Our Products
Our offered Product range includes Medical Refrigerator, Blood Bank Refrigerator, Ultra Low Freezer- 80 C &- 86 C, Solar Freezer and Cryogenic Freezer.
Blood bank refrigerators is used to store blood bags under controlled temperature.
Tempereture control range from + 4 degree C, with setting accuracy of +/- 0.1 degree C of temperature controller.
The system have positive, forced, air citculation to maintain temperature uniformity at all shelf levels, with quick recovery +/- degree C.
BBR have density cfc -free polyurethane foam insulation to protect cabinet from ambient temperature
Purpose & Summarze
These products are applicable in blood banks, hospitals, epidemic prevention services and so on.In 2001, Haier was the only on who won the tender of "Program for Establishment fo Blood Banks in Middle and Western China" for supplying the blood bank refrigerators.
Specialties
Temperature Control
Forced-air cooling, electrically heated balancing and microprocessor controlling system ensure a constant temperature within 41.
Digital display showing average temperature, upperand lower set points with resolution of 0.1 for observation and monitoring.
Adjustable temperature set points within 28 with an imcrement of 0.1.
Using five digital integrated sensors to display and control.
Temperature recorder to monitor safety system whole course.
Safety Control
Dual displayed operating information.
Inner-fixed storage batteryto keep displaying chamber temperature and alarming for 72 hours.
Malfunction alarms:over or under temperature, power failure, sensor error, door opening, low voltage of backup battery.
Alarm representations: buzzing, flashing, remote signal.
Double temperature recording when power fails.
Double safe operation programs(sensor defect and disorganized digits)
Ergonomic Design
Auto-defrost function to be used in high temperature and humidity area.
Safety lock to prevent unauthorized access.
Large digital display for easier obervation.
Inner light.
Caster design
Broad climatization under ambient temperature 10 32.
Transparency Design
Auto defrost technology on outer door to prevent condensed vapor under 85% humidity .
Transparent inner door.
Foaming case and transparent double glass outer door.
Model: JA DF - 80
Jove Automations Make Deep Freezer is used for plasma storage and blood products under controlled temperature with upright design.
Temperature control range from -50 degree C to -86 degree C adjustable with setting accuracy of + 0.1 degree C.
Temperature Holding Time with FULL Load: Minimum 120 Minutes in case of power failure.
Temperature Cooling Down Time With FULL Load: Maximum 300 minutes at 25 Deg C to reach below - 20 degree C.
The JA DF series have high density Polyurethane foam insulation of 125 mm to protect cabinet from ambient temperature fluctuation.
The system have hermetically sealed compressor, air cooled cascade refrigeration system with ideal running time with CFC free refrigerant and automatic defrost facility.
Access port for CO2 back up system for refrigeration.
Control System:Microprocessor Based Controller with Digital Temperature Display of Temperature in Centigrade With Microprocessor base single channel Real time Data Logger.: Temperature Range selectable with setting accuracy of + 0.1 degree C. Logging time from 1 min to 99 Min selectable. Memory of 1000 counts with alarm history. Communication port Rs. 232 or Rs 485. Centronics Port for dot matrix printer.Suitable for external monitoring. With Window base software. Analysis of word print and graph.
User parameter settings - Set point, Audio Visual Alarm system for Over and Under temperature, Buzzer Off.
Audio Visual alarm system for temperature fluctuation and power failure is independent of power Supply. Suitable battery back up of 4 hours including charger for Temperature Controller, Data logger & alarm to check temperature conditions during power failure.
Seven days inkless graphic temperature recorder with Temperature range 0 deg C to - 50 deg CPerformance is independent of electrical fluctuation. Control system with two temperature sensors & independent safety thermostat to avoid negative temperature.
Construction :
Outside :C. R. sheet of, Duly Powder Coated after Seven Tank Surface treatment.
Inside :Non- Magnetic AISI 304 Stainless Steel with properly Perforated & internal lighting.
Drawers :Rolled out type Stainless steel with inventory racks.
Copper :Interior Copper of refrigerator confirming to ASTMB Grade 68.
Door :Thickness 100 mm Polyurethane insulation.Automatic Front door closing below door opening angle of 90 with Door locks.Inner door to prevent loss of cold air.Door opening audio & visual display alarm.Lockable Castor Wheel provided for Easy Mobility for Installation.Constructed for Noise free and Vibration free performance with condensation free frame.
Input Voltage :220/240 AC Volts, 50 Hz/1Phase A Line Voltage Corrector: Input Voltage: 160V-260V, 50Hz /1 Phase.
Output Voltage :220v-240v AC Volts.
Solar driven vaccine refrigerator: HBC-60 is driven by the sun, directly from solar panels.
This appliance does not need battery storage or fuel for power. It is designed for the region
with enough sunshine and poor electricity.
Driven by solar panels without any battery, this refrigerator will not bring any negative
impact to the environment.
Features
Driven by solar power, environment friendly
No battery for storage of power
No need for power and fuel, low cost
Digital display of temperature
Easy installation
Easy maintenance, only the solar panels need to be maintained
Stainless steel interior liner
Lock design, keep safety of vaccines
| EXTERNAL DIGITAL DISPLAYThe external digital display facilitates Temperature monitoring. The display is solar driven to ensure continued temperature readings. |
High efficiency Danfoss compressor with CFC- free refrigerant. High density CFC- free insulation layer. Reasonable evaporating & compensating system to realize a superior refrigeration effect, Dual interior layer with ice packs in between to keep the chamber temperature range of 0 8 c (under the ambients temperature no higher than 43 C ) after recharging , even when the power is cut for no more than 24 hours. Comply with the standard of WHOUNICEF.
Manual defrost
These refrigerator are designed to store vaccines , pharmaceuticals, blood & so on.
These product are applicable in epidemic prevention services, clinics, hospitals, blood bank, research institute & so on.
In 2004 , Haier was the only one who won the bid of “HSCC/PUR/MMU- III/3/2002” in India to supply ice lined refrigerators of 10, 00 sets.
Refrigeration system
Specifications
|
Model no. |
HBC-200 |
HBC-70 |
|
|
Liters |
200 |
70 |
|
|
Input power |
200W |
140W |
|
|
Temp.range |
2~8 C |
||
|
Ambient temp |
10 C ~ 43 C |
||
|
Voltage |
220V ~ 240V /50Hz |
||
|
Shelves |
1 |
1 |
|
|
Exterior diamension(mm) |
1243x633x815 |
673x633x815 |
|
|
Interior diamension(mm) |
970x360x610 |
400x360x610 |
|
|
Packing diamension(mm) |
1325x760x880 |
755x760x880 |
|
|
Net/gross weight(kg) |
100/112 |
65/69 |
|
|
Container load(sets)20’/40’/40’H |
42/54/81 |
42/90/135 |
|
|
Holdover time at 43 C/32 C |
23/41/H |
22/40h |
|
| urpose & Summarze Typical installations are found in research institutes, blood banks, hospitals, epidemic prevention services, and livestock systems. SpecialtiesTemperature Control> Mechanical temperature control. > Digital temperature display. > Adjustable temperature range from -10 -25 . | |
| Refrigeration System > Highly efficient Danfoss compressor.> CFC-free refrigerants.> Fully CFC-free polyethlene insulation.> Superior cooling performance with opimized evaporator and condenser designs. Ergonomic Design > Storage Box designs for convenience of vaccines and icepack.> LED digital temperature display for easy obervation.> Wide applicable voltage tolerance of 187 VAC to 242 VAC.>Door handle design for easy operation.>Water drainage for easy cabinet cleaning. | |
| Typical installations can be found in drug stores, epidemic prevention service centers, pharmaceutical companies, and many other places. | ||||
| ||||
| Typical installations can be found in drug stores, epidemic prevention service centers, pharmaceutical companies, and many other places. | ||||
| ||||
This kind of freezer is applicable in blood banks, hospitals, epidemic prevention services, research institutes, laboratories of electronic and chemical factories, biomedical engineering institute and so on.
Temperature Control
> Microprocessor temerature control.> Digital temperature display> Ajustable temperature range from -126 to -150 with an increment of 1
Safety Control
> Malfunction alarm includes audible and flashing alarms for high temperature, low temperature, incorrect voltages setting, sensor failure, condenser efficiency defect, high ambient temperature, and power failure.> Multiple level protections:password, compressor delay start, extra high and low pressure back up.> All separate parts are safely grounded.
Cooling System
> High efficient CFC-free refrigerant cooling system.> The boiler from up to down ensure the refrigerant flowing efficiently.> Excellent cascade cooling system with dual fan whose blade is designed according to aerodynamics.> The condenser fillter with removal and easily cleaning make sure the best cooling efficiency.
Ergonomic Design
> Applicable to use far away from the working ambient temperature within 1025.> Gravis type added self-locked caster, it is convenient for moving.> Low temperature level compressor control only if need to avoid mistake for a longer life.> It is easy to wash because of Inner round angle dealing design.> Optional LN2 backup system makes it convenient to use under emergency situation, make the operation safe.> Optional temperature record instrument, so it is convenient to record temperature and save forever.> Optional intelligent monitoring system, you can record the data and monitor on the the computer and realize remote supervising.
Pre freezing Glycol bath is meant to freeze materials in round bottom flaks before loading on the freeze dryer. The pre-freezer bath can achieve a temperature range of-40C and has rotation mechanism for a pair of flasks.
| Product code | Description |
| FMF B040 | Pre-freezing Glycol Bath |
This product is designed to store vaccines, blood plasma, biological materials etc. Applications could be found in the electronic and chemical laboratories epidemic prevention, hospitals, animal husbandry areas, blood banks and research institutes
PerformanceMicroprocessor control, digital display of temperatureImported high efficiency Compressor, CFC-free RefrigerantFamous brand Fan, high density insulation foamEvaporator and Condenser system, guarantee freezing efficiency and uniformity of temperatureErgonomic design, more reliable and easy to operate
Temperature ControlMicroprocessor control, digital display of temperature, temperature in cabinet adjustable range: -20oC to -40oCAlarm when exceeding temperature range, memory function in case of power failure
Safety SystemAlarm conditions ( Higher or lower temperature alarm, Sensor malfunction alarm, power off alarm)Two kinds of alarm indicators ( Audible buzzing alarm, Visual flashing alarm)Start up delay protection.
Refrigeration SystemDanfoss compressorCFC-free refrigerantGermany EBM condenser fanHigh density insulation foamEvaporator as the shelves, freezing faster, better performance on conformity of temperature.
Ergonomic DesignDouble doors design with lock respectively, more convenient to store in assortment or more usersIngenious design of lock, adjustable on distance and power, can be fixed double padlock, more safety and reliableDoor handle, easier to open and closeDrawer, more convenient to useBroad voltage tolerance design, applicable for voltage range 198v238vLED digital display for easy observationEquipped with lockable casters, easy to moveAnti-corruption step cabinet design, applicable for various of baskets
Spin Freezer is useful for freezing & primary drying of samples in glass ampoules. By spinning ampoules, samples are frozen on the base unit without the need for pre-freezing. The centrifugal force holds the liquid sample in position and prevents frothing and bubbling during evaporation as the sample solidifies and sublimes. The spin freezer has an independent power supply and includes a timer to prevent spinner overrun after freezing. Removable rotor plates provided with system accept 5 different sized ampoules.