Our Product / Services
Our Complete range of products are Asionic 200 Cf Clamp-On Ultrasonic Flow Meter, Elmag 200W Electromagnetic Flow Meter, Asionic 400 4 Multipath Ultrasonic Flow Meter, Asionic 200 Cfb Clamp-On Ultrasonic Flow Meter and Venturi Tube.
Description
ASIONIC™ 200 CF Clamp-On Ultrasonic Flow Meters are designed for accurate flow measurement of liquids in industrial applications. Since the sensors are clamped directly onto the outer surface of the pipe, the system eliminates all process compatibility issues associated with in-line flow meters.
The flow meter operates on Transit Time Measurement Technology, where ultrasonic signals are sent with and against the flow direction. By comparing the travel times, the system accurately calculates fluid velocity and volumetric flow rate. Sonic properties of the pipe and fluid are factored in, ensuring highly repeatable accuracy.
ASIONIC™ 200 CF is ideal for users requiring a non-intrusive, easy-to-install solution that maintains precise flow measurement for clean liquids — especially in applications where:
In-line meters were not previously installed,
Large pipe diameters exist, or
Pipe materials are exotic or incompatible with in-line technologies.
The clamp-on design allows installation without stopping the flow or cutting the pipeline, making it suitable for both retrofits and new process setups.
Features
Ultrasonic measurement using Transit Time Technology
Easy installation — no need to cut the pipe or stop the flow
External transducers require no periodic cleaning
No pressure drop or energy loss
Bi-directional flow measurement
Suitable for a wide range of pipe diameters
Portable or fixed installation options
Compact and lightweight design
Inbuilt data logging
Technical Specifications Performance Characteristics
Media: Sonically conductive liquids
Sensing Method: Differential transit-time (direct or reflect mode)
Viscosity: Up to 200 cP
Turbidity: <10, 000 ppm with low air bubble content
Flow Velocity Range: –12 m/s to +12 m/s (40 ft/s)
Accuracy*: ±2% of F.S. + 5 mm/sec
(For velocity range 0.3 m/s to 6 or 12 m/s)
Line Size:
50 NB to 100 NB
125 NB to 300 NB
For higher line sizes, consult factory
Acoustic Paths: Single path
Display: LCD
Communication Interface: RS-485
Data Logger: Internal data logging
Electrical Specifications
Power Supply: 24V DC
Outputs:
4–20 mA
Pulse (Open Collector)
Environmental Conditions
Ambient Temperature: –20°C to +60°C
Ambient Humidity: 5–95% RH (non-condensing)
Operating Temperature – Transducer:
Standard: –40°C to +80°C
Optional: –40°C to +150°C
Operating Temperature – Electronics: –10°C to +60°C
Mechanical Specifications
Pipe Size Compatibility: 50 NB (2”) to 300 NB (12”)
Pipe Wall Thickness: <10 mm
Pipe Material Compatibility: MS / SS / Cast Iron / Plastic
Sensor Cable:
Encapsulated design
Standard length: 5 meters
Sensor Mounting Method: “V” method
Transmitter Mounting: Pipe-mounted / wall-mounted
Electronic Protection: Field-mount Weatherproof IP-67
Configuration Details
Media Type: Sonically conductive liquids
Sensor Type: Clamp-on
Certification: CE
LMAG-200W Zero Upstream/Downstream Electromagnetic Flow Meter Features
No inlet or outlet straight-run requirement (0 DN)
Full-bore design for unobstructed flow
Advanced signal processing for enhanced stability
No tube restriction and zero pressure loss
Multiple electrodes for higher accuracy
Stable and accurate long-term performance
Reliable, cost-efficient, and flexible flow measurement solution
Description
The Electronet ELMAG-200W is a next-generation zero-run electromagnetic flow meter engineered for accurate and maintenance-free flow measurement without the need for upstream or downstream straight pipe runs.
Utilizing Faradays Law of Electromagnetic Induction, the ELMAG-200W delivers high accuracy, exceptional turndown capability, and stable operation even in challenging water and wastewater applications.
Its full-bore construction ensures zero pressure loss, while the absence of moving parts minimizes maintenance requirements.
Equipped with a robust selection of liners and electrodes, along with an integrated local display, it offers one of the most user-friendly and efficient flow measurement solutions availablewithout requiring external software or hardware.
Typical applications include:
Water distribution
Wastewater treatment
Industrial utility monitoring
Irrigation and municipal systems
Technical Specifications Performance Characteristics
Nominal Diameters: 50 NB to 600 NB (2" to 24")
Process Connections: EN (DIN), ASME, JIS, AWWA flanges
Process Temperature: 20 to +90C (4 to +194F)
Degree of Protection: IP67 (Type 4X enclosure)
Measured Error:
Standard: 0.5% of M.V.
Optional: 0.3% of M.V.
Directly after bend: 0.5% of M.V.
Turndown Ratio: 100:1
Electrical Conductivity Required: 25 S/cm
Inlet/Outlet Runs: 0 DN (No straight run required)
Measured Variables: Volume flow, conductivity, mass flow
Max Process Pressure: PN40 / Class 300 / 20K
Materials Liner Options
Polyurethane
Hard Rubber
PTFE
Liner Temperature Limits
Hard rubber: 0 to +80C (+32 to +176F)
Polyurethane: 20 to +50C (4 to +122F)
PTFE: 20 to +180C (4 to +356F)
Electrodes
SS316L
Hastelloy C-22
Tantalum
Platinum
Wetted Parts Temperature (Ambient)
Hard rubber: 0 to +80C
Polyurethane: 20 to +50C
Additional Technical Specifications Velocity Range
0.3 m/s 2.5 m/s (up to max. 10 m/s)
Housing Materials
Sensor Housing: MS / SS304 / SS316
Transmitter Housing: Aluminium Die-Cast / SS316
Protection Classes
Compact Version: IP66 / IP67
Remote Sensor (Standard): IP66 / IP67
Remote Sensor (Optional): IP68 with protective varnish
Remote Transmitter: IP66 / IP67
Display & Operation
2-line backlit LCD display
Touch operation (from outside)
Full configuration through local display
Integrated data logger
Outputs
3 Output Channels Including:
020 mA / 420 mA with Generic HART (Active)
Pulse / Frequency / Switch Output (Passive)
Additional Pulse / Frequency Output (Passive)
Digital Communication
HART
MODBUS RS-485
Power Supply
100240 V AC
24 V DC
Approvals & Calibration
Calibration performed at ISO/IEC 17025 accredited facilities
Material certificates 3.1 available
Sensor Features
Flexible connections
Corrosion-protected structure (EN ISO 12944)
IP68 protection option available
Transmitter Features
Backlit display for safe and easy operation
Rugged and durable housing
Integrated data logger for process recording
Electronet Series ASIONIC 400-4 Ultrasonic Flow Meters offer the flexibility to install a highly reliable flow measurement system virtually anywhere without compromising accuracy or performance. These meters are extremely easy to use, simple to install, and require no regular maintenance.
Designed for both industrial and domestic applications, they are ideal for:
Municipal and industrial water supply
Cooling tower systems
Water treatment plants
The integrated LCD display provides clear indication of flow rate and totalized flow, accessible through intuitive key selection.
Features
Full-bore ultrasonic flow meter for accurate liquid flow measurement
Transit Time sensing technology
Four-path chordal design for optimal linearity and repeatability
High accuracy: ±0.2% of measured value
Empty pipe indication and partial flow measurement
Negligible pressure drop
Optional pressure & temperature measurement
IoT-enabled device for smart monitoring
Wet calibration as per ISO 17025:2017
(NABL / ILAC Accredited Calibration Laboratory)
Suitable for clean conductive and non-conductive liquids
Description
ASIONIC 200 CF-B Battery Powered Clamp-On Ultrasonic Flow Meters are designed for accurate flow measurement of clean, sonically conductive liquids in industrial applications. Since the sensors are clamped externally on the pipe, the system eliminates any risk related to process compatibility commonly associated with in-line flow metering technologies.
The meter operates on the transit time measurement principle, where the instrument calculates fluid velocity by comparing the travel time of an ultrasonic signal moving with the flow versus a signal moving against the flow. By incorporating the sonic characteristics of the fluid and the pipe material, the system delivers highly repeatable and reliable volumetric flow measurements.
ASIONIC 200 CF-B is ideal for applications where easy installation, no process interruption, and zero pipeline modification are required. It is particularly suitable for large line sizes and installations where the use of exotic materials makes in-line metering uneconomical.
Features
Ultrasonic measurement using Transit Time Technology
Suitable for a wide range of pipe diameters
Easy installation — no need to cut the pipe or stop the flow
Portable or fixed installation options
External transducers require no periodic cleaning
Compact and lightweight design
No pressure drop or energy loss
Inbuilt data logging
Bi-directional flow measurement
Technical Specifications Performance Characteristics
Media: Sonically Conductive Liquids
Sensing Method: Differential Transit Time (Direct or Reflect Mode)
Viscosity: Up to 200 cP
Turbidity: < 10, 000 ppm with low air bubble content
Flow Velocity Range: –12 m/s to +12 m/s (40 ft/s)
Power Supply: 3.6V Rechargeable Battery
Accuracy*: < ±2% of F.S. + 5 mm/sec (for velocity range 0.3 m/s to 6 or 12 m/s)
Line Size: 50 NB to 100 NB, 125 NB to 300 NB
Acoustic Paths: Single Path
Display & Communication
Display: LCD
Communication:
RS-485 (MODBUS RTU)
Pulse (Open Collector)
GSM & GPRS
Data Logger: Internal Data Logging
Ambient & Operating Conditions
Ambient Temperature: –20°C to … / Humidity 5–95% (Non-Condensing)
Transducer Operating Temperature: –40°C to +80°C (Standard), –40°C to +150°C (Optional)
Transmitter Operating Temperature: –10°C to +60°C (14°F to 140°F)
Humidity: Up to 99% Relative Humidity (Non-Condensing)
Mechanical Details
Pipe Size: 50 NB (2”) to 300 NB (12”), Wall Thickness <10 mm
Pipe Material Compatibility: MS / SS / Cast Iron / Plastic
Transmitter Mounting: Pipe Mounted / Wall Mounted
Electronic Protection Class: Field Mount, Weatherproof IP-67
Sensor Cable: Encapsulated Design, Standard Length: 5 m
Sensor Mounting Method: “V” Method
Venturi Tube – Differential Pressure Flow Element Features
Venturi design as per BS EN ISO 5167
Construction options: Fabricated / Machined
Available in Bi-directional & Uni-directional designs
Flanged or Weld-in construction
Multiple Venturi Types:
Classical Venturi Tubes
Venturi Nozzles
Wide variety of material options
No moving parts – simple, robust construction
Maintenance-free design
Description
Electronet series Venturi Tube is the second most widely used differential pressure primary flow element.
It operates on proven Venturi flow measurement technology, contains no moving parts, and is suitable for high-temperature and high-pressure industrial applications.
Benefits of Venturi Tubes
Low permanent pressure loss compared to orifice plates and flow nozzles
High durability and long service life
Minimal risk of clogging from sludge or sediment
Ideal for applications requiring minimal pressure drop
Superior pressure recovery:
Unrecovered pressure typically 10–30% of measured DP
Compared to 40–90% for orifice plates (depending on beta ratio)
Venturi tubes are widely used in pipelines for liquid, gas, and steam flow measurement where efficiency, reliability, and energy savings are important.
Technical Specifications Line Size Ranges
Type A: 100–600 NB (4” – 24”)
Type B: 50–250 NB (2” – 10”)
Type C: 200–1200 NB (8” – 48”)
Construction Types
Type A: Cast Convergent Section
Type B: Machined Convergent Section
Type C: Rough Welded Sheet-Iron Convergent Section
Accuracy
Type A: ±0.7%
Type B: ±1.0%
Type C: ±1.5%
FL-600 PTC Flow Indicator Totaliser Product Description
The Electronet FL-600 PTC is a microcontroller-based Flow Indicator and Totaliser engineered for precise and compensated flow measurement in industrial applications.
It supports three separate inputsFlow, Temperature, and Pressureoffering fully compensated flow calculation. The unit provides LCD indication, programmable settings, low-flow cut-off, and software calibration for added flexibility.
A built-in battery backup ensures data retention in case of power failure, making it highly reliable for demanding process environments.
Key Features
Temperature & Pressure compensated flow measurement
Clear LCD display for real-time flow rate and totalised flow
Selectable input type: Linear / Square Root for flow
Normal operating mode
Input averaging for turbulent flow
Programmable low-flow cut-off
Software calibration
Suitable for industrial & field installations with rugged enclosure options
Technical Specifications Performance Characteristics
No. of Inputs: 03
Input Types
Flow Input:
420 mA / Voltage (05V / 15V)
Temperature Input:
420 mA or RTD
Pressure Input:
420 mA
Display
LCD display for Flow Rate and Totalised Flow
Range
Programmable: 0 to 9999
Accuracy
Better than 0.25% of Full Scale
Open Sensor Indication
Provided
Power Supply
90250 V AC, 50 Hz
24 V DC
Power Consumption
Less than 10 VA
Temperature Drift
Features
Full-bore type electromagnetic flow meter
Potential-free relay output for ON/OFF control
Suitable for conductive liquids
Empty pipe detection
Available in line sizes DN 15 to DN 300
High measurement accuracy of 0.5% of M.V.
Protection class: IP-68 (sensor + electronics)
Rugged SS-316 construction ensures long-term durability and corrosion resistance
Technical Specifications Performance Characteristics
Measuring Principle: Electromagnetic flow measurement
Media: Conductive liquids
Conductivity: > 5 S/cm
Viscosity: 200 cP
Line Size: 15 NB to 300 NB
Accuracy: 0.5% of M.V.
Excitation: Pulsed DC
Response Time: 1 sec
Display: Backlit LCD
6-digit flow rate
8-digit totalizer
Process Conditions
Process Temperature: up to 200C
Process Pressure: up to 16 kg/cm
Mounting Type: Inline Horizontal / Vertical
Process Connection: ANSI 150 flanged as per Table B 16.5 (others on request)
Ambient Conditions
Ambient Temperature: 20C to +75C
Humidity: 5% to 95% RH (non-condensing)
Output Signals
Output 1: 420 mA
Output 2: Pulse (Open Collector Type) Optional
Alarm/Relay Output: 1 potential-free relay Optional
Communication: RS-485 MODBUS RTU Optional
Protection
Electronics Protection: Weatherproof IP-68
Sensor / Flow Tube Protection: Weatherproof IP-68
Electronics Location: Integral or remote
Remote Cable Length: 5 meters
Electrical Connection: M12 connector
Power Requirements
Voltage Supply: 1830 V DC
Power Consumption: < 5 VA
Material of Construction
Lining Options: Neoprene, Ebonite Rubber, PFA, PTFE, PU, Ceramic
Flange Material: MS, CS, SS-316, SS-304
Coil Housing: SS-316L
Electrodes: SS-316L / Hastelloy C / Platinum / Tantalum / Titanium
Electronics Enclosure: SS-316
Features
Ultrasonic measurement using Transit Time technology
2-wire system with HART communication
Full-bore type design
Suitable for conductive and non-conductive liquids
Material options available based on process requirements
Local LCD display for indication
Empty pipe detection
Electronic protection: Field-mount Weatherproof IP-67 & Flameproof (CMRI IIA IIB Certified)
Maintenance-free operation
Options for integral and hot-retractable sensor assembly
Description
Electronet series ASIONIC™ 100 are microcontroller-based, 2-wire, full-bore ultrasonic flow transmitters designed for a wide range of industrial applications. These transmitters accurately measure the flow rate of conductive and non-conductive liquids in closed piping systems.
With a simple and robust construction, the instrument ensures obstruction-less flow measurement and requires no mechanical maintenance, making it a reliable alternative to conventional flowmeters. The use of advanced Transit Time Technology ensures superior accuracy, generating a linear 4–20 mA DC output proportional to volumetric flow.
Technical Specifications General
Media: Liquids
Line Size: 15 NB to 600 NB (with sensor spool piece)
Electronics Version:
Integral (Local)
Remote
Viscosity: Up to 200 cp
Display: LCD — 5-digit flow rate, 8-digit totalized flow
Calibration Range: As per requirement (factory calibrated for standard 2 m/s velocity)
Performance
Accuracy: ±0.5% of M.V. + 5 mm/sec
(Velocity range: 0.3 m/s to 6 or 12 m/s)
Linearity: ±0.5% of M.V.
Repeatability: ±0.2% of M.V.
Temperature Coefficient: ±0.05% per °C
Response Time: <10 seconds
Process Conditions
Process Pressure: Up to 10 kg/cm²
Process Connections: ANSI 150 flanged (as per table B 16.5)
(Other options available on request)
Mounting: Inline — Horizontal / Vertical
Material of Construction
Flange: MS / CS / SS304 / SS316 / PVC
Sensor: SS316
Electrical Specifications
Power Supply:
24V DC
24V DC — Two-wire loop powered
Power Consumption: <40 mW
Output: 4–20 mA / 4–20 mA with HART (Generic)
Environmental Conditions
Ambient Temperature: –20°C to +60°C
Ambient Humidity: 5–95% RH (non-condensing)
Electronic Protection:
Field-mount Weatherproof IP-67 (DIN Standard IP-54)
Flameproof (CMRI IIA IIB Certified)
Certification: CE
ELMAG-100 Insertion Type Electromagnetic Flow Meter Features
Insertion type design
Suitable for conductive liquids
Material of construction selected as per process requirements
Local indication through LCD display
Universal power supply: 90 to 250V AC (Optional: 24V DC)
Simple and cost-effective construction
Programmable engineering unit conversion
Communication port available
Inbuilt relay status output (High / Low / Batch)
Description
Electronet Series ELMAG-100 is a microcontroller-based insertion type Electromagnetic Flow Meter designed for accurate flow measurement of conductive liquids and slurries in closed pipelines.
The flow meter features an obstruction-free measuring design, making it maintenance-free compared to conventional mechanical meters.
Using advanced Pulsed DC excitation, the flow meter ensures highly stable and accurate flow measurement and provides a 420 mA DC electrical output linearly proportional to volumetric flow rate.
Based on Faradays Law of Electromagnetic Induction, the meter generates a magnetic field inside the flow tube. The conductive fluid passing through it induces a voltage proportional to the flow velocity, which is then converted into a corresponding electrical signal.
The ELMAG-100 is available in Hot Retractable and Fixed Insertion versions to suit a wide range of industrial applications.
Technical Specifications Model Types
Mains Operated / 24V DC
Two-Wire Version
Battery Operated
Media
Conductive liquids
Conductivity: > 5 S/cm
Viscosity: Up to 200 cP
Line Size
200 NB to 3000 NB
Excitation
Pulsed DC
Display
LCD Display
6-digit flow rate
8-digit totalizer
4-digit pressure
Calibration Range
As per application requirement
Accuracy
< 1% of E.S.
Additional: 5 mm/sec for velocity range 0.5 m/s to 6 or 12 m/s
Linearity
1% of F.S.
Repeatability
0.5% of F.S.
Temperature Coefficient
0.05% per C
Description
Electronet Series ASIONIC®-400 Ultrasonic Flow Meters provide the flexibility to install a reliable flow measurement system virtually anywhere without compromising accuracy or performance. These flow meters are extremely easy to use, simple to install, and require no regular maintenance.
They are designed for a wide range of industrial and domestic applications, including municipal water systems, industrial water distribution, cooling towers, and water treatment processes.
The LCD display provides a clear indication of flow rate and totalized flow, accessible through key selection. In battery-powered models, the display automatically shuts off after 10 minutes to extend battery life and can be turned on again by pressing the “Enter” key.
Features
Ultrasonic measurement using Transit Time Technology
Full-bore type construction
Local indication through LCD display
Simple and cost-effective design
Empty pipe indication
Automatic Meter Reading (AMR) via GSM, GPRS & RF
Electronic Protection:
Field Mount Weatherproof IP-67
DIN Standard (IP-54)
Flameproof (CMRI IIA IIB Certified)
Leak, burst, and tamper detection
No pressure drop
Technical Specifications Performance Characteristics
Media: Liquids
Line Size: 15 NB to 600 NB
Number of Paths: Single
Electronics:
Integral (Local)
Remote
Output:
4–20 mA DC
Pulse (Open Collector)
Frequency (0 to 1 kHz)
Communication: RS-485 (MODBUS RTU), GSM, GPRS, RF
Viscosity: Up to 200 cP
Display: LCD — 7-digit Flow Rate & 8-digit Totalized Flow
Calibration Range: Factory Calibrated (as per requirement)
Accuracy: < ±0.5% of M.V. + 5 mm/sec (Velocity 0.3 m/s to 6 or 12 m/s)
Linearity: ±0.5% of M.V.
Repeatability: ±0.2% of M.V.
Temperature Coefficient: ±0.05% per °C
Process Conditions
Process Temperature: –20°C to 85°C max
Process Pressure: 16 kg/cm² max
Material of Construction: Flow Tube — SS304, SS316, PVC, MS
Power & Operation
Power Supply: 24V DC (±10%), Solar Powered (Optional)
Low Battery Indication: Provided
Battery Life: 5 to 10 years (depending on sampling/communication interval)
Response Time: < 10 seconds
Mechanical & Environmental
Electronic Protection:
Field Mount IP-67
DIN Standard IP-54
Flameproof (CMRI IIA IIB Certified)
Process Connection: ASA 150 Flanged (as per Table B 16.5)
Ambient Conditions: –20°C to 70°C / 5–95% RH (Non-Condensing)
Data Logging: 5-year capability (1 sample per day)
Certification: CE
FL-244 OC Flow Indicator & Totaliser Product Description
The Electronet FL-244 OC is a microcontroller-based flow indicator and totaliser designed for industrial flow measurement applications. It supports linear, multipoint, and square-root inputs, making it highly flexible for various process conditions.
With advanced features like batch mode operation, low-flow cut-off, input averaging, and MODBUS RTU communication, this indicator provides reliable and accurate flow monitoring for pipelines, process plants, and utility systems.
Key Features
LED indication for process status
Selectable input type: Linear / Multipoint Table
Normal & Batch operating modes
Input averaging for turbulent flow conditions
Programmable low-flow cut-off
Software calibration for easy setup
MODBUS RTU communication support
High-accuracy measurement
Rugged industrial enclosure options (DIN, Weatherproof, Flameproof)
Technical Specifications Performance
Operating Modes: Normal / Batch
Input Options
Voltage: 1–5 V (Linear)
Current: 4–20 mA (Linear)
Frequency: 0–10 kHz
Display
LCD display for flow rate and totalised flow
Range
Programmable: 0 to 9999
Accuracy
Better than ±0.25% of Full Scale
Open Sensor Indication
Available
Power Supply
90–250 V AC
Power Consumption
<10 VA
Temperature Drift
<0.01% of F.S./°C
Response Time
<200 mSec
Electrical Isolation
1.4 KV between input, output & power supply
Mechanical Specifications Enclosure Types
DIN Standard
Weatherproof IP65
Flameproof (CMRI IIA IIB Certified)
Dimensions
96 (H) × 96 (W) × 160 (D) mm (DIN Standard)
Mounting
Panel flush mounting (DIN)
Wall mounting (Weatherproof)
Weight
Less than 2 kg
Operating Environment
Temperature: –20°C to 55°C
Humidity: 5% to 95% non-condensing
Optional Features Transmitter Power Supply
24V DC, 100 mA
Retransmission Output
4–20 mA
Alarm Outputs
2 potential-free relay contacts
1 C/O, 1A @ 230V AC
Configurable for High, Low, and Batch operations
Communication Port
RS485 with MODBUS RTU protocol
Description
Electronet series ASIONIC™ 200 is a microcontroller-based, full-bore Ultrasonic Flow Meter designed for accurate measurement of liquid flow in closed pipes. Its rigid and obstruction-less design makes it a maintenance-free alternative to traditional mechanical flow meters.
The system is engineered for dependable performance across diverse industrial environments. User-friendly programming through four front-panel keys provides easy access to extensive diagnostic data. Electronet offers multiple flow meter consoles to meet specific application needs.
Features
Ultrasonic measurement using Transit Time Technology
EMI/EMC compliant
Single / Dual / Quad beam technology for high-precision measurement
Excellent long-term stability and reliability
Inline and hot-retractable sensor assembly
Empty pipe detection
No pressure drop
Electronic Protection Class:
Field-mount Weatherproof IP-67
DIN Standard (IP-54)
Flameproof (CMRI IIA IIB Certified)
Technical Specifications Performance Characteristics
Media: Sonically conductive liquids
Line Size: 15 NB to 1000 NB
Electronics:
Integral (Local)
Remote
Viscosity: Up to 200 cP
Turbidity: <10, 000 ppm (mg/L) with low air bubble content
Display: LCD — 6-digit flow rate & 8-digit totalized flow
Calibration Range: Factory calibrated as required
Acoustic Paths: Single, Dual & Four Path
Additional Performance
Linearity: ±0.5% of M.V.
Repeatability: ±0.2% of M.V.
Temperature Coefficient: ±0.05% per °C
Response Time: <1 sec
Process Conditions
Process Temperature: –20°C to 85°C
Process Pressure: Up to 16 kg/cm²
Process Connections: ANSI 150 flanged (as per table B 16.5)
Sensor Pair: As per requirement
Sensor MOC: SS316
Material of Construction
Flow Tube: SS304 / SS316 / PVC / MS
Electrical Specifications
Power Supply:
90–250V AC, 50 Hz
24V DC (±10%)
Communication Output:
RS-485 (MODBUS RTU)
GSM / GPRS
Output:
4–20 mA
4–20 mA with HART (Generic)
Environmental Conditions
Ambient Temperature: –20°C to 75°C
Humidity: 5–95% RH (non-condensing)
Electronic Protection:
Field-mount Weatherproof IP-67
DIN Standard IP-54
Flameproof (CMRI IIA IIB Certified)
Certification: CE
ASIONIC™ 200C Clamp-On Ultrasonic Flow Meters accurately measure liquid flow rates in industrial applications without any pipe cutting or process interruption. Since sensors are clamped externally onto the pipe, the system eliminates contamination, pressure drop, maintenance issues, and material compatibility concerns associated with inline flow meters.
The meter uses Transit Time Technology, comparing the travel time of ultrasonic signals moving with and against the flow. This enables accurate and repeatable measurement of fluid velocity and volumetric flow rate while accounting for sonic properties of the pipe and fluid.
ASIONIC™ 200C supports one or two transducer inputs, allowing comparison between two flow streams. It is ideal for applications requiring non-intrusive installation, measurement on large-diameter pipes, or pipelines made from special materials where inline meters are impractical.
Features
Ultrasonic measurement using Transit Time Technology
Easy installation — no need to cut pipe or stop flow
External transducers require no periodic cleaning
No pressure drop or energy loss
Bi-directional flow measurement
Suitable for a wide range of pipe diameters
Portable or fixed installation options
Compact and lightweight design
Inbuilt data logging
Pipe Line Size: 50 NB to 2000 NB
Sensing Method: Differential transit-time (direct or reflect mode)
Media: Sonically conductive liquids
Viscosity: Up to 200 cP
Turbidity: <10, 000 ppm with low air bubble content
Accuracy: ±2% of F.S. + 5 mm/sec (Velocity range: 0.3 m/s to 6 or 12 m/s)
Acoustic Paths: Single
Display: LCD
Power Supply Options:
90–250V AC
24V DC (±10%)
Solar powered 24V DC
Communication Interface: RS-485 MODBUS RTU
Data Logging: Internal, inbuilt
Ambient Temperature: –20°C to +75°C
Ambient Humidity: 5–95% RH (non-condensing)
Operating Temperature:
Standard: –20°C to 80°C
Optional: –20°C to 150°C
Pipe Size Compatibility: 50 mm (2") to 2000 mm (80")
Pipe Wall Thickness: <20 mm
Pipe Material Compatibility: MS / SS / Cast Iron / Plastic
Sensor Cable: Encapsulated design
Standard length: 9 m
Optional: up to 15 m
Sensor Mounting Methods:
“V” method
“Z” method
Sensor Types:
Small (50 NB–100 NB)
Medium (125 NB–300 NB)
Large (350 NB–2000 NB)
Analog Output: Isolated 4–20 mA, 600 Ω load
Communication: RS-485 MODBUS RTU
Electronics Enclosure: Cast Aluminium / ABS Plastic / SS316
Transmitter Mounting: Wall-mounted
Electronic Protection:
Field-mount Weatherproof IP-67
DIN Standard IP-54
CE Certified
Product Description
The Electronet FL-244 is a microcontroller-based flow indicator and totaliser designed for accurate flow measurement in industrial applications.
It supports linear and square-root inputs, making it suitable for differential pressure flowmeters, orifice/venturi systems, and other flow metering instruments.
Equipped with batch mode, low-flow cut-off, input averaging, and MODBUS RTU communication, the FL-244 ensures reliable flow monitoring with flexible configuration options.
Key Features
LED display with clear flow indication
Selectable input type: Linear / Square Root
Supports Normal & Batch operating modes
Input averaging for turbulent flow conditions
Programmable low-flow cut-off
Software calibration for easy configuration
MODBUS RTU communication
Suitable for industrial environments with multiple enclosure options
Technical Specifications Performance Characteristics
Operating Modes: Normal / Batch
Input Types
Voltage: 1–5 V (Linear / Square Root)
Current: 4–20 mA (Linear / Square Root)
Frequency: 0–10 kHz
Display
LED display for flow rate and totalised flow
Range
Programmable from 0 to 9999
Accuracy
Better than ±0.25% of Full Scale
Open Sensor Indication
Available
Power Supply
90–250 V AC
Power Consumption
Less than 10 VA
Temperature Drift
<0.01% of F.S. / °C
Response Time
<200 mSec
Electrical Isolation
1.4 KV isolation between input, output & power supply
Enclosure & Mechanical Details Enclosure Options
DIN Standard
Weatherproof (IP65)
Flameproof (CMRI IIA IIB Certified)
Dimensions
96 mm (H) × 96 mm (W) × 160 mm (D)
Mounting
Panel flush mounting (DIN)
Wall mounting (Weatherproof enclosure)
Weight
Less than 2 kg
Ambient Conditions
Temperature: –20°C to 55°C
Humidity: 5% to 95% non-condensing
ELMAG-200 Full Bore Electromagnetic Flow Meter Features
Universal power supply: 90250V AC / 24V DC / Solar Powered
Suitable for conductive liquids
Full-bore design
Empty pipe indication
Material of construction selected as per process requirements
Local indication through LCD display
Inbuilt relay status output (High / Low / Batch)
HART compatible
Optional inbuilt pressure measurement
Optional flow + pressure combined measurement
Description
Electronet Series ELMAG-200 is a microcontroller-based, full-bore electromagnetic flow meter ideal for precise flow measurement of conductive liquids and slurries in closed pipes.
Its obstruction-less design and absence of moving parts make it a maintenance-free alternative to conventional mechanical meters.
Using advanced Pulsed DC excitation, the meter provides superior accuracy and stability, delivering a 420 mA DC output proportional to volumetric flow rate.
Based on Faradays Law of Electromagnetic Induction, the flow meter measures flow by detecting the voltage generated when conductive fluid passes through a magnetic field inside the measuring tube.
The ELMAG-200 is available in various configurations to suit diverse industrial requirements including optional pressure measurement.
Technical Specifications Process & Media
Media: Conductive liquid
Minimum Conductivity: > 5 S/cm
Viscosity: Up to 200 cP
Line Size: 15 NB to 1000 NB
Excitation: Pulsed DC
Outputs (Selectable)
Output 1:
420 mA DC
420 mA DC with HART (Generic)
Output 2:
Pulse Output (Open Collector Type)
Output 3:
2 Relay Outputs
Communication Options:
RS485 (MODBUS RTU)
GSM / GPRS (Dual SIM)
Ethernet (MODBUS TCP)
Display
LCD Display
6-digit flow rate
8-digit totalizer
Performance Specifications Velocity
0.3 m/s 2.5 m/s (up to maximum 10 m/s)
Engineering Units
User programmable (Default: m/hr)
Calibration
Wet calibrated at IEC / ISO / EN17025 NABL Accredited Facility
Accuracy
< 0.5% of Measured Value
(+5 mm/sec for velocity range 0.3 to 6 or 12 m/s)
Linearity
0.5% of Measured Value
Repeatability
0.2% of Measured Value
Temperature Coefficient
0.05% per C
Process Conditions Process Temperature
20 to 85C (Rubber Lining)
20 to 220C (PTFE / PFA Lining)
Process Pressure
Up to 16 kg/cm (Higher on request)
Material of Construction
Lining: Neoprene / Ebonite Rubber / PTFE / PFA / PU / Ceramic
Flange: MS / CS / SS316 / SS304
Electrodes: SS316L / Hastelloy-C / Platinum / Tantalum / Titanium
Coil Housing: SS304
Electrical & Electronics Power Supply
Option 1: 90250V AC, 50Hz
Option 2: 24V DC (10%)
Power Consumption
< 10 VA
Inline Pressure Sensor (Optional)
16 kg/cm
Isolation
1.4 kV between input, output & power supply
Response Time
< 1 second
Enclosure Options
Field Mount Weatherproof IP-67 / IP-68 (NEMA 6 / 6P)
DIN Standard IP-54 (NEMA 3)
Flameproof: CMRI IIA IIB Certified, ATEX Ex-d
Sensor / Flow Tube Protection
Weatherproof IP-67 / IP-68
Installation Process Connections
ANSI 150 Flanged (ASME B16.5)
Other standards on request
Mounting
In-line horizontal or vertical installation
Ambient Conditions
Temperature: 20 to 70C
Humidity: 5% to 95% (Non-condensing)
ELMAG-TX22 Two-Wire Full Bore Electromagnetic Flow Transmitter Features
Full-bore electromagnetic design
Suitable for conductive liquids
Two-wire transmitter system
Empty pipe indication
Material options available as per process requirements
Local LCD display for flow rate & totalizer
Maintenance-free, obstruction-less design
Simple and cost-effective construction
Description
The Electronet ELMAG-TX22 is a microcontroller-based, two-wire, full-bore electromagnetic flow transmitter designed for accurate measurement of conductive liquids and slurries in closed pipelines.
Built using Pulsed DC excitation technology, the ELMAG-TX22 provides high stability, excellent accuracy, and long-term reliability. The device generates a magnetic field inside the flow tubebased on Faradays Law of Electromagnetic Inductionand the voltage induced by the flowing liquid is converted into a precise 420 mA output (with optional HART).
Its obstruction-free design ensures zero pressure loss, minimal maintenance, and long operational life. The rugged construction, multiple material options, and advanced signal processing make it suitable for a wide range of industrial applications.
Technical Specifications Process & Media
Media: Conductive liquids
Line Size: 15 NB to 300 NB
Conductivity: > 5 S/cm
Viscosity: up to 200 cP
Electronics
Type: Integral
Power Supply: 24 V DC
Power Consumption: 40 mW
Excitation: Pulsed DC coil
Display:
LCD
5-digit flow rate
8-digit totalizer
Output Options:
420 mA DC
420 mA DC with HART
Performance
Accuracy: < 0.5% of M.V. (+5 mm/s for velocity range 0.36 or 12 m/s)
Flow Velocity Range: 0.3 m/s to 6 m/s
Extended Velocity Range: up to 10 m/s
Linearity: 0.5% of M.V.
Repeatability: 0.2% of M.V.
Temperature Coefficient: 0.1% per C
Temperature & Pressure
Process Temperature:
20 to 85C (Rubber lining)
20 to 220C (PTFE lining)
Process Pressure: up to 16 kg/cm (higher on request)
Material of Construction
Lining: Neoprene / Ebonite Rubber / PTFE / PFA / PU / Ceramic
Flange: MS / CS / SS316 / SS304 / PVC
Electrodes: SS316L / Hastelloy-C / Platinum / Tantalum / Titanium
Coil Housing: MS / SS304 / SS316 / PVC
Electrical & Safety
Isolation: 1.4 kV between input, output & power supply
Response Time: < 10 seconds
Electronic Protection Class:
IP-67 / IP-68 (Field mount)
Sensor/Flow Tube Protection: IP-68
Installation
Process Connection: ANSI 150 flanged (ASME B16.5) others on request
Mounting: In-line (horizontal or vertical)
Ambient Temperature: 20C to +70C
Ambient Humidity: 5% to 95% RH (non-condensing)
Remote Display Option Available
Simple & Cost-Effective Construction
LCD Display for Flow Rate & Total Flow
Suitable for Conductive and Non-Conductive Liquids
Long Battery Life (2 to 10 Years)
Durable & Versatile
Maintenance-Free Operation
Electronics Protection:
Weatherproof IP67
Flameproof (CMRI IIA & IIB Certified)
Electronet series FL-106 are battery-operated turbine flow transmitters designed for industrial liquid flow measurement.
The flowing media rotates a vaned rotor at an angular velocity proportional to the flow rate. The pick-up coil senses this rotation and converts it into a pulsating electrical signal.
The summation of these pulses corresponds to the total flow, and the pulse frequency is proportional to the instantaneous flow rate.
The device features a long-life battery, LCD display, and optional remote electronics for flexible installation.
Media: Clear Liquids
Line Size: 15 NB to 200 NB
Electronics: Integral (Local) / Remote
Viscosity: Up to 100 cP
Calibration Range: Factory Calibrated (As per requirement)
Accuracy: ±0.5% of Reading + 5 mm/sec (Velocity range: 0.3 m/s to 6 or 12 m/s)
Linearity: < ±0.25% of Reading
Repeatability: ±0.25% of Reading
Turn Down Ratio: 10:1
Pressure Drop: Approx. 0.28 kg/cm² @ maximum flow
Process Pressure: 0 to 10 kg/cm²
Process Temperature: -20°C to 120°C
LCD Display
4-digit Flow Rate
8-digit Totalized Flow
Toggle key for switching between Flow Rate & Total Flow
Power Supply: Battery Operated (2 × 3.6V DC)
Battery Life: 2–10 Years (Depends on sampling time)
Power Consumption: < 40 mW
Response Time: < 500 mSec
Remote Electronics Cable: Up to 15 meters
Protection Class:
Weatherproof IP67
Flameproof CMRI IIA/IIB Certified
Bearings: Tungsten Carbide Sleeve / V-Jewel
Rotor: SS410 / 17-4 PH
Shaft: Tungsten Carbide
Body / Support / Flange: Stainless Steel
Flanged: ASA 150 RF (Up to 200 NB)
Threaded: Up to 50 NB
Tri-Clover: Up to 100 NB
SMS Union: 25 to 100 NB
In-Line Installation (Horizontal or Vertical)
Temperature: -20°C to 120°C
Humidity: 5% to 95% RH (Non-Condensing)
BTU 200 BTU Metering System
(Clamp-On / Insertion Ultrasonic Flow Meter Based)
Features
Highly accurate and reliable metering system
Flow meters calibrated at in-houseNABL Accredited Flow Calibration Facility
Precise temperature measurement using high-performance temperature sensors
Network-compatible communication protocols
Multiple engineering units available for displaying measured parameters
User-friendly interface with display and keypad
Simple installation and commissioning
Data storage and log view facility
Description
Electronet SeriesBTU 200is a high-precision BTU metering system designed for measuringthermal energy flowandenergy consumptionin water-based systems.
It is ideal for industrial, commercial, and domestic applications, offering accurate flow measurement using eitherClamp-On Ultrasonic Flow MeterorInsertion Type Ultrasonic Flow Meter.
The system includes:
Ultrasonic Flow Meter (Clamp-On / Insertion)
Pair of PT-100 Temperature Sensors (inlet & outlet)
BTU Calculator / Indicator with LCD Display
BTU 200 is a reliable choice for measurement and indication offluid flowandnet thermal energy consumption.
Applications
Suitable for Chilled & Hot Water Systems in:
Industrial water systems
Domestic & commercial complexes
Office buildings
Central plant monitoring
Institutional energy cost allocation
Educational campus monitoring
Water management systems
Technical SpecificationsPerformance CharacteristicsPower
Power Supply:90270V AC / 24V DC
Units
Power Unit:BTU/hr or kW
Energy Unit:BTU or kW/hr
Display
Type:LCD display
Accuracy
Overall Accuracy:0.1% of measured value
Inputs
Flow Meter Input:420 mA DC
Temperature Input:Set of two PT-100 sensors
End Connection Options
DIN
ANSI 150
BS Standard
Threaded
Outputs
Analog Output:420 mA DC
Digital Output:2 Nos. Potential-free relay (1 C/O), 1 Amp @ 230V
Communication Interface:RS-485
Energy Functions
Heat / Cool
Selectable display units: W, BTU, Cal, J
Sampling Period
1 second
Environmental Conditions
Ambient Temperature:Up to 65C
Water Temperature:0 to 180C
Enclosure:IP-65 protection class
Mechanical
Dimensions:155 mm (H) 155 mm (W) 126 mm (D)
Orifice Plate – Differential Pressure Flow Element Features
Orifice design as per BS EN ISO 5167
Available Orifice Types:
Concentric Square Edge
Quarter Circle
Segmental
Eccentric
Wide range of material options
No moving parts – simple, robust design
Suitable for Liquid, Gas & Vapor applications
Maintenance-free
Ideal for high temperature and high pressure conditions
Description
Electronet series Orifice Plate is one of the most widely used differential pressure primary flow elements.
It operates on proven flow measurement principles, contains no moving parts, and is suitable for high-temperature and high-pressure applications.
These orifice plates are recommended for:
Clean liquids
Gases
Low-velocity steam
Accurate flow measurement using orifice plates requires correct positioning of upstream and downstream pressure tapping points.
A variety of orifice carrier assemblies are available to suit a wide range of industrial applications.
Technical Specifications General
Line Size: 15 NB to 1000 NB (½” to 40”)
Accuracy: ±1% of F.S.
Orifice Types
Concentric Square Edge
Quarter Circle
Conical Entrance
Segmental
Eccentric
Material Options
AISI 316
AISI 304
Hastelloy C
Monel
Ultrasonic measurement using Transit Time Technology
Full-bore construction
Empty pipe indication
Backlit LCD display
Durable SS-316 enclosure for superior corrosion resistance
IP-68 protection for reliable operation in harsh and wet environments
Measuring Principle: Ultrasonic flow measurement
Media: Liquids
Line Size: 15 NB to 300 NB
Number of Paths: Single
Electronics: Integral (Local) / Remote
Remote Cable Length: 5 meters
Output 1: 4–20 mA
Output 2: Pulse – Open Collector (Optional)
Alarm / Relay Output: 1 Relay Output (Optional)
Communication Output: RS-485 (MODBUS RTU) (Optional)
Display: Backlit LCD (6-digit Flow Rate, 8-digit Totalizer)
Accuracy: < ±0.5% of M.V. (Velocity range: 0.3 m/s to 6 or 12 m/s)
Linearity: ±0.5% of M.V.
Repeatability: ±0.2% of M.V.
Temperature Coefficient: ±0.05% per °C
Process Temperature: Up to 200°C
Process Pressure: Up to 16 kg/cm²
Process Connections: ASA 150 Flanged (As per table)
Flow Tube: SS-316
Electronics Enclosure: SS-316
Sensor: SS-316 / PVC
Power Supply: 24V DC
Response Time: 1 second
Electrical Connection: M12 Connector
Electronic Protection: Weatherproof IP-68
Sensor / Flow Tube Protection: Weatherproof IP-68
Ambient Temperature: –20°C to 75°C
Humidity: 5% to 95% (Non-condensing)
The Electronet FL-204 is a robust four-wire turbine flow transmitter designed for precise flow measurement in a wide range of industrial applications. Its simple, cost-effective construction and high-performance magnetic sensing technology make it ideal for both conductive and non-conductive liquids. With an LED display, flexible output options, and IP-67 / Flameproof protection, the FL-204 ensures reliable operation even in harsh environments.
Key Features4-wire system for stable and accurate signal transmission
Simple and cost-effective construction
Suitable for conductive and non-conductive liquids
Bright LED display for flow rate (4 digits) and totalized flow (8 digits)
Batch / High / Low relay output options
Integral or remote electronics configuration
Low maintenance with durable construction
Weatherproof IP-67 & Flameproof (CMRI IIA IIB) certified electronics
The flowing liquid rotates a vaned rotor inside the pipe. A magnetic pickup coil senses the rotor's angular velocity and converts it into a pulsating electrical signal.
The signal frequency is directly proportional to the flow rate.
The transmitter converts this into a linear 4–20 mA output for process control.
Total flow is obtained by summing the pulse signals.
Media: Liquids
Line Size: 15 NB to 200 NB
Electronics: Integral or Remote
Viscosity: Up to 100 cP
Display: LED – 4-digit flow rate & 8-digit totalizer
Pick-off Type: Magnetic sensor
Remote Cable Length: Up to 15 meters
Outputs:
4–20 mA DC
Pulse (Open Collector)
Calibration Range: Factory calibrated as per requirement
Accuracy: ±0.5% of F.S. + 5 mm/sec (velocity 0.3–6/12 m/s)
Linearity: ±0.5% of F.S.
Repeatability: ±0.5% of F.S.
Temperature Coefficient: ±0.01% / °C
Pressure Drop: Approx. 0.28 kg/cm² at maximum flow
Turndown Ratio: 10:1
Process Temperature: –20 to 120°C
Process Pressure: 0 to 10 kg/cm²
Bearings: Tungsten Carbide Sleeve / V-Jewel
Rotor: SS 410 / 17.4 PH
Shaft: Tungsten Carbide
Body / Support / Flange: Stainless Steel
Power Supply: 24 V DC (±10%)
Power Consumption: <1 VA
Electrical Connections:
M20 x 1.5F
1/2" NPT-F
Pluggable Connector
Response Time: <100 ms
Protection: IP-67 Weatherproof & Flameproof (CMRI IIA IIB Certified)
Process Connections:
ASA 150 RF Flanged (15–200 NB)
Threaded (15–50 NB)
SS Tri-Clover (15–100 NB)
SMS Union (25–100 NB)
Mounting: In-line (Horizontal or Vertical)
Ambient Conditions: –20 to 120°C; 5–95% RH (non-condensing)
Relay Outputs: 1 or 2 relays (max 2 alarms)
Certification: CE
Simple & Cost-Effective Construction
Provides Wide Flow Ranges
Suitable for Non-Conductive, Clear Liquids
Optional Remote Display Available
Easy Maintenance
Electronics Protection:
Weatherproof IP65
Flameproof (CMRI IIA/IIB Certified)
Electronet’s FL-102 turbine flow transmitters are designed for accurate flow measurement in industrial applications.
The flowing media rotates a vaned rotor at a speed proportional to the flow rate. A pick-up coil senses the rotor motion and generates a pulsating electrical signal.
The frequency of this signal is directly proportional to the flow rate and is converted into a standard 4–20 mA or Pulse (Open Collector) output. Summation of these pulses represents the total flow.
Technical Specifications Performance CharacteristicsMedia: Clear Liquids
Line Size: 15 NB to 200 NB
Viscosity: Up to 100 cP
Outputs:
4–20 mA DC
Pulse (Open Collector)
Calibration Range: Factory Calibrated (As per requirement)
Accuracy: < ±0.5% of F.S. (20–100% Flow Range)
Linearity: ±1% of F.S.
Repeatability: ±1% of F.S.
Pressure Drop: Approx. 0.28 kg/cm² @ max flow
Turn Down Ratio: 10:1 to 100:1
Process Temperature: 0°C to 85°C (max)
Process Pressure: 0 to 10 kg/cm²
Temperature Coefficient: ±0.01% per °C
Bearings: Tungsten Carbide Sleeve / V-Jewel
Rotor: SS410 / 17-4 PH
Shaft: Tungsten Carbide
Body / Support / Flange: Stainless Steel
Power Supply: 24V DC
Power Consumption: < 1 VA
Response Time: < 100 mSec
M20 × 1.5 (F)
½" NPT (F)
Pluggable Connector
Threaded: 15 NB to 50 NB
Flanged: 15 NB to 200 NB
Tri-Clover: 15 NB to 100 NB
SMS Union: 25 NB to 100 NB
In-Line Installation (Horizontal or Vertical)
Temperature: 0°C to 55°C
Humidity: 5% to 95% RH (Non-Condensing)
BTU 200 BTU Metering System
(Clamp-On / Insertion Ultrasonic Flow Meter Based)
Features
Highly accurate and reliable metering system
Flow meters calibrated at in-house NABL Accredited Flow Calibration Facility
Precise temperature measurement using high-performance temperature sensors
Network-compatible communication protocols
Multiple engineering units available for displaying measured parameters
User-friendly interface with display and keypad
Simple installation and commissioning
Data storage and log view facility
Description
Electronet Series BTU 200 is a high-precision BTU metering system designed for measuring thermal energy flow and energy consumption in water-based systems.
It is ideal for industrial, commercial, and domestic applications, offering accurate flow measurement using either Clamp-On Ultrasonic Flow Meter or Insertion Type Ultrasonic Flow Meter.
The system includes:
Ultrasonic Flow Meter (Clamp-On / Insertion)
Pair of PT-100 Temperature Sensors (inlet & outlet)
BTU Calculator / Indicator with LCD Display
BTU 200 is a reliable choice for measurement and indication of fluid flow and net thermal energy consumption.
Applications
Suitable for Chilled & Hot Water Systems in:
Industrial water systems
Domestic & commercial complexes
Office buildings
Central plant monitoring
Institutional energy cost allocation
Educational campus monitoring
Water management systems
Technical Specifications Performance Characteristics Power
Power Supply: 90270V AC / 24V DC
Units
Power Unit: BTU/hr or kW
Energy Unit: BTU or kW/hr
Display
Type: LCD display
Accuracy
Overall Accuracy: 0.1% of measured value
Inputs
Flow Meter Input: 420 mA DC
Temperature Input: Set of two PT-100 sensors
End Connection Options
DIN
ANSI 150
BS Standard
Threaded
Outputs
Analog Output: 420 mA DC
Digital Output: 2 Nos. Potential-free relay (1 C/O), 1 Amp @ 230V
Communication Interface: RS-485
Energy Functions
Heat / Cool
Selectable display units: W, BTU, Cal, J
Sampling Period
1 second
Environmental Conditions
Ambient Temperature: Up to 65C
Water Temperature: 0 to 180C
Enclosure: IP-65 protection class
Mechanical
Mounting: Panel or Pipe
Dimensions: 155 mm (H) 155 mm (W) 126 mm (D)
Backlit LCD display
Suitable for conductive and non-conductive liquids
SS-316 enclosure with high corrosion resistance
IP-68 protection for harsh environments
RS-485 (MODBUS RTU) communication
Measuring Principle: Turbine flow measurement
Media: Liquid
Viscosity: Up to 100 cp
Line Size: 15 NB to 200 NB
Mounting Type: Inline (Horizontal / Vertical)
Linearity: ±0.5% of F.S
Repeatability: ±0.5% of F.S
Response Time: 1 sec
Accuracy: ±0.5% of F.S + 5 mm/sec (Velocity range: 0.3 m/s to 6 or 12 m/s)
Display: Backlit LCD — 6-digit flow rate & 8-digit totalizer
Process Temperature: Up to 200°C
Process Pressure: Up to 16 kg/cm²
Process Connection:
Flanged (15 to 200 NB)
Threaded (15 to 50 NB)
SS Tri-Clover (15 to 100 NB)
SMS Union (25 to 100 NB)
Power Supply: 24V DC
Power Consumption: <5W
Output 1: 4–20 mA
Output 2: Pulse (Open Collector – Optional)
Alarm/Relay Output: 1 Relay (Optional)
Communication: RS-485 MODBUS RTU (Optional)
Electronic Protection: Weatherproof IP-68
Electronics Location: Integral / Remote
Remote Cable Length: 5 meters
Flow Tube Protection: Weatherproof IP-68
Connector: M12
Bearings: Tungsten Carbide Sleeve / V-Jewel
Rotor: SS 410 / 17.4 PH / Plastoferrite
Shaft: Tungsten Carbide
Body / Support / Flange: Stainless Steel
Electronics Enclosure: SS-316
Ambient Temperature: –20°C to 75°C
Ambient Humidity: 5–95% RH (non-condensing)
Temperature Coefficient: ±0.01% per °C
FL-100 Turbine Flow Transmitter Electronet Series – Industrial Flow Measurement Solution Features
2-Wire System
Simple & Cost-Effective Construction
Local LCD Display
Suitable for Conductive & Non-Conductive Liquids
Electronics Protection: Weatherproof IP65 / IP67
Easy Maintenance
Description
Electronet series FL-100 are 2-wire turbine flow transmitters designed for a wide range of industrial applications.
The flowing media drives a vaned rotor that rotates at a speed proportional to the flow rate. A pick-up coil senses the rotor’s motion and converts it into a pulsating electrical signal.
The frequency of this signal is directly proportional to the flow rate and is further converted into a standard 4–20 mA output signal.
The system also provides totalized flow and real-time flow rate via a local LCD display.
Technical Specifications Performance Characteristics
Media: Liquids
Line Size: 15 NB to 200 NB
Electronics: Integral (Local) / Remote
Viscosity: Up to 100 cP
Display:
LCD, 4-Digit Flow Rate
5-Digit Totalizer
Flow Rate & Totalized Flow via Toggle Key
Remote Cable Length: Max. 15 meters
Output: 4–20 mA DC
Calibration Range: Factory Calibrated (As per requirement)
Accuracy: < ±0.5% of F.S. + 5 mm/sec (Velocity range 0.3 m/s to 6 or 12 m/s)
Linearity: ±0.5% of F.S.
Repeatability: ±0.5% of F.S.
Temperature Coefficient: ±0.01% per °C
Pressure Drop: Approx. 0.28 kg/cm² at max flow
Turn Down Ratio: 10:1
Process Temperature: –20°C to 120°C
Process Pressure: 0 to 10 kg/cm²
Material of Construction (MOC)
Bearings: Tungsten Carbide Sleeve / V-Jewel
Rotor: SS 410 / 17-4 PH
Shaft: Tungsten Carbide
Body / Support / Flange: Stainless Steel
Additional Technical Specifications Electrical
Cable Entry:
M20 × 1.5 (F)
½" NPT (F)
Pluggable Connector
Power Supply: 24V DC, Two-Wire Loop Powered
Power Consumption: < 0.5 VA
Response Time: < 100 mSec
Electronic Protection:
Weatherproof: IP67
Flameproof: CMRI IIA/IIB Certified
Process Connections
ASA 150 RF Flanged (15 NB to 200 NB)
Threaded: 15 NB to 50 NB
SS Tri-Clover: 15 NB to 100 NB
Mounting
In-Line (Horizontal / Vertical)
Ambient Conditions
Temperature: –20°C to 75°C
Humidity: 5% to 95% RH (Non-Condensing)
Certification
CE Certified
ELCMF-200 – Coriolis Mass Flow Meter Features
Flow accuracy: ±0.2% (Optional: ±0.1%)
Diameter range: 15 NB to 50 NB
Flow repeatability: ±0.1%
Density measurement range: 0.3 to 3.000 g/cm³
Density accuracy: ±0.002 g/cm³
Designed based on the Coriolis principle
Highly accurate mass flow and density measurement
Extremely low pressure drop
Direct mass flow measurement without external instruments
Suitable for a wide range of process fluids
Description
The ELCMF-200 Coriolis Mass Flow Meter is engineered using the Coriolis operating principle, delivering one of the most precise and repeatable mass flow measurements available today. It measures mass flow directly, unlike other flow technologies that depend on calculated volumetric flow.
This makes Coriolis meters ideal for applications requiring extremely high accuracy, excellent repeatability, and independence from changing fluid characteristics.
ELCMF-200 offers true mass flow, density, and temperature measurement in a single compact device, with no moving parts and minimal maintenance.
It is widely used across industries such as:
Chemical
Pharmaceutical
Energy
Food & Beverage
Rubber
Paper
Petroleum & Oil & Gas
Its high reliability makes it suitable for batching, loading, custody transfer, and precision flow monitoring.
Advantages
High measurement accuracy: standard ±0.2%, optional ±0.1%
Measurement unaffected by viscosity, temperature, density, or pressure changes
No moving parts → minimal wear and low maintenance
Direct mass flow measurement without external instruments
Measures forward & reverse flow
No need for upstream or downstream straight pipe
Suitable for high-viscosity fluids (crude oil, heavy oil, asphalt, etc.)
No internal obstructions → ideal for slurries, slurry cement, lime slurry, etc.
Handles particulate, viscous, and abrasive media without clogging
Applications
High-pressure gases (CNG, oil & gas sector)
High-viscosity materials (asphalt, grease, heavy oil)
Petroleum products (crude oil, lubricants, coal slurry)
Chemical & pharmaceutical microflow measurement
Materials prone to solidification (bitumen / asphalt)
Suspended or particulate media (cement slurry, lime slurry)
Technical Specifications Flow & Density
Flow Accuracy: ±0.2% (Optional ±0.1%)
Flow Repeatability: ±0.1%
Diameter Range: 15 NB to 50 NB
Density Measuring Range: 0.3 to 3.000 g/cm³
Density Accuracy: ±0.002 g/cm³
Temperature
Process Temperature Range:
–200°C to +300°C
Standard Model: –50°C to +200°C
Temperature Accuracy: ±1°C
Outputs
Current Output (Analog): 4–20 mA (Flow / Density / Temperature configurable)
Frequency / Pulse Output: 0–10, 000 Hz (Open Collector)
Communication: RS-485, MODBUS Protocol
Electrical
Transmitter Power Supply: 18–36 VDC
Power Consumption: < 6W
Mechanical
Protection Class (Flow Tube): IP-68
Material:
Measuring Tube: SS316L
Housing: SS304
Pressure Rating: 4.0 MPa (Standard)
Explosion-proof Rating: Exd(ia) IIC T6 Gb
Environmental
Ambient Temperature: –20°C to –70°C
Humidity: 5% – 95% RH at 25°C
ELMAG-600 Battery / Solar Powered Electromagnetic Flow Meter Features
Battery-powered / Solar-powered design
Suitable for conductive liquids
Full-bore electromagnetic design
Empty pipe indication
Inbuilt data logging facility
Local indication through LCD display
Optional communication port
Simple and cost-effective construction
Maintenance-free, no moving parts
Description
TheElectronet ELMAG-600is a battery-powered electromagnetic flow meter designed for applications where field power is unavailable. It offers complete installation flexibility without compromising performance or accuracy.
With a battery life of2 to 10 years(based on sampling and communication interval), the ELMAG-600 ensures reliable long-term operation. The meter is easy to use, simple to install, and requiresno regular maintenance.
It is ideal formunicipal and industrial water applications, cooling towers, water treatment systems, and domestic installations.
The LCD display indicatesflow rate and totalized flow, and automatically turnsOFF after 10 minutesto save power. It can be reactivated using theEnterkey.
Technical Specifications Process & Media
Media:Conductive Liquid
Line Size:15 NB to 600 NB
Conductivity:> 5 S/cm
Viscosity:Up to 200 cP
Excitation:Pulsed DC
Electronics
Power Supply:Battery Powered / Solar Powered
Mode:Integral / Remote
Display:
LCD
5-digit flow rate
9-digit totalizer
Calibration:
Wet calibrated atIEC / ISO / EN17025 NABL Accredited Facility
Performance
Accuracy:< 1% of M.V. (+5 mm/s for velocity range 0.36 or 12 m/s)
Linearity:0.5% of M.V.
Repeatability:0.2% of M.V.
Temperature Coefficient:0.05% per C
Process Temperature:
20 to 85C (Rubber lining)
20 to 220C (PTFE lining)
Process Pressure:Up to 16 kg/cm (higher on request)
Velocity Range:0.3 2.5 m/s (up to max. 10 m/s)
Mechanical Construction Material of Construction
Lining:Neoprene / Ebonite Rubber / PTFE / PFA / PU / Ceramic
Flange:MS / CS / SS316 / SS304 / PVC
Electrodes:SS316L / Hastelloy-C / Platinum / Tantalum / Titanium
Coil Housing:MS / SS304 / SS316 / PVC
Electronics Enclosure (MOC)
Aluminium Die-Cast
SS316
ABS Plastic
Additional Specifications
Low Battery Indication:Provided
Battery Life:2 to 10 years (depending on sampling interval)
Response Time:< 10 seconds
Electronic Protection Class:
Field Mount: IP-67 / IP-68
DIN Standard: IP-54
Flameproof: CMRI IIA IIB Certified
Sensor / Flow Tube Protection:IP-67 / IP-68
Installation
Process Connections:ANSI 150 flanged (ASME B16.5) Others on request
Mounting:In-line horizontal / vertical
Ambient Temperature:20C to 70C
Humidity:5% to 95% non-condensing
Compact full-bore electromagnetic flow meter
Suitable for conductive liquids
Typical accuracy of 0.5% of M.V.
Protection class: IP-68 (sensor + electronics)
Supports line sizes from 08 NB to 100 NB
Local LCD display for real-time flow monitoring
Robust SS-316 construction for enhanced durability and corrosion resistance
The Electronet TS2000-CP is a compact, full-bore electromagnetic flow meter engineered for accurate and cost-effective flow measurement in pipelines ranging from 08 NB to 100 NB. Built with SS-316L electrodes and PTFE/PEEK insulation, it ensures superior corrosion resistance and long operational life.
The flow meter offers versatile process connection options including Flanged, Threaded, SMS Union, and Tri-Clover, making it suitable for diverse industrial applications. With an IP-68 protection class for both sensor and electronics, it performs reliably even in submerged or harsh environments.
Designed for precision, durability, and ease of installation, the TS2000-CP is widely used in demanding process control applications across water treatment, chemical, food & beverage, and industrial utility systems.
Technical Specifications Performance CharacteristicsMeasuring Principle: Electromagnetic
Media: Conductive liquids
Conductivity: > 5 S/cm
Viscosity: 200 cP
Line Size: 08 NB to 100 NB
Accuracy: 0.5% of M.V.
Response Time: 1 sec
Display: Backlit LCD
6-digit flow rate
8-digit totalizer
Process Temperature: up to 200C
Process Pressure: up to 16 kg/cm
Mounting Orientation: Inline horizontal / vertical
Process Connections:
Flanged
Threaded
SMS Union
Tri-Clover
Ambient Temperature: 20C to +75C
Ambient Humidity: 5% to 95% RH (non-condensing)
Output 1: 420 mA
Output 2: Pulse (Open Collector Type) Optional
Alarm/Relay: 1 Relay Output Optional
Communication: RS-485 MODBUS RTU Optional
Electronics Protection: Weatherproof IP-68
Sensor/Flow Tube Protection: Weatherproof IP-68
Connector: M12
Power Supply: 1830 V DC
Power Consumption: < 5 VA
Electrodes: SS-316L
Wetted Parts: SS-316
Sensor Assembly: SS-316
Electronics Enclosure: SS-316
Features
Compact insertion-type flow meter
Suitable for conductive liquids
No pipe cutting or system shutdown required
Supports line sizes from DN 40 to DN 300
Typical accuracy 0.5% of F.S.
Protection Class: IP-68
Local LCD display for real-time flow rate and totalizer
Rugged SS-316 construction for long-term reliability and corrosion resistance
Technical Specifications Performance Characteristics
Measuring Principle: Electromagnetic flow measurement
Media: Conductive liquids
Conductivity: > 5 S/cm
Viscosity: up to 200 cP
Line Size: 40 NB to 300 NB
Accuracy: 0.5% of F.S.
Response Time: 1 second
Display: Backlit LCD (6-digit flow rate, 8-digit totalizer)
Process Conditions
Process Temperature: up to 200C
Process Pressure: up to 16 kg/cm
Mounting Type: Insertion type
Process Connection: 1" BSP threaded
Ambient Conditions
Ambient Temperature: 20C to +75C
Humidity: 5% to 95% RH (non-condensing)
Output Signals
Analog Output: 420 mA
Pulse Output: Open Collector (Optional)
Relay Output: 1 Relay (Optional)
Communication: RS-485 MODBUS RTU (Optional)
Protection Class
Electronic Protection: Weatherproof IP-68
Sensor / Flow Tube Protection: Weatherproof IP-68
Electrical Connection
Connector: M12 Connector
Power Supply
Voltage Range: 1830 VDC
Power Consumption: < 5 VA
Material of Construction
Electrode Materials: SS-316L
Retractable Assembly: SS-316
Wetted Parts: SS-316
Sensor Rod: SS-316
Electronics Enclosure: SS-316