EXPLOSION-PROOF FLUORESCENT LAMP


  • Explosion protection to
    -CENELEC
    -lEC
    -NEC

  • Can be used in
    Zone 1 and Zone 2
    Zone 21 and Zone 22
    Class I, Zone 1 and Zone 2
    Class I, Division 2, Groups A, B, C, D

  • Polycarbonate diffuser, high transmittance, resistance to heavy impact.

  • Main enclosure is extruding formed of copper-free aluminium, anodic-oxidation treatment for surface. Both ends of enclosures are die-casting formed of copper-free aluminium, powder coated surface.

  • Built-in electronic ballast, power factor 0.95.

  • Special-made mounting bracket, the illumination angle can be adjusted on request.

  • Emergency function is available on request.

  • End of lamp life (EOL) rectification effect protection

View Complete Details

Incandescent Hand Lamps


  • Explosion protection to
    -CENELEC
    -IEC
    -NEC

  • Can be used in
    Zone 1 and Zone 2
    Class I, Zone 1 and Zone 2
    Class l, Division 2, Groups A, B, C, D

  • Incandescent lamp: Max. 60W

  • Cable supplied on request

  • Handle in plastic, with control push button

  • Powder coated wire guard, white

  • Toughened glass cover resistant to temperature changes

  • Movable transformer available on request

View Complete Details

Led Street Lamps


  • Explosion protection to
    -CENELEC
    -IEC
    -NEC

  • Can be used in
    Zone 2
    Zone 21 and Zone 22
    Class I, Zone 2
    Class I, Division 2, Groups A, B, C, D

  • Five enclosure types: 60, 90, 120, 150, 180

  • Applicable lamp and power (max.180W)
    LED: 60W, 90W, 120W, 150W, 180W

  • Enclosure: Extrusion formed with good cooling performance.

  • Unique design without an external power supply; power accessories and lamp are integrated.

View Complete Details

Street Lamps

BAT53-250, BAT53-400, BAT85-400 Series
HRD91-250, HRD91-400 Series
BDD91-150, BDD91-250, BDD91-400 Series
BAT86 Series, BnT81 Series, HRT81 Series



  • Explosion protection to
    -CENELEC
    -IEC
    -NEC

  • Can be used in
    Zone 1 and Zone 2
    Zone 21 and Zone 22

  • Please refer to the mounting schematic diagram to select the appropriate lamp and mounting type

  • Please refer to the individual light fitting entry for detailed technical data and ordering information for each light fitting.

  • Note: If BAT53-250 type street lamp is required, please specify when ordering.

  • The street lamps are supplied without poles; please specify when ordering.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Shijina (ASWATHY CORPORATION)
  • 107-110, Ashok Service Industrial Estate, L.B.S. Marg, Bhandup (West), Pin 400 078 MUMBAI, Maharashtra, Bhandup West - 400078
  • Share us via
Retailer of Lamps from MUMBAI, Maharashtra by ASWATHY CORPORATION
Post Buy Requirement
AC
MUMBAI, Maharashtra, India
Add Review

Lamps #207431

EXPLOSION-PROOF FLUORESCENT LAMP

  • Explosion protection to-CENELEC-lEC-NEC
  • Can be used inZone 1 and Zone 2Zone 21 and Zone 22Class I, Zone 1 and Zone 2Class I, Division 2, Groups A, B, C, D
  • Polycarbonate diffuser, high transmittance, resistance to heavy impact.
  • Main enclosure is extruding formed of copper-free aluminium, anodic-oxidation treatment for surface. Both ends of enclosures are die-casting formed of copper-free aluminium, powder coated surface.
  • Built-in electronic ballast, power factor 0.95.
  • Special-made mounting bracket, the illumination angle can be adjusted on request.
  • Emergency function is available on request.
  • End of lamp life (EOL) rectification effect protection
View Complete Details

Incandescent Hand Lamps

  • Explosion protection to-CENELEC-IEC-NEC
  • Can be used inZone 1 and Zone 2Class I, Zone 1 and Zone 2Class l, Division 2, Groups A, B, C, D
  • Incandescent lamp: Max. 60W
  • Cable supplied on request
  • Handle in plastic, with control push button
  • Powder coated wire guard, white
  • Toughened glass cover resistant to temperature changes
  • Movable transformer available on request
View Complete Details

Led Street Lamps

  • Explosion protection to-CENELEC-IEC-NEC
  • Can be used inZone 2Zone 21 and Zone 22Class I, Zone 2Class I, Division 2, Groups A, B, C, D
  • Five enclosure types: 60, 90, 120, 150, 180
  • Applicable lamp and power (max.180W)LED: 60W, 90W, 120W, 150W, 180W
  • Enclosure: Extrusion formed with good cooling performance.
  • Unique design without an external power supply; power accessories and lamp are integrated.
View Complete Details

Street Lamps

BAT53-250, BAT53-400, BAT85-400 SeriesHRD91-250, HRD91-400 SeriesBDD91-150, BDD91-250, BDD91-400 SeriesBAT86 Series, BnT81 Series, HRT81 Series

  • Explosion protection to-CENELEC-IEC-NEC
  • Can be used inZone 1 and Zone 2Zone 21 and Zone 22
  • Please refer to the mounting schematic diagram to select the appropriate lamp and mounting type
  • Please refer to the individual light fitting entry for detailed technical data and ordering information for each light fitting.
  • Note: If BAT53-250 type street lamp is required, please specify when ordering.
  • The street lamps are supplied without poles; please specify when ordering.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Shijina (ASWATHY CORPORATION)
  • 107-110, Ashok Service Industrial Estate, L.B.S. Marg, Bhandup (West), Pin 400 078 MUMBAI, Maharashtra, Bhandup West - 400078
  • Share us via