My ExportersIndia

For Buyer

For Seller

For Help

Our Products

  1. Thickness Gauge 14 Products available
  2. Metal Testing Equipment 11 Products available
  3. Measuring Instruments & Equipment 10 Products available
  4. Spectrometers 4 Products available
  5. Hardness Tester 4 Products available
  6. Oil Plant And Extraction Machinery 2 Products available
  7. Epoxy Coatings 2 Products available
  8. Measuring Instruments 2 Products available
  9. Material Testing Equipment 1 Products available
  10. Insize Thickness Gauge 1 Products available
  11. Testing Equipment 1 Products available
  12. Laboratory Apparatus 1 Products available
  13. Measurement Gauge 1 Products available

Oil Plant And Extraction Machinery

Our product range contains a wide range of X-RAY XAN-FD Gold Testing Machine For Assaying Refinery & Tunch and X-RAY XAN 250 Gold Testing Machine For Assaying Refinery & Tunch

X-RAY XAN-FD Gold Testing Machine For Assaying Refinery & Tunch

  • Number Of Flower Gold Testing Machine
  • Material Tungsten Tube With Beryllium Window, Silicon PIN Detector
  • Usage Coating Thickness Measurement And Material Analysis
  • Packaging Type Multicolor
  • ApplicationAreas Electronics And Semiconductor Industries, Jewellery And Watch Industries, Research In Universities And Industries
  • XRaySource Micro Focus Tungsten Tube With Beryllium Window, Three Steps 10 KV
  • XRayDetection Silicon PIN Detector With Peltier Cooling, 180 EV (fwhm At Mn-K±)

Gold testing machine in hallmarking centres: XAN-FD is a fast and non-destructive coating thickness measurement and material analysis. These are compact in size and widely applicable as an energy-dispersive X-ray fluorescence measuring instrument.
Our machines are extensively used for non-destructive thickness measurements and material analysis. These are fitted with electrically changeable apertures and primary filters and modern silicon PIN detector for excellent detection sensitivity and high accuracy. These can be used for coating systems as well as solid and liquid Samples can be analyzed standard-free. Besides, these can easily measure up to 24 elements in a Range from aluminum (13) to uranium (92) simultaneously.
Our machines are acclaimed for their long term stability, excellent accuracy, long term stability and ergonomic design. These are very easy to operate and acclaimed for fast calculation and quick data presentation. These are well suited for measuring and analyzing thin coatings, even with very complex compositions or small concentrations.

Design
  • We provide user friendly bench-top instruments. These are available in two different range including XAN-FD and XAN 152 and these differ in support stage and the housing size
  • These are ideal to measure range of up to 22 mm. straightened with the integrated video-microscope with crosshairs and up to 184x zoom factor simplifies sample placement, these devices are very easy to install, operate and maintain
  • These are operated through powerful WinFTM® 2 FISCHERSCOPE® X-RAY XAN®-FD, XAN® 152 -FD, XAN® XAN® 152 software, which make these very user friendly and easy to use.

 

Typical areas of application are
  • Measurement of functional coatings in the electronics and semiconductor industries
  • Analysis of alloys in the jewellery and watch industries
  • Research in universities and in the industries

 

General Specifications

  • Intended use Energy dispersive X-ray fluorescence measuring instrument (EDXRF) to determine thin coatings and alloys
  • Element range Aluminum (13) to Uranium (92), up to 24 elements simultaneously
  • Design Bench-top unit with hood opening upwards
  • Measuring direction Bottom-up method 

 

X-ray source
  • X-Ray tube Micro focus tungsten tube with beryllium window
  • High voltage Three steps 10 kV, 30 kV, 50 kV
  • Aperture (collimator) 4x changeable: 0.2 mm, 0.6 mm, 1 mm, 2 mm, others on request
  • Primary filter 3x changeable: Nickel, Aluminum, free, others on request
  • Measurement spot Depending on the measuring distance and on the aperture in use; the actual
  • measurement spot size is shown in the video image.
  • Smallest measurement spot: approx. 0.3 mm
  • Measuring distance 0 20 mm (0 0.8 in)
  • Distance compensation with patented DCM method for simplified measurements at varying distances. For particular applications an additional calibration might be necessary.

 

X-ray detection

X-ray detector Silicon PIN detector with peltier cooling and Resolution 180 eV (fwhm at Mn-K±)

Sample orientation
  • Video microscope:High-resolution CCD color camera for optical monitoring of the measurement
  • location along the primary beam axis, Crosshairs with a calibrated scale (ruler)
  • and spot-indicator, Adjustable LED illumination of the measurement location
  • Zoom factor:34x . 184x (optical: 34x46x; digital: 1x, 2x, 3x, 4x)

Click Here For More Details


Download Detail File : Click Here

Download


Download Detail File : Click Here
View Complete Details

X-RAY XAN 250 Gold Testing Machine For Assaying Refinery & Tunch

  • Material Metal and Plastic
  • Number Of Flower Gold Testing Machine
  • Usage High-precision Analysis Of Precious Metals For Hallmarking And Assay Offices
  • Environmental Conditions 10°C - 40°C / 50°F - 104°F, 0°C - 50°C / 32°F - 122°F, 95%, Non-condensing
  • Evaluation Unit Windows-PC, Standard: Fischer WinFTM BASIC Including PDM, Optional: Fischer WinFTM SUPER

The high-end measurement system Fischerscope X-Ray XAN 250 was developed specifically for high-precision analysis of precious metals as required for Hallmarking and assay offices. Gold testing machine in assaying centres: XAN250 is engineered using best available techniques. These are high performance X-ray fluorescence measuring instruments widely used for fast and non-destructive material analysis and coating thickness measurement. Compact sized these devices are acclaimed for high performance, longer service life and accurate measurement.

Environmental Conditions

  • Temperature Operation:10°C 40°C / 50°F 104°F
  • Temperature Storage/Transport: 0°C 50°C / 32°F 122°F
  • Admissible air humidity:95 %, non-condensing


Evaluation Unit

  • Computer:Windows®-PC
  • Software:Standard: Fischer WinFTM® BASIC including PDM®
  • Optional: Fischer WinFTM® SUPER

Details 01

Application

  • Gold Purity Testing
  • Gold Coating Thickness
  • Gold analysis in manufacturing, refinery and Hallmarking centres.
  • Measurement of functional coatings, starting from a few nanometers, in the electronics and semiconductor industries
  • Trace analysis for consumer protection, e.g. lead content in toys
  • Analysis of alloys with highest requirements of accuracy in the jewellery and watch industries and in metal refineries
  • Research in universities and in the industries

 

 

 

Design

  • These are available in two different range including XAN 250 and XAN 252.
  • These are user friendly devices acclaimed for compact size and consistent performance.
  • Our devices are acclaimed for their quick and easy sample positioning and consistent performance.
  • These are fitted with the X-ray source and semiconductor detector which are further located in the instrument‘s lower chamber.
  • Engineered under the firm direction of experienced quality controllers, these are fitted with the integrated video-microscope with zoom and crosshairs simplifies sample placement which further allows precise measuring spot adjustment and ensure clear presentation of measurement data on a PC with the help of powerful and user-friendly WinFTM® software.
  • These are designed and developed in accordance with German regulations "Deutsche Rontgenverordnung-rov".

 

 

 

 

Specification

Intended use

Energy dispersive x-ray fluorescence measuring instrument (EDXRF) to determine thin coatings, Gold Testing, Gold analysis, trace elements and alloys

Element range

Aluminium (13) to Uranium (92) up to 24 elements simultaneously

Design

Bench top unit with upwards opening hood

Measuring direction

Bottom up

 

 

 

X- Ray Source

X-ray tube

Micro-focus tungsten tube with beryllium window

Aperture (Collimator)

4x changeable: 0.2 mm (7.9 mils), 0.6 mm (23.6 mils), 1 mm (39.4 mils), 2 mm (78.7 mils), others on request

Primary filter

6x changeable: Ni, free, Al 1000 m (39.4 mils); Al 500 m (19.7 mils); Al 100 m (3.9 mils); Mylar 100 m (3.9mils)

Measurement spot

Depending on the measuring distance and on the aperture, the actual measurement spot size is shown in the video image. Smallest measurement spot: approx. 0.3 mm (11.8 mils)

 

 

 

X-Ray Detection

X-ray detector

Silicon Drift Detector (SDD), peltier-cooled Resolution (fwhm for Mn-K±) 160 eV

Measuring distance

0....10 mm (0...0.4 in)  Distance compensation with patented DCM method for simplified measurements at varying distances. For particular applications or for higher demands on accuracy an additional calibration might be necessary.

 

 

 

 

Sample Stage

Design

Fixed sample support

Usable sample placement area

310 x 320 mm (12.2 x 12.6 in)

Max. sample weight

13 kg (29 lb)

Max. sample height

90 mm (3.5 in)

 

 

Dimensions

External dimensions Width x depth x height

403 x 588 x 365 mm (16 x 23.2 x 14.4 in)

Weight Approx.

45 kg (99 lb)

Details 02

Standards XAN 250 XAN 252
CE approval EN 61010 EN 61010
X-Ray standards DIN ISO 3497 and ASTM B 568 DIN ISO 3497 and ASTM B 568
Approval Fully protected instrument with type approval according to the German regulations "Deutsche Rontgenverordnung-RoV". Individual acceptance inspection as a fully protected instrument according to the German regulations "Deutsche Rontgenverordnung-Ro

Download


Download Detail File : Click Here
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us