We are offering numerical directional over current relay. Features programmable characteristic angle programmable operating characteristics high speed directional control low burden trip test facility....
We are offering numerical over current relay. Features programmable for 1a 5a relay rating programmable system rated frequency (5060hz) 3 oc + 1 ef + 1 sefref available in both low load and normal load configurations choice of 6 idmt curves and...
The IDMT/DEFINITE TIME/INSTANTANEOUS LOW-SET/HIGH-SET NON-DIRECTIONAL NUMERICAL/MICROPROCESSOR BASED OVER CURRENT RELAY (OCR) WITH EARTH FAULT RELAY (EFR) of KP Series PNA TYPE is extensively used for selective short circuit and earth fault...
Relay has modbus protocol with RS 485 port with baud rate 9600bps. Another model is established for special applications with baud rate115kbps.Relay records 99 faults with date and time. Relay rating (In) is field selectable- either 1A/5A.The output...
Prok dv's make PNA TYPE IDMT/DEFINITE TIME/INSTANTANEOUS LOW-SET/HIGH-SET NONDIRECTIONAL NUMERICAL/MICROPROCESSOR BASED OVER CURRENT RELAY (OCR) WITH EARTH FAULT RELAY (EFR) or independent over current Relay (OCR) or earth fault relay (EFR). This is...
Being a client-centric organization, we are engaged in manufacturing, supplying, exporting and trading Numerical Over Current Relay. Based Over Current Relay (OCR) with Earth Fault Relay (EFR), these relays are extensively used for selective over...
The circulating current relay IRXm is mainly used for high-speed restricted earth fault protection of generators and transformer windings. For the selective detection of faults, current transformers in summation connection are employed with an...
We are offering numerical sensitive current protection relay. Mit 161 is a numerical protection unit comprising two elements namely the earth fault element and lowset thereby offering two stages of protection. The earth fault element, the first...
Features Programmable for 1A / 5A relay rating 3 OC + 1 EF + 1 SEF/REF Choice of 6 IDMT curves and definite time Trip test facility History of 6 latest faults along with settings Self supervision facility MODBUS open protocol over RS – 485 port...
Features Software based design Programmable time current characteristics Choice of four curves Selectable characteristic angle Programmable directional / Non-directional element Draw - out case Principle of Operation: The relay measures the line...
Features No Auxiliary supply Programmable operating characteristics Low burden Wide setting range LED fault flag indication Principle of Operation: If a fault occurs at the distribution end and the respective protective relay operates but the...
each pole of the relay is phase segregated and operates independently via its level detector and interface area. The provision of the interface area allows for the factory fitting of output relays to the customer's requirements. With this...
Short Circuit Protection Relay are applied in cases where only protection against short circuit currents is required. It has featues like LED indication of fault condition, Timer-controlled tripping and LED indication for activated relay....
Magnetic latching relay, Ortecs specializes and makes available custom & standard relays for the vivid industries, acknowledged for the advanced technological design, durability and high performance, our Electronic Components are high in demand in...