Process Control Systems & Equipment

Our offered Product range includes Phase Sequence Corrector and Automatic Power Factor Controller.

Phase Sequence Corrector

Elite automatic phase sequence corrector is designed to supply an industrial and domestic for three phase applications.

Ranges: Automatic Phase Sequence Corrector 9 A 400 A

ELITE PSC always gives output 3 phase supply in the right sequence and maintains 120 between phases, even if the input sequence is interchanged. Normally, for any 3 Phase Machines (or) Equipments like AC, UPS, Lifts and Motors, 3 Phase incoming supply has to be given in the right sequence (R, Y, B).

The Phase angle of 120 between the phases R, Y, B is to be maintained to run 3 phases Motors. If the sequence is changed instead of R, Y, B to Y, R, B the motor tends to rotate in the reverse direction. In case of 3 phase UPS, due to wrong sequence, the input supply will be cut and it starts working in the battery mode resulting in draining of battery.

If the sequence is changed for loads like 3 phase AC, UPS and Lifts, they will stop functioning due to the inbuilt sequence protection and only when the input sequence is corrected manually, they start functioning. ELITE Automatic Phase Sequence Corrector always gives an output 3 phase supply in the right sequence and maintains 120 between phases, even if the input sequence is interchanged. Thus all the 3 phase equipments continue to run irrespective of the change in input phase sequence.

Operating functions

  • Whenever three phase input supply is given to ELITE PSC, it checks whether all the 3 phase are alive initially
  • If all the three phases are detected by the Single Phase Preventer (SPP), then it checks and selects the RIGHT SEQUENCE to give always the desired output.
  • In the event of phase failure, ELITE PSC disconnects the load and protects 3 phase equipments from damages.
  • Fully Automatic
  • Output In The Right Sequence(R, Y, B)
  • Voltage Imbalance Protection Between Phases
  • Auto / Manual Mode
  • Single Phase Prevention
  • High / Low Voltage Protection
View Complete Details

Automatic Power Factor Controller

We are pleased to introduce ourselves as the leading supplier of the above product, which is used to maintain the Power Factor (PF) above a specified limit. ELITE APFC Panel has a Micro-controller based Programmable Controller, which switches the Capacitor banks of suitable capacity Automatically, in multiple stages by directly reading the reactive load (RKVA) which works in the Principle of VAR Sensing, tends to maintain the PF to 0.99 Lag. The capacitor banks may be selected in number of stages as 4/6/8 according to the load pattern. The TNEB is installing the Digital Electronic Energy Meters for Power and Welding Service consumers having 25HP and above, which has the provision of showing the PF and insisting to maintain the average Power Factor above 0.85 Lag.

Install ELITE APFC Panel to avoid penalties and enjoy the benefits automatically.

WHAT IS POWER FACTOR (PF)?Power Factor is the ratio between the energy drawings (KVA) and the effective energy utilized (KW) i.e., PF=KW/KVA

WHY POWER FACTOR MUST BE MAINTAINED?By maintaining a better PF we can reduce the energy drawn (KVA), thus reducing the current passing through the electrical circuits to the maximum extent possible (even up to 50%) thereby reducing the down time, reduction in heat losses in turn increases the life of the equipment.

Otherwise, for every reduction of 0.01 from 0.85 up to 0.75 PENALTY is 1% and below 0.75 it is 1.5% from 0.85 of the Current Consumption Charges (KWh) on your Electric Bill.

INCENTIVE is also given by the Electricity Board when the PF is maintained above 0.90 @ 0.5 % for every increment of 0.01 on your Electric Bill.

HOW TO MAINTAIN THE POWER FACTOR?According to the load pattern, proper Capacity of Capacitors to be connected. The value of the capacitors to be connected will vary with respect to the load and its existing PF. There are two ways to maintain PF

1. Fixing the capacitors permanently at the load end or at the mains, generally which is recommended for the fixed loads like Pumps, fans etc., and it is not possible for the loads which have variations in the load and PF.

2. The Power Factor can be maintained by installing ELITE AUTOMATIC POWER FACTOR CONTROL PANEL.

ELITE Controller displays the following parameters.

  • Voltage: R, Y & B Phases, Amps: R, Y & B Phases
  • Present KILOWATT (utilizing current)
  • Present RKVA demand (Required capacitors to attain UNITY power factor)
  • Present KVA (drawing current), Present Power Factor (PF normally 0.99lag)
  • No. of capacitor Banks ON or OFF, Provision to indicate Imbalance load
  • Provision to indicate the change in phase sequence
  • AEEs PF Controller has built-in protections for High voltage cut-off
  • AEEs PF Controller has built-in protections for Low voltage cut-off
  • The values and stages can be made as per customers request
  • Higher Capacity Panels up to 450 KVAR can be supplied against Order

IMPORTANT BENEFITS FOR INSTALLING FOR ELITE AUTOMATIC POWER FACTOR CONTROL PANEL

  • Fully Automatic, no Manual Interventions is required.
  • HEAVY Power Factor PENALTIES on the consumptions are ELIMINATED.
  • INCENTIVES are received on every payment made.
  • Optimize the capacity by reducing the maximum demand KVA.
  • Avoids excess demand charges.
  • Considerable REDUCTION in consumptions (KWH) charges.
  • Improvement in line voltages.
  • Excess Drawing of power is absolutely ELIMINATED.
  • Reduced line current losses and cable overheat.
  • Enhanced life of electrical circuits.
  • Avoids overloading of Distribution Transformers.
  • Additional service connections in existing generation of power by reducing energy losses.
  • Reduced line losses benefits SEBs and Nation.
  • Avail DEPRECIATION as per Income Tax Depreciation Schedule.

OUR PANEL COMPRISES OF

  • VAR SENSING CONTROLLER with LCD display to show all the line parameters.
  • 3 Nos of C.V.Ts (Current Voltage Transducers) of ratio 1:400
  • CAPACITORS of SIEMENS EPCOS make MPP type 440 V / 50 HZ Delta connected
  • CONTACTORS to switch in & switch out the capacitors of ABB / SCHNEIDER/BCH makefixed individually to all the stage capacitors at 440 V / 230 V AC coil.
  • MCB/ 3 Pole as Incomer of ABB / SCHNEIDER make.
  • Provision of INDUCTOR COIL individually to all the capacitors to cater the in- rush currents.
  • To Maintain the OPTIMUM POWER FACTOR load balancing to beCarried out in your Premises compulsorily.
  • After providing our APFC panel the readings of KWH, KVAH, Pr.PF, Avg.PF from theEB meter has to be given to our office once in a week to monitor the improvement of PF.