My ExportersIndia

For Buyer

For Seller

For Help

Our Product / Services

  1. Flow Meters 29 Products available
  2. Transmitter Device 9 Products available
  3. Level Transmitters 7 Products available
  4. Level Switches 7 Products available
  5. Digital Indicator 5 Products available
  6. Conductivity Meter 4 Products available
  7. Pressure Transmitter 3 Products available
  8. Pressure Switches 3 Products available
  9. High Voltage Circuit Breaker 3 Products available
  10. Gas Analyzers 2 Products available
  11. Switches And Switch Boxes 2 Products available
  12. Communications Transmitters 2 Products available
  13. Differential Pressure Gauge 1 Products available
  14. Level Sensors 1 Products available
  15. Pressure Gauges 1 Products available
  16. Sensor Switches 1 Products available
  17. Temperature Gauges 1 Products available
  18. Tube Fittings 1 Products available
  19. Temperature Switches 1 Products available
  20. Flow Gauge 1 Products available
  21. Flanges 1 Products available
  22. Flow Switches 1 Products available
  23. Weather Instruments 1 Products available
  24. Digital Panel Meters 1 Products available
  25. Data Loggers 1 Products available
  26. Electronic Transformers 1 Products available
  27. Power Supply Accessories 1 Products available
  28. PH Meter 1 Products available
  29. Digital Scanner 1 Products available
  30. Temperature Controller 1 Products available
  31. Amplifier 1 Products available
  32. Temperature Sensors 1 Products available
  33. Instrument Calibration & Testing 1 Services available
  34. Calibration Services 1 Services available

Conductivity Meter

Our Complete range of products are Ctt 100S Toroidal Conductivity Transmitter, CT100S Digital Conductivity Transmitter, TS2000 CT Conductivity Transmitter and Lcs 02 Industrial Conductivity Level Transmitter.

CTT 100S Toroidal Conductivity Transmitter

  • Min. Order (MOQ) 10 Piece
  • Type Toroidal Conductivity / TDS Transmitter
  • Features On-line Conductivity Measurement, Non-volatile Memory Retains Settings During Power Failure, 4-20 MA DC Output / 4-20 MA With HART, Auto/manual Temperature Compensation, Clear LCD Display For Online Indication, Simple And User-friendly Operating Interface, 2-wi
  • Input Type Toroidal Conductivity Electrode
  • Calibration Range 200 To 2, 000, 000 µS/cm
  • Power Supply 24V DC, 2-wire Loop Powered
  • Power Consumption < 50 MW
  • Display Type LCD With Backlight
  • output signal 4-20 MA DC / 4-20 MA With HART
  • Transmitter Accuracy ±0.25% F.S.
  • Response Time < 500 MSec
  • Temperature Coefficient ±0.01% Per °C
  • Humidity 5% To 95% RH
  • Isolation 1.4 KV Between Input, Output & Power
  • Sensor Connection BNC Connector, Terminal Connection
  • Conduit Entry M20 X 1.5 (F), 1/2
  • Dimensions 155 Mm (H) X 105 Mm (W) X 130 Mm (D)
  • Housing Cast Aluminum With Epoxy Coating (NEMA 4X) / SS316
  • Protection Class Flameproof CMRI IA IIB / Weatherproof IP-65
  • Weight Approx. 1 Kg

CTT 100S Toroidal Conductivity / TDS Transmitter Description

Electronet Series CTT 100S is an advanced Toroidal Conductivity / TDS Transmitter designed for a wide range of industrial applications. It accepts input from a Toroidal Conductivity Electrode and converts the conductivity signal into a reliable 420 mA output (with optional HART).
The unit features an LCD display for real-time conductivity indication and offers easily accessible Zero/Span adjustments. Its rugged construction and precise measurement performance make it ideal for continuous online monitoring.

Features

  • On-line conductivity measurement

  • Non-volatile memory retains settings during power failure

  • 420 mA DC output / 420 mA with HART (Generic)

  • Auto / manual temperature compensation

  • Clear LCD display for online indication

  • Simple and user-friendly operating interface

  • 2-wire loop-powered system

  • Suitable for harsh industrial applications

Technical Specifications Input

  • Type: Toroidal Conductivity Electrode

  • Calibration Range: 200 to 2, 000, 000 S/cm

Power

  • Supply: 24V DC, 2-wire loop powered

  • Power Consumption: < 50 mW

Display

  • Type: LCD with backlight

Output

  • Signal: 420 mA DC / 420 mA with HART (Generic)

  • Transmitter Accuracy: 0.25% F.S.

  • Response Time: < 500 mSec

  • Temperature Coefficient: 0.01% per C

Temperature Compensation

  • Sensor: RTD PT-100 / PT-1000

Environmental Conditions

  • Ambient Temperature: Suitable for industrial environments

  • Humidity: 5% to 95% RH (non-condensing at 25C)

  • Isolation: 1.4 kV between input, output & power

Connections

  • Sensor Connection:

    1. BNC connector

    2. Terminal connection

  • Conduit Entry:

    1. M20 1.5 (F)

    2. " NPT (F)

Physical

  • Dimensions: 155 mm (H) 105 mm (W) 130 mm (D)

  • Mounting: 2" pipe mounting

  • Housing: Cast aluminum with epoxy coating (NEMA 4X) / SS316

  • Protection Class: Flameproof CMRI IA IIB / Weatherproof IP-65

  • Weight: Approx. 1 kg

Optional

  • Flow-through assembly: SS316 / PP

Product PDF


Download Detail File : Click Here
View Complete Details

CT100S Digital Conductivity Transmitter

  • Min. Order (MOQ) 10 Piece
  • Type Conductivity Transmitter
  • Input Type From Conductivity Electrode
  • Output 4–20 MA DC / 4–20 MA With HART (Generic)
  • Display LCD With Backlight
  • Power Supply 24V DC, Two-wire Loop Powered
  • Power Consumption < 50 MW
  • Accuracy ±0.25% F.S
  • Response Time < 500 MSec
  • Isolation 1.4 KV Between Input, Output & Power Supply
  • Temperature Coefficient ±0.01% Per °C
  • Temperature Compensation RTD PT-100 / PT-1000 (Auto / Manual)
  • Ambient Temperature −20°C To 55°C
  • Ambient Humidity 5% To 95% Non-condensing
  • Dimensions 155 Mm (H) × 105 Mm (W) × 130 Mm (D)
  • Protection Class Flameproof CMRI IIA IIB / Weatherproof IP-67
  • Weight Approx. 1 Kg
  • Series Electronet Series CT-100S
  • Flow Through Assembly SS316 / PP
CT-100S Conductivity Transmitter Description

Electronet SeriesCT-100Sare high-performance conductivity transmitters designed for a wide range of industrial applications.
They accept input from conductivity electrodes with cell constants0.01 / 0.1 / 1, and convert the conductivity signal into a standard420 mA output.
The unit provides clear on-line indication through a backlit LCD. Span and zero adjustments are easily accessible, ensuring user-friendly operation and quick calibration.

Features
  • On-line measurement

  • Non-volatile memory retains program settings during power failures

  • 420 mA DC output / 420 mA with HART (Generic)

  • Auto / Manual temperature compensation

  • On-line indication through LCD display

  • Simple operating interface

  • 2-wire system

Technical Specifications

Input
  • Type of Input: From conductivity electrode

  • Cell Constant: 0.01 / 0.1 / 1

  • Calibration Range:

    • 0 to 99.99 S/cm (Cell constant 0.01)

    • 0 to 999.99 S/cm (Cell constant 0.1)

    • 0 to 9999.99 S/cm (Cell constant 1)

Electrical
  • Power Supply: 24V DC, two-wire loop powered

  • Power Consumption: < 50 mW

  • Output: 420 mA DC / 420 mA with HART (Generic)

  • Accuracy: 0.25% F.S

  • Response Time: < 500 mSec

  • Isolation: 1.4 kV between input, output & power supply

Display & Compensation
  • Display: LCD with backlight

  • Temperature Coefficient: 0.01% per C

  • Temperature Compensation: RTD PT-100 / PT-1000 (Auto / Manual)

Environmental Conditions
  • Ambient Temperature: 20C to 55C

  • Ambient Humidity: 5% to 95% non-condensing

Connections
  • Sensor Connection:

    1. Through BNC connector

    2. Through terminals

  • Conduit Entry:

    1. M20 x 1.5 (F)

    2. " NPT (F)

Mechanical

  • Dimensions: 155 mm (H) 105 mm (W) 130 mm (D)

  • Mounting: 2" pipe mounting

  • Housing: Cast aluminum with epoxy coating, NEMA 4X / SS316

  • Protection Class: Flameproof CMRI IIA IIB / Weatherproof IP-67

  • Weight: Approx. 1 kg

  • Flow Through Assembly (Optional): SS316 / PP

Product PDF


Download Detail File : Click Here
View Complete Details

TS2000 CT Conductivity Transmitter

  • Min. Order (MOQ) 10 Piece
  • Color Silver
  • Type Conductivity Transmitter
  • Material SS-316
  • Features High Corrosion Resistance, IP-68 Protection, RS-485 Communication, 4-20 MA Output, Backlit LCD Display
  • Power Supply 18-36V DC
  • Display Local LCD With Backlit
  • Output 4-20 MA
  • Communication RS-485 MODBUS RTU
  • Accuracy +/-0.25%F. S.
  • Response Time 1Sec
  • Temperature Compensation RTD PT-100
  • Isolation 1.4 KV
  • Electrical Connections M12 Connector
  • Protection Class Weather Proof IP-68
  • Ambient Temperature 55-316°C
  • Ambient Humidity 5 To 95% Non-condensing At 25°C
TS2000 CT Conductivity Transmitter Switch Description

The TS2000 CT is an advanced Conductivity Transmitter with an optional switching output, designed for reliable online conductivity measurement in industrial environments. With its SS-316 enclosure, IP-68 protection, and support for both analog and MODBUS RTU communication, it offers durability, precision, and easy integration with modern control systems.
Its backlit LCD display, versatile mounting options, and support for remote or integral sensors make it ideal for harsh and demanding applications.

Features
  • SS-316 enclosure with high corrosion resistance

  • IP-68 protection for harsh environments

  • RS-485 (MODBUS RTU) communication (optional)

  • 420 mA analog output

  • Bright backlit LCD display

  • Supports Remote / Integral Sensor connection

  • Rugged design for industrial applications

Technical Specifications Input
  • Type: From Conductivity Electrode

  • Cell Constant: 0.01 / 0.1 / 1.0

Calibration Range (Factory Calibrated)
  • Cell Constant 0.01: 0 to 99.99 S/cm

  • Cell Constant 0.1: 0 to 999.99 S/cm

  • Cell Constant 1.0: 0 to 9999.99 S/cm

Measuring Span
  • Maximum: 9999.99 S/cm

  • Minimum: 99.99 S/cm

Power
  • Supply: 1836V DC

  • Power Consumption: < 5W

Display
  • Type: Backlit LCD

Output
  • Analog Output: 420 mA

  • Relay Output: 1 Relay (Optional)

  • Communication: RS-485 (MODBUS RTU) (Optional)

Performance
  • Transmitter Accuracy: 0.25% F.S.

  • Response Time: 1 Second

  • Temperature Compensation: RTD PT-100

  • Isolation: 1.4 kV between Input, Output & Power

Connections
  • Sensor Connection: Remote or Integral

  • Electrical Connection: M12 Connector

Mounting
  • 2" Pipe Mounting / Direct Line Mounting

Environmental
  • Protection: Weatherproof IP-68

  • Electronics Enclosure: SS-316

  • Ambient Temperature: 20C to +60C

  • Humidity: 5% to 95% RH (Non-condensing at 25C)

Optional

  • Flow-through Assembly: SS-316 / PP

Product PDF


Download Detail File : Click Here
View Complete Details

LCS 02 Industrial Conductivity Level Transmitter

  • Min. Order (MOQ) 10 Piece
  • Accuracy ±5 Mm With Respect To Set Point
  • Type Conductivity Type Level Switch
  • Response Time < 1 Second
  • Mounting Tank Mounted, Mounted Over Open Sumps
  • Process Pressure Up To 10 Kg/cm² (max)
  • Probe Length Max 3000 Mm
  • Probe Diameter 15 Mm To 25 Mm
  • Process Temperature Up To 120°C (max)
  • Probe Material SS316
  • Electrode Insulation Material PTFE
  • Electrical Connection DIN 43650 Connector
  • Switch Differential Fixed ±10 Mm
  • Probe Type Single Rod, Coaxial

Features

  • Switch output with potential-free relay contact

  • Simple, low-cost & reliable operation

  • Electronics protection class: Weatherproof IP67

  • Trouble-free operation for conductive / non-conductive liquids and slurries

Electronet series LCS-02 are conductivity-type level switches used for level measurement of conductive liquids.
The probe works on the principle of variation in electrical resistance between the reference electrode and the level control electrode.

When the medium covers the electrodes, the change in resistance is detected as a level signal.

  • If the tank wall is electrically conductive, it can serve as the reference electrode.

  • For tanks made of plastic, concrete, or other non-conductive materials, an additional reference electrode is required.

Technical Specifications Type

  1. Single Point Conductivity Type Level Switch

  2. Two Point Conductivity Type Level Switch

  3. Three Point Conductivity Type Level Switch

  4. Four Point Conductivity Type Level Switch

Probe Length

  • As per requirement (Rigid type, max 3000 mm)

Probe Diameter

  • 15 mm to 25 mm

Process Temperature

  • Up to 120C (max)

Process Pressure

  • Up to 10 kg/cm (max)

Probe Material (MOC)

  • SS316 / SS316L

Type of Sensing Electrode

  • Rigid Type

  • Flexible Type

Electrode Insulation Material

  • PTFE

Electronics Enclosure (MOC)

  1. Die-cast Aluminium

  2. SS304

Seals / Gaskets

  • EPDM / PEEK

Electrical Connection

  • DIN 43650 Connector

Type of Output

  • Resistance Value

Accuracy

  • 5 mm with respect to set point

Repeatability

  • 1 mm with respect to set point

Response Time

  • < 1 second

Switch Differential

  • Fixed 10 mm

Probe Type

  1. Single Rod

  2. Coaxial

Enclosure Protection Class

  1. SS Enclosure: IP65 or higher (as per IEC-60529)

  2. Die-cast Aluminium Enclosure: Weatherproof IP67

Process Connection

  1. " BSP(M)

  2. 1" BSP(M)

  3. 2" PVC Flanged

  4. 2" SS316 Flanged

  5. M20 x 1.5 (M)

  6. M39 x 3 (M)

Mounting

  • Tank Mounted

  • Mounted over open sumps

Ambient Conditions

  • Temperature: 0 to 75C

  • Humidity: 0 to 98% non-condensing at 35C

Product PDF


Download Detail File : Click Here
View Complete Details