My ExportersIndia

For Buyer

For Seller

For Help

East Advance Technology Co. Ltd.
Write a Review

Our Products

  1. Power Connectors 6 Products available
  2. Computer Hardware & Peripherals 6 Products available
  3. Industrial Automation System 4 Products available
  4. Calibrators And Monitoring Systems 3 Products available
  5. Electronic Components 3 Products available
  6. Epoxy Coatings 2 Products available
  7. Memory Card 2 Products available
  8. Windmills 1 Products available
  9. Power Supply System 1 Products available
  10. Cables And Wire Accessories 1 Products available
  11. Network Switch 1 Products available
  12. Telecommunication Equipments 1 Products available
  13. Screws 1 Products available
  14. Starters 1 Products available
  15. Vehicle Chassis 1 Products available
  16. Electric & Home Appliances 1 Products available
  17. Pallets, Crates & Trays 1 Products available
  18. Instrumentation Equipment 1 Products available
  19. Solar Products 1 Products available
  20. Others Products 61 Products available

Epoxy Coatings

We offer a complete product range of Siemens - (6ag1222-1hf30-2xb0), Siplus - (s7-1200 Sm1222 8rly Conformal Coating) and Siemens - (6ag1222-1hh30-2xb0), Siplus - (s7-1200 Sm1222 16rly Conformal Coating)

Siemens - (6ag1222-1hf30-2xb0), Siplus - (s7-1200 Sm1222 8rly Conformal Coating)

17,215.82 / 181 181 Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Siemens
  • TYPE PLC
Supply voltage permissible range, lower limit (dc) 5 v permissible range, upper limit (dc) 30 v input current from backplane bus 5 v dc, max. 120 ma digital inputs from load voltage l+ (without load), max. 11 marelay coil power losses power loss, typ. 4.5 w digital inputs numberbinary inputs 0 digital outputs numberbinary outputs 8 in groups of 2 functionalityshort-circuit strength no; to be provided externally switching capacity of the outputs with resistive load, max. 2 a on lamp load, max. 30 w dc ; 200 w ac output voltage rated value (ac) 5 to 250 v ac rated value (dc) 5 to 30 v dc output current for signal "1" permissible range, max. 2 a output delay with resistive load 0 to "1", max. 10 ms 1 to "0", max. 10 ms aggregate current of outputs (per group) horizontal installation up to 50 c, max. 10 a; current per mass relay outputs number of relay outputs 8 rated input voltage of relay coil l+ (dc) 24 v number of operating cycles, max. Mechanically 10 million, at rated load voltage 100, 000 switching capacity of contacts with inductive load, max. 2 a on lamp load, max. 30 w dc ; 200 w ac switching frequencycontactsat ohmic loadmaximum 2 a cable length cable length, shielded, max. 500 m cable length unshielded, max. 150 m interruptsdiagnosticsstatus information alarms alarms yes diagnostic alarm yes diagnostic messages diagnostic functions yes diagnostics indication led for status of the outputs yes for maintenance yes status indicator digital output (green) yes galvanic isolation galvanic isolation digital outputs between the channels relay between the channels, in groups of 2 between the channels and the backplane bus 1500 v ac for 1 minute degree and class of protection ip20 yes standards, approvals, certificates ce mark yes fm approval yes ambient conditions extended ambient conditions relative to ambient temperature-atmospheric pressure-installation altitude tmin . Tmax at 1080 hpa . 795 hpa (-1000 m . +2000 m) tmin . (tmax - 10k) at 795 hpa . 658 hpa (+2000 m . +3500 m) tmin . (tmax - 20k) at 658 hpa . 540 hpa (+3500 m . +5000 m) relative humidity with condensation maximum 100 %; relative humidity, incl. Condensation frost permitted (no commissioning under condensation conditions) resistance to biologically active substances conformity with en 60721-3-3 yes; , class 3b2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! to chemically active substances conformity with en 60721-3-3 yes; , class 3c4 incl. Salt spray. The supplied connector covers must remain on the unused interfaces during operation! to mechanically active substances conformity with en 60721-3-3 yes; , class 3s4 incl. Sand, dust. The supplied connector covers must remain on the unused interfaces during operation! climatic and mechanical conditions for storage and transport climatic conditions for storage and transport free fall drop height, max. (in packaging) 0.3 m; five times, in dispatch package temperature permissible temperature range -40 c to +70 c mechanical and climatic conditions during operation climatic conditions in operation temperature min. -25 c; = tmin max. 70 c; = tmax connection method required front connector yes mechanicsmaterial type of housing (front) plastic yes dimensions width 45 mm height 100 mm depth 75 mm weight weight, approx. 190 g

Additional Information:

Payment Terms : T/T, Western Union

Packaging Details : 100% Siemens Original and New.
Standard Air Conditioning Packing

View Complete Details

Siemens - (6ag1222-1hh30-2xb0), Siplus - (s7-1200 Sm1222 16rly Conformal Coating)

27,342.77 / 287 287 Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Siemens
  • TYPE PLC
Supply voltage permissible range, lower limit (dc) 5 v permissible range, upper limit (dc) 30 v input current from backplane bus 5 v dc, max. 135 ma digital inputs from load voltage l+ (without load), max. 11 marelay coil power losses power loss, typ. 8.5 w digital inputs numberbinary inputs 0 digital outputs numberbinary outputs 16 in groups of 1 functionalityshort-circuit strength no; to be provided externally switching capacity of the outputs with resistive load, max. 2 a on lamp load, max. 30 w dc ; 200 w ac output voltage rated value (ac) 5 to 250 v ac rated value (dc) 5 to 30 v dc output current for signal "1" permissible range, max. 2 a output delay with resistive load 0 to "1", max. 10 ms 1 to "0", max. 10 ms aggregate current of outputs (per group) horizontal installation up to 50 c, max. 10 a; current per mass relay outputs number of relay outputs 16 rated input voltage of relay coil l+ (dc) 24 v number of operating cycles, max. Mechanically 10 million, at rated load voltage 100, 000 switching capacity of contacts with inductive load, max. 2 a on lamp load, max. 30 w dc ; 200 w ac switching frequencycontactsat ohmic loadmaximum 2 a cable length cable length, shielded, max. 500 m cable length unshielded, max. 150 m interruptsdiagnosticsstatus information alarms alarms yes diagnostic alarm yes diagnostic messages diagnostic functions yes diagnostics indication led for status of the outputs yes for maintenance yes status indicator digital output (green) yes galvanic isolation galvanic isolation digital outputs between the channels relay between the channels, in groups of 4 between the channels and the backplane bus 1500 v ac for 1 minute ambient conditions extended ambient conditions relative to ambient temperature-atmospheric pressure-installation altitude tmin . Tmax at 1080 hpa . 795 hpa (-1000 m . +2000 m) tmin . (tmax - 10k) at 795 hpa . 658 hpa (+2000 m . +3500 m) tmin . (tmax - 20k) at 658 hpa . 540 hpa (+3500 m . +5000 m) relative humidity with condensation maximum 100 %; relative humidity, incl. Condensation frost permitted (no commissioning under condensation conditions) resistance to biologically active substances conformity with en 60721-3-3 yes; , class 3b2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! to chemically active substances conformity with en 60721-3-3 yes; , class 3c4 incl. Salt spray. The supplied connector covers must remain on the unused interfaces during operation! to mechanically active substances conformity with en 60721-3-3 yes; , class 3s4 incl. Sand, dust. The supplied connector covers must remain on the unused interfaces during operation! climatic and mechanical conditions for storage and transport climatic conditions for storage and transport free fall drop height, max. (in packaging) 0.3 m; five times, in dispatch package temperature permissible temperature range -40 c to +70 c mechanical and climatic conditions during operation climatic conditions in operation temperature min. -25 c; = tmin max. 70 c; = tmax degree and class of protection ip20 yes standards, approvals, certificates ce mark yes fm approval yes connection method required front connector yes mechanicsmaterial type of housing (front) plastic yes dimensions width 45 mm height 100 mm depth 75 mm weight weight, approx. 260 g

Additional Information:

Payment Terms : T/T, Western Union

Packaging Details : 100% Siemens Original and New.
Standard Air Conditioning Packing

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us