320 | 100 |
| 20 607 | 4x2x1,5 | 19,0 | 475 | 115 |
| 20 609 | 7x2x1,5 | 23,0 | 720 | 140 |
| 20 611 | 8x2x1,5 | 24,5 | 810 | 150 |
| 20 613 | 10x2x1,5 | 28,0 | 985 | 170 |
| 20 615 | 12x2x1,5 | 29,5 | 1145 | 180 |
| 20 617 | 14x2x1,5 | 31,5 | 1295 | 190 |

Main Characteristics
| Rated Voltage | 150/250V (300V) |
|---|---|
| Maximum Conductor Temperature | + 90oC |
| Flame Retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Fire Resistant | IEC 60331-21 |
| Halogen Free | IEC 60754 series |
| Smoke Emission | IEC 61034 series |
Electrical Data
| Parameters | 0,75mm2 | 1,5mm2 | Unit |
|---|---|---|---|
| Loop resistance of pair, max. / +20oC | 52 | 24,4 | ohm/km |
| Pair capacitance, nom. / 800Hz | 55 | 75 | nF/km |
| Loop inductance, nom. | 0,6 | 0,7 | mH/km |
| Insulation resistance / +20oC | ≥1500 | ≥1500 | Mohm*km. |
Specifications
| RFE-FRHF(i) 250V | Number of conductors & cross-section n x mm2 | Nominal outer diameter mm | Approximate weight kg/km | Min. bending radius fixed installation mm |
| Part number | ||||
| 20 546 | 1x2x0,75 | 9,5 | 125 | 60 |
| 20 550 | 2x2x0,75 | 14,5 | 225 | 90 |
| 20 552 | 4x2x0,75 | 17,0 | 355 | 105 |
| 20 554 | 7x2x0,75 | 20,0 | 515 | 125 |
| 20 556 | 8x2x0,75 | 22,0 | 585 | 135 |
| 20 558 | 10x2x0,75 | 25,0 | 710 | 150 |
| 20 560 | 12x2x0,75 | 26,0 | 800 | 155 |
| 20 562 | 14x2x0,75 | 27,5 | 910 | 170 |
| 20 564 | 19x2x0,75 | 32,0 | 1175 | 195 |
| 20 566 | 24x2x0,75 | 35,0 | 1425 | 215 |
| 20 603 | 1x2x1,5 | 10,5 | 165 | 65 |
| 20 605 | 2x2x1,5 | 16,5 | 320 | 100 |
| 20 607 | 4x2x1,5 | 19,0 | 475 | 115 |
| 20 609 | 7x2x1,5 | 23,0 | 720 | 140 |
| 20 611 | 8x2x1,5 | 24,5 | 810 | 150 |
| 20 613 | 10x2x1,5 | 28,0 | 985 | 170 |
| 20 615 | 12x2x1,5 | 29,5 | 1145 | 180 |
| 20 617 | 14x2x1,5 | 31,5 | 1295 | 190 |

Main Characteristics
| Rated Voltage | 150/250V (300V) |
|---|---|
| Maximum Conductor Temperature | + 90oC |
| Flame Retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Fire Resistant | IEC 60331-21 |
| Halogen Free | IEC 60754 series |
| Smoke Emission | IEC 61034 series |
Electrical Data
| Parameters | 0,75mm2 | 1,5mm2 | Unit |
|---|---|---|---|
| Loop resistance of pair, max. / +20oC | 52 | 24,4 | ohm/km |
| Pair capacitance, nom. / 800Hz | 45 | 55 | nF/km |
| Loop inductance, nom. | 0,6 | 0,7 | mH/km |
| Insulation resistance / +20oC | ≥1500 | ≥1500 | Mohm*km. |
Specifications
| RFE-FRHF 250V | Number of conductors & cross-section n x mm2 | Nominal outer diameter mm | Approximate weight kg/km | Min. bending radius fixed installation mm |
| Part number | ||||
| 20 520 | 1x2x0,75 | 9,5 | 115 | 60 |
| 20 522 | 2x2x0,75 Quad | 11,0 | 160 | 70 |
| 20 524 | 2x2x0,75 | 14,0 | 210 | 85 |
| 20 526 | 4x2x0,75 | 16,5 | 325 | 100 |
| 20 528 | 7x2x0,75 | 20,0 | 465 | 120 |
| 20 530 | 8x2x0,75 | 21,0 | 510 | 130 |
| 20 532 | 10x2x0,75 | 24,5 | 630 | 150 |
| 20 534 | 12x2x0,75 | 25,5 | 705 | 155 |
| 20 536 | 14x2x0,75 | 27,0 | 800 | 165 |
| 20 538 | 19x2x0,75 | 31,0 | 1015 | 190 |
| 20 540 | 24x2x0,75 | 34,5 | 1245 | 210 |
| 20 575 | 1x2x1,5 | 10,5 | 155 | 65 |
| 20 577 | 2x2x1,5 Quad | 12,0 | 220 | 75 |
| 20 579 | 2x2x1,5 | 16,0 | 315 | 100 |
| 20 581 | 4x2x1,5 | 18,5 | 430 | 115 |
| 20 583 | 7x2x1,5 | 22,5 | 650 | 140 |
| 20 585 | 8x2x1,5 | 24,0 | 715 | 150 |
| 20 587 | 10x2x1,5 | 27,5 | 875 | 165 |
| 20 589 | 12x2x1,5 | 29,0 | 1000 | 175 |
| 20 591 | 14x2x1,5 | 30,5 | 1125 | 185 |

Main Characteristics
| Rated Voltage | 150/250V (300V) |
|---|---|
| Maximum Conductor Temperature | + 90oC |
| Flame Retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Halogen Free | IEC 60754 series |
| Smoke Emission | IEC 61034 series |
Electrical Data
| Parameters | 0,5mm2 | 0,75mm2 | 1,5mm2 | Unit |
|---|---|---|---|---|
| Loop resistance of pair, max. / +20oC | 80 | 52 | 24,4 | ohm/km |
| Pair capacitance, nom. / 800Hz | 55 | 50 | 60 | nF/km |
| Loop inductance, nom. | 0,6 | 0,6 | 0,7 | mH/km |
| Insulation resistance / +20oC | ≥1500 | ≥1500 | ≥1500 | Mohm*km. |
Specifications
| RFE-FRHF(i) 250V | Number of conductors & cross-section n x mm2 | Nominal outer diameter mm | Approximate weight kg/km | Min. bending radius fixed installation mm |
| Part number | ||||
| 20 362 | 1x2x0,5 | 7,5 | 85 | 45 |
| 20 364 | 2x2x0,5 Quad | 8,0 | 100 | 50 |
| 20 363 | 2x2x0,5 | 10,5 | 130 | 65 |
| 20 366 | 4x2x0,5 | 11,5 | 170 | 70 |
| 20 368 | 7x2x0,5 | 14,0 | 245 | 85 |
| 20 369 | 8x2x0,5 | 14,5 | 270 | 90 |
| 20 370 | 10x2x0,5 | 17,0 | 350 | 105 |
| 20 371 | 12x2x0,5 | 17,5 | 390 | 105 |
| 20 372 | 14x2x0,5 | 18,5 | 440 | 115 |
| 20 374 | 19x2x0,5 | 21,0 | 545 | 130 |
| 20 376 | 24x2x0,5 | 23,5 | 665 | 145 |
| 20 378 | 37x2x0,5 | 28,0 | 930 | 170 |
| 20 382 | 1x2x0,75 | 7,5 | 95 | 45 |
| 20 384 | 2x2x0,75 Quad | 9,0 | 125 | 55 |
| 20 383 | 2x2x0,75 | 11,0 | 155 | 70 |
| 20 386 | 4x2x0,75 | 12,5 | 215 | 75 |
| 20 388 | 7x2x0,75 | 15,5 | 330 | 95 |
| 20 389 | 8x2x0,75 | 16,0 | 375 | 100 |
| 20 390 | 10x2x0,75 | 18,5 | 440 | 115 |
| 20 391 | 12x2x0,75 | 19,0 | 490 | 115 |
| 20 392 | 14x2x0,75 | 20,5 | 565 | 125 |
| 20 394 | 19x2x0,75 | 23,5 | 715 | 145 |
| 20 396 | 24x2x0,75 | 26,0 | 860 | 160 |
| 20 490 | 1x2x1,5 | 10,0 | 140 | 60 |
| 20 491 | 2x2x1,5 Quad | 11,0 | 190 | 70 |
| 20 492 | 2x2x1,5 | 14,5 | 235 | 90 |
| 20 493 | 4x2x1,5 | 17,0 | 375 | 105 |
| 20 494 | 7x2x1,5 | 20,0 | 545 | 120 |
| 20 495 | 8x2x1,5 | 21,5 | 625 | 130 |
| 20 496 | 10x2x1,5 | 24,5 | 760 | 150 |
| 20 497 | 12x2x1,5 | 25,5 | 855 | 155 |
| 20 498 | 14x2x1,5 | 27,0 | 960 | 165 |
| 20 499 | 19x2x1,5 | 31,0 | 1230 | 190 |

Main Characteristics
| Rated Voltage | 150/250V (300V) |
|---|---|
| Maximum Conductor Temperature | + 90oC |
| Flame Retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Fire Resistant | IEC 60331-21 |
| Halogen Free | IEC 60754 series |
| Smoke Emission | IEC 61034 series |
Electrical Data
| Parameters | 0,75mm2 | Unit |
|---|---|---|
| Loop resistance of pair, max. / +20oC | 52 | ohm/km |
| Pair capacitance, nom. / 800Hz | 45 | nF/km |
| Loop inductance, nom. | 0,6 | mH/km |
| Insulation resistance / +20oC | ≥1500 | Mohm*km. |
Specifications
| RFA-FRHF 250V | Number of conductors & cross-section n x mm2 | Nominal outer diameter mm | Approximate weight kg/km | Min. bending radius fixed installation mm |
| Part number | ||||
| 20 635 | 1x2x0,75 | 8,5 | 75 | 55 |
| 20 637 | 2x2x0,75 Quad | 10,0 | 120 | 60 |
| 20 639 | 2x2x0,75 | 13,0 | 135 | 80 |
| 20 641 | 4x2x0,75 | 15,5 | 215 | 95 |
| 20 643 | 7x2x0,75 | 18,5 | 330 | 115 |
| 20 645 | 8x2x0,75 | 20,0 | 380 | 120 |
| 20 647 | 10x2x0,75 | 23,0 | 480 | 140 |
| 20 649 | 12x2x0,75 | 24,0 | 545 | 145 |
| 20 651 | 14x2x0,75 | 25,5 | 620 | 155 |
| 20 655 | 19x2x0,75 | 29,5 | 805 | 180 |
| 20 657 | 24x2x0,75 | 33,5 | 1030 | 205 |

Main Characteristics
| Rated Voltage | 150/250V (300V) |
|---|---|
| Maximum Conductor Temperature | + 90oC |
| Flame Retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Fire Resistant | IEC 60331-21 series |
| Halogen Free | IEC 60754 series |
| Smoke Emission | IEC 61034 series |
Specifications
| LKAM-FRHF 250V | Number of conductors & cross-section n x mm2 | Nominal outer diameter mm | Approximate weight kg/km | Current rating A | Min. bending radius fixed installation mm |
| Part number | |||||
| 22466 | 2x0,75 | 8,5 | 70 | 11,3 | 50 |
| 22467 | 3x0,75 | 9,0 | 85 | 9,8 | 55 |
| 22468 | 4x0,75 | 10,0 | 115 | 8,9 | 60 |
| 22469 | 5x0,75 | 11,0 | 135 | 8,3 | 65 |
| 22470 | 7x0,75 | 11,5 | 165 | 7,4 | 70 |
| 22471 | 10x0,75 | 15,0 | 230 | 6,6 | 90 |
| 22472 | 12x0,75 | 15,5 | 260 | 6,2 | 95 |
| 22473 | 14x0,75 | 16,5 | 300 | 5,9 | 100 |
| 22474 | 16x0,75 | 17,5 | 340 | 5,6 | 105 |
| 22475 | 19x0,75 | 18,0 | 380 | 5,3 | 110 |
| 22477 | 24x0,75 | 21,5 | 480 | 4,9 | 130 |
| 22478 | 27x0,75 | 22,0 | 525 | 4,7 | 130 |
| 22479 | 32x0,75 | 23,0 | 620 | 4,5 | 140 |
| 22480 | 37x0,75 | 25,0 | 700 | 4,3 | 150 |

Main Characteristics
| Rated voltage | 150/250V (300V) |
|---|---|
| Maximum Conductor Temperature | + 90oC |
| Flame Retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Fire Resistant | IEC 60331-21 series |
| Halogen Free | IEC 60754 series |
| Smoke Emission | IEC 61034 series |
Specifications
| LKAM-HF 250V | Number of conductors & cross-section n x mm2 | Nominal outer diameter mm | Approximate weight kg/km | Current rating A | Min. bending radius fixed installation mm |
| Part number | |||||
| 22406 | 2x0,75 | 8,5 | 65 | 11,3 | 35 |
| 22407 | 3x0,75 | 9,0 | 80 | 9,8 | 35 |
| 22408 | 4x0,75 | 10,0 | 110 | 8,9 | 40 |
| 22409 | 5x0,75 | 11,0 | 130 | 8,3 | 45 |
| 22410 | 7x0,75 | 11,5 | 160 | 7,4 | 45 |
| 22411 | 10x0,75 | 15,0 | 225 | 6,6 | 60 |
| 22412 | 12x0,75 | 15,5 | 255 | 6,2 | 60 |
| 22413 | 14x0,75 | 16,5 | 295 | 5,9 | 65 |
| 22414 | 16x0,75 | 17,5 | 330 | 5,6 | 70 |
| 22415 | 19x0,75 | 18,0 | 375 | 5,3 | 75 |
| 22417 | 24x0,75 | 21,5 | 475 | 4,9 | 85 |
| 22418 | 27x0,75 | 22,0 | 520 | 4,7 | 85 |
| 22419 | 32x0,75 | 23,0 | 615 | 4,5 | 90 |
| 22420 | 37x0,75 | 25,0 | 695 | 4,3 | 100 |

Main Characteristics
| Rated voltage | 150/250V (300V) |
|---|---|
| Maximum conductor temperature | + 90 oC |
| Flame-retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Fire-resistant | IEC 60331-21 series |
| Halogen-free | IEC 60754 series |
| Smoke emission | IEC 61034 series |
Specification
| LKSM-FRHF 0,6/1kV | Number ofconductors & cross-section n x mm2 | Crosssection of screen Mm2 | Nominal outer diameter Mm | Approximate weight kg/km | Current rating A | Min. bending radius fixed installation Mm |
| Part number | ||||||
| 22436 | 2x0,75 | 3,6 | 9,0 | 105 | 11,3 | 55 |
| 22437 | 3x0,75 | 3,9 | 10,0 | 135 | 9,8 | 60 |
| 22438 | 4x0,75 | 4,4 | 11,0 | 160 | 8,9 | 65 |
| 22439 | 5x0,75 | 4,9 | 11,5 | 185 | 8,3 | 70 |
| 22440 | 7x0,75 | 5,4 | 12,5 | 220 | 7,4 | 75 |
| 22441 | 10x0,75 | 11,6 | 16,0 | 350 | 6,6 | 95 |
| 22442 | 12x0,75 | 11,6 | 16,5 | 380 | 6,2 | 100 |
| 22443 | 14x0,75 | 11,7 | 17,5 | 415 | 5,9 | 105 |
| 22444 | 16x0,75 | 11,3 | 18,5 | 445 | 5,6 | 110 |
| 22445 | 19x0,75 | 11,9 | 19,5 | 505 | 5,3 | 115 |
| 22447 | 24x0,75 | 14,3 | 23,0 | 640 | 4,9 | 135 |
| 22448 | 27x0,75 | 14,6 | 23,5 | 685 | 4,7 | 140 |
| 22449 | 32x0,75 | 15,3 | 24,0 | 765 | 4,5 | 145 |
| 22450 | 37x0,75 | 16,7 | 26,0 | 870 | 4,3 | 155 |

Main Characteristics
| Rated voltage | 150/250V (300V) |
|---|---|
| Maximum conductor temperature | + 90 oC |
| Flame-retardant | IEC 60332-1-2 -test for single insulated wire and cable IEC 60332-3-22 -test for bunched wires and cables, category A |
| Halogen-free | IEC 60754 series |
| Smoke emission | IEC 61034 series |
Specification
| LKSM-FRHF 0,6/1kV | Number of conductors & cross-section n x mm2 | Crosssection of screen mm2 | Nominal outer diameter Mm | Approximate weight kg/km | Current rating A | Min. bending radius fixed installation Mm |
| Part number | ||||||
| 26402 | 2x0,75 | 3,6 | 7,5 | 90 | 11,3 | 45 |
| 26403 | 3x0,75 | 3,6 | 8,0 | 100 | 9,8 | 50 |
| 26404 | 4x0,75 | 3,6 | 8,5 | 110 | 8,9 | 50 |
| 26405 | 5x0,75 | 4,1 | 9,5 | 140 | 8,3 | 55 |
| 26407 | 7x0,75 | 4,1 | 10,0 | 160 | 7,4 | 60 |
| 26410 | 10x0,75 | 5,1 | 12,5 | 220 | 6,6 | 70 |
| 26412 | 12x0,75 | 5,3 | 13,0 | 240 | 6,2 | 75 |
| 26414 | 14x0,75 | 5,6 | 13,5 | 265 | 5,9 | 75 |
| 26416 | 16x0,75 | 6,1 | 14,0 | 295 | 5,6 | 80 |
| 26419 | 19x0,75 | 8,7 | 14,5 | 330 | 5,3 | 85 |
| 26424 | 24x0,75 | 11,7 | 17,5 | 450 | 4,9 | 100 |
| 26427 | 27x0,75 | 11,7 | 17,5 | 480 | 4,7 | 100 |
| 26432 | 32x0,75 | 11,8 | 18,5 | 540 | 4,5 | 105 |
| 26437 | 37x0,75 | 11,9 | 19,5 | 600 | 4,3 | 115 |
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : WOODEN DRUMS OR CORRUGATED BOXES
Delivery Time : ONE MONTH IN INDIA/PORT
Additional Information:
Payment Terms : L/C
Packaging Details : WOODEN DRUMS OR CORRUGATED BOXES
Delivery Time : ONE MONTH IN INDIA/PORT
Additional Information:
Payment Terms : L/C, T/T
Packaging Details : WOODEN DRUMS OR CORRUGATED BOXES
Delivery Time : ONE MONTH IN INDIA/PORT