My ExportersIndia

For Buyer

For Seller

For Help

Our Products

  1. Thermocouple Cables 19 Products available
  2. Limit Controller 6 Products available
  3. Thermocouple 6 Products available
  4. Electrical Cables & Wires 6 Products available
  5. RTD Sensors 5 Products available
  6. Wires 5 Products available
  7. Transmitter Device 4 Products available
  8. Thermocouple Sensors 4 Products available
  9. Temperature Sensors 4 Products available
  10. Temperature Controller 3 Products available
  11. Digital Timers 3 Products available
  12. Silicone Wire 3 Products available
  13. Electronic Connectors 2 Products available
  14. Electronic Controller 2 Products available
  15. Insulated Cable 2 Products available
  16. PTFE Cables 2 Products available
  17. Pneumatic Tools 2 Products available
  18. Digital Indicator 2 Products available
  19. Solenoid Valve 1 Products available
  20. Process Controllers 1 Products available
  21. Pneumatic Machine 1 Products available
  22. Industrial Wires 1 Products available
  23. Measuring Instruments & Equipment 1 Products available
  24. Power Cables 1 Products available
  25. Multicore Cables 1 Products available
  26. Process Control Equipment 1 Products available
  27. Measuring Instruments 1 Products available
  28. Shielded Cable 1 Products available
  29. Braided Wire 1 Products available

Transmitter Device

We offer the best product range of 24V Din Rail Temperature Transmitter, Head Mount Temperature Transmitter, 45V Din Rail Temperature Transmitter and Rtd Pt 100 Temperature Transmitter.

24V Din Rail Temperature Transmitter

3,000 / Piece Get Latest Price
  • Min. Order (MOQ) 10 Piece
  • Accuracy 0.1% For RTD & 0.2% For Thermocouple
  • Brand Name ITHERM
  • Number Of Flower Temperature Transmitters
  • Model Name/Number TMT 131
  • Rated Supply Voltage 24 VDC
  • Response Time 0.3 MicroA
  • Output Type 4 To 20 MA
  • Input RTD PT 100, TC J, K, T, E, N, R, S, B

Features

\n
    \n
  • 2-wire technology, 4 to 20mA analogue output
  • \n
  • High accuracy in total ambient temperature range
  • \n
  • Internal cold junction
  • \n
  • Wide voltage supply range
  • \n
  • Customer specific measurement range setting or expanded SETUP
  • \n
  • Simple and user friendly software
  • \n
  • USB communication
  • \n
\n

 

\n

Specifications

\n
    \n
  • DIN Rail Temperature Transmitter TMT130 for converting various input signals into a scalable 4 to 20mA analogue output signal
  • \n
  • Wide voltage supply range
  • \n
  • Expanded resistance input (max 2KO)
  • \n
  • Expanded voltage input (max 2KmV)
  • \n
\n

 

\n

Technical data

\n
    \n
  • Output: 4 to 20mA
  • \n
  • Supply voltage: 7.5 to 45VDC
  • \n
  • Input: RTD, TC, Ohm, mV
  • \n
  • Cold junction: Internal
  • \n
  • Accuracy(Pt100): <0.2K or 0.08%
  • \n
  • Influence of ambient: Negligible
  • \n
  • Load influence: Negligible
  • \n
  • Power supply influence: Negligible
  • \n
  • Resolution: 0.3uA
  • \n
  • Installation: DIN Rail
  • \n
\n

 

Technical Specification

Output 4 to 20 mA
Supply Voltage 7.5 to 45 VDC
Input RTD, TC, Ohm, mV
Cold Junction Internal
Accuracy (Pt100) < 0.2K or 0.08%
Influence of Ambient Negligible
Load Influence Negligible
Power Supply Influence Negligible
Resolution 0.3 µA
Installation DIN Rail
View Complete Details

Head Mount Temperature Transmitter

1,100 / Piece Get Latest Price
  • Min. Order (MOQ) 10 Piece
  • Accuracy 0.2 %
  • Application Converts RTD & Thermocouple Signals Into 4 To 20mA, Converts RTD & Thermocouple Input Into 4 To 20mA
  • Output Signal 4~20 MA
  • Input Types Temperature
  • Model Number TR 213
  • Output Value 2 Wire, 4 To 20mA
  • Input Value Universal RTD & Thermocouple Input
  • Power 24 VDC

Features

  • 2 wire technology 4 to 20 mA analogue output.
  • High accuracy in total ambient temperature range.
  • An internal temperature sensor for active temperature compensation.
  • Wide voltage supply range.
  • Customer specific measurement range setting.
  • Simple & user friendly software
  • USB Communication

 

Technical Specification

Input RTD, TC, OHM, mV
Output 4 to 20 mA
Supply voltage 7.5 to 45 VDC
Cold junction Internal
Influence of ambient Negligible
Load influence Negligible
Power supply influence Negligible
Resolution 0.3 uA
Installation Sensor head from B
Operation PC - programmable
Weight Approx. 35 GMS
Dimensions 44 MM × 22. 5 MM (Φ × H)
View Complete Details

45V Din Rail Temperature Transmitter

3,000 / Piece Get Latest Price
  • Min. Order (MOQ) 10 Piece
  • Accuracy 0.1% For RTD, 0.2% For Thermocouple
  • Brand Name I TRANS
  • Application Converts All Thermocouple, RTD, MV, Ohms Signals Into 4-20 MA Output
  • Model Name/Number TMT 131
  • Operating Range 0 To 50 C
  • Supply Voltage Limits 7.5 VDC To 45 V DC
  • Output Type 4 To 20 MA
  • Input Type RTD PT 100, TC J, K, N, T, E, R, S, B
  • Configuration USB Cable For Programming With Software

Features

\n
    \n
  • 2-wire technology, 4 to 20mA analogue output
  • \n
  • High accuracy in total ambient temperature range
  • \n
  • Internal cold junction
  • \n
  • Wide voltage supply range
  • \n
  • Customer specific measurement range setting or expanded SETUP
  • \n
  • Simple and user friendly software
  • \n
  • USB communication
  • \n
\n

 

Technical Specification

Output 4 to 20 mA
Supply Voltage 7.5 to 45 VDC
Input RTD, TC, Ohm, mV
Cold Junction Internal
Accuracy (Pt100) < 0.2K or 0.08%
Influence of Ambient Negligible
Load Influence Negligible
Power Supply Influence Negligible
Resolution 0.3 µA
Installation DIN Rail
View Complete Details

Rtd Pt 100 Temperature Transmitter

  • Accuracy ± 0.1%
  • Application Converts RTD And TC Input Into 4 To 20mA
  • Material ABS Plastic
  • Condition New
  • Automatic Grade Automatic
  • Power 24 VDC
  • Storage Condition Head Mounted
  • Number Of Flower Temperature Transmitters
  • Output 4 to 20mA
  • Response Time ≤ 0.8s
  • Power Supply 10 to 32 VDC
  • Sensor Type RTD
  • Output Value 4 To 20mA
  • Input Value RTD PT 100
  • Mounting Head Mount
  • Programming Can Be Programmed With User-friendly Software & USB
  • Damp 0-32s
  • Current Limit ≤ 22mA
  • Saturation Current Low 3.8mA ; High 20.6mA
  • Data Refresh Rate 4 times/sec

Features

\n
    \n
  • 2-wire technology, 4 to 20mA analogue output
  • \n
  • High accuracy in total ambient temperature range
  • \n
  • Internal cold junction compensation
  • \n
  • Wide voltage supply range
  • \n
  • Customer specific measurement range setting or expanded SETUP
  • \n
  • Simple and user friendly software
  • \n
  • USB communication
  • \n
\n

 

Input Output Specifications

Input Specifications
Type RTD PT100
Measurement Range -200 to 850°C
Connection Type 3-wire connection
Output Specifications
Signal Type 2-wire, 4 to 20mA scalable analogue output
Alarm Output 3.6mA or 22mA when sensor damage or break detected

Technical Specifications

Damping 0–32 seconds
Current Limit ≤ 22mA
Saturation Current Low: 3.8mA; High: 20.6mA
Response Time ≤ 0.8 seconds
Data Refresh Rate 4 times/sec
Accuracy ±0.1%
Stability 0.01°C
Power Supply 10 to 32 VDC
View Complete Details