Our Products
Our product range contains a wide range of Blood Coagulometer, Esr Analyser, Fully Automated Haematology Analyser, Hemoglobin Analyser and Coagulometer
The coagulometer adopt the word approved coagulometer test method;
The CPU adopt ARM technology to measure the motion of the magnetic ball to work out the coagulation time.
It can perform multiparameter simultaneously with better accuracy precision & repetition.
Performance
SR Analyser
Features
> Infrared optical detection technology.> Automatically scanning blood cells and location of the plasma interface from time to time with accurate positioning.> Internal thermal printer, ESR curve display and printout> Automatically amending the ESR results under the detecting temperature (15 C 32 C) to the ESR values at 18 C closely related with westergren results.> The results are not interfered by pharmacological samples such as jaundice, hemolysis or chyle
3 Part differential Cell Counters
General Technical Specifications Principles Electrical resistance for counting and SFT method for hemoglobin. Parameters WBC, Lymph, Mid, Gran, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, WBC Histogram, RBC Histogram, PLT Histogram, P-LCR. Working mode Single counting pathway + Independent HGB detection system Operating mode Color Windows interface, figure button, mouse input Specification 23 parameters, with 3 part WBC differntial Aperture Diameter 70um 10 uL sampler volume Memory for 30, 000 results including histograms Throughput: 35 samples/hour Automatic and manual calibration Automatic dilution when power on/off High voltage cleaning after each measurement QC mode: X-B, L-J curve, SD, CV Interface 1 parallel interface, 2 USB
General Technical Specifications
Principles
Electrical resistance for counting and SPT methods for hemoglobin.
Parameters
WBC, Lymph, Mid Gran, Lymph %, Mid %, Gran %, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, PLT, MPV, PDW, PCT, WBC Histrogram, RBC Histrogram, PLT Histrogram, P-LCR.
Working mode
Double counting pathway + independent HGB detection systems
Operating mode
Color Windows interface, figure button, mouse input.
Interface
1 parallel interface, 2 USB interfaces, 2 RS232 interfaces (with net), 1 VGA interface.
Specification
> 23 parameters with 3 part WBC differential> Aperture Diameter volume> 10 ul sampler volume> Memory for 30, 000 results including histograms> Throughput : 60 samples / hour> Automatic and manual calibration> Auomatic dilution when power on / off> High voltage clednind after each measurement> QC mode : X-B, L-J curve, SD, CV.
| Operating Environment Temperature 15 degree C 30 degree CHumidity 10% 85 % Prinout Thremal recorder, printerOptional external printer Display Large color LCD display, resolutions 640 x 480 dot Power Requirement 175-265v 50 / 60HZ Weight 25 Kg | ||
|
Parameter |
Linearity range |
Precision |
|
WBC |
0.5~99.9x10/L |
CV<2.0% |
|
RBC |
0.2~9.99x10/L |
CV<1.5% |
|
HGB |
1.0~299.9 g/L |
CV<1.5% |
|
MCV |
40~200.0 fL |
CV<0.5% |
|
PLT |
0~ 999x10/L |
CV<4.0% |
Features
> Measures the HbA1c (Hemoglobin A1c) and gets the average glucose level for the recent 2-3 months.> A more accurate data than prevoius measuring systems, makes a more convinient glucose control, > A one steps measuring system has overcome the complicated hospital measuring equipments> Developed to be portable / home care system, measurig economically