horizontal float switchused to control liquid level in vessels containing corrosive or non corrosive liquids. It is used to control pump, provide alarm, for valve control or level indication.
principle
the float lever carries a permanent magnet which is repelled by similar magnet mounted in the switch housing. The magnet having the same pole directed towards each other are separated by a non magnetic diaphragm. The gland less construction offer excellent sealing.
construction
it consists of 3 main parts :
features
applications :water, oil, fuels, chemical, solvents, syrup etc.
Technical Data
TYPE | NL-100 | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Maximum load | 16 A 250 V AC, AC1 | ||||||||||||||
Cable material | PVC or Neoprene | ||||||||||||||
Contact type | microswitch with NO and NC contact | ||||||||||||||
Contact life | 10 million switches | ||||||||||||||
Switch angle | ±45o | ||||||||||||||
Switching speed | max. 600/min | ||||||||||||||
Process temperature | 0oC to 50oC | ||||||||||||||
Process pressure | max. 0.1 MPa | ||||||||||||||
Liquid density | min. 0.8 g/cm3 | ||||||||||||||
Housing material | non-toxic polypropylene | ||||||||||||||
Protection | IP 68 | ||||||||||||||
Cable specification | Ø 9 mm / 3x1.5 mm2 | ||||||||||||||