We are leaders in the market for providing best range of Blood Coagulometer, Esr Analyser, Fully Automated Haematology Analyser, Hemoglobin Analyser and Coagulometer
The coagulometer adopt the word approved coagulometer test method;
The CPU adopt ARM technology to measure the motion of the magnetic ball to work out the coagulation time.
It can perform multiparameter simultaneously with better accuracy precision & repetition.
Performance
SR Analyser
Features
> Infrared optical detection technology.> Automatically scanning blood cells and location of the plasma interface from time to time with accurate positioning.> Internal thermal printer, ESR curve display and printout> Automatically amending the ESR results under the detecting temperature (15 C 32 C) to the ESR values at 18 C closely related with westergren results.> The results are not interfered by pharmacological samples such as jaundice, hemolysis or chyle
3 Part differential Cell Counters
General Technical Specifications Principles Electrical resistance for counting and SFT method for hemoglobin. Parameters WBC, Lymph, Mid, Gran, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, WBC Histogram, RBC Histogram, PLT Histogram, P-LCR. Working mode Single counting pathway + Independent HGB detection system Operating mode Color Windows interface, figure button, mouse input Specification 23 parameters, with 3 part WBC differntial Aperture Diameter 70um 10 uL sampler volume Memory for 30, 000 results including histograms Throughput: 35 samples/hour Automatic and manual calibration Automatic dilution when power on/off High voltage cleaning after each measurement QC mode: X-B, L-J curve, SD, CV Interface 1 parallel interface, 2 USB
General Technical Specifications
Principles
Electrical resistance for counting and SPT methods for hemoglobin.
Parameters
WBC, Lymph, Mid Gran, Lymph %, Mid %, Gran %, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, PLT, MPV, PDW, PCT, WBC Histrogram, RBC Histrogram, PLT Histrogram, P-LCR.
Working mode
Double counting pathway + independent HGB detection systems
Operating mode
Color Windows interface, figure button, mouse input.
Interface
1 parallel interface, 2 USB interfaces, 2 RS232 interfaces (with net), 1 VGA interface.
Specification
> 23 parameters with 3 part WBC differential> Aperture Diameter volume> 10 ul sampler volume> Memory for 30, 000 results including histograms> Throughput : 60 samples / hour> Automatic and manual calibration> Auomatic dilution when power on / off> High voltage clednind after each measurement> QC mode : X-B, L-J curve, SD, CV.
| Operating Environment Temperature 15 degree C 30 degree CHumidity 10% 85 % Prinout Thremal recorder, printerOptional external printer Display Large color LCD display, resolutions 640 x 480 dot Power Requirement 175-265v 50 / 60HZ Weight 25 Kg | ||
|
Parameter |
Linearity range |
Precision |
|
WBC |
0.5~99.9x10/L |
CV<2.0% |
|
RBC |
0.2~9.99x10/L |
CV<1.5% |
|
HGB |
1.0~299.9 g/L |
CV<1.5% |
|
MCV |
40~200.0 fL |
CV<0.5% |
|
PLT |
0~ 999x10/L |
CV<4.0% |
Features
> Measures the HbA1c (Hemoglobin A1c) and gets the average glucose level for the recent 2-3 months.> A more accurate data than prevoius measuring systems, makes a more convinient glucose control, > A one steps measuring system has overcome the complicated hospital measuring equipments> Developed to be portable / home care system, measurig economically