Our Products
We offer the best product range of PNEUMATIC CONVERTER, NITROGEN DIOXIDE DETECTOR, Integrated Gas Trains, Honeywell FCU Valve and Baumer Temperature Gauges.
TheI/P converter with various housing is available for cabinet installation, field installation, rail installation and as slide-in type. The signal conversion is based on standard signals. Current signals 0/4 to20 mA are converted to pressure signals 0.2 to 1 bar or 3 to 15 psi.
General specifications:
Greystone WallSurface Mount Carbon Monoxide Detector without LCD Dispaly, Range 0-300 PPM, Output 4-20mA , Power Supply 24VDCAC
Additional Information:
Delivery Time : Ex Stock
Ex Intrinsically Safe Mobile Computeris the best choice for workers in the chemical, oil and gas, mining and pharmaceutical industries.It meets or exceeds stringent requirements for gases, vapors and liquids, dusts and fibers.
High Volume Portable Mobile Label Printeris a 76.2 mm (3 in) direct thermal portable label printer that delivers greater paper capacity, long battery life and a range of wireless connectivity options for the retail and manufacturing marketplace.
FEATURES:
Class MCompact Barcode Printersoffer a great value for warehouse, healthcare, logistics and retail applications. Itkeeps up with high-label-demand applications, boasting faster performance than many printers in its class. The modular design and field-installable options cut back on downtime and improve efficiency.
FEATURES:
LKS 160air damper actuator is designed to be fitted to multi-stage or modulating oil and gas burners with fully closed position.
A synchronous motor powers a drive shaft and a backlashfreecam shaft via a gear reducer. The cam shaft operates limit and auxiliary switches. Theposition at which one of the limit or auxiliary switches operatescan be adjusted steplessly within the operating range usingthe associated cam disc. Manually adjustable lever-operatedcams or spindle-driven cams, which can be adjusted with ascrewdriver, are available.
The NDD Series nitrogen dioxide detector uses a superior electrochemical sensor for reliability and accuracy in the most critical applications. The NDD provides a 3-wire sourcing 4-20 mA output as well as an alarm relay with three jumper selectable trip level settings.
Measurement Range :0-10 PPM, Output Signal :4-20 mA, Adjustable Alarm Relay
FEATURES:
The CMD5B5 Series Duct Carbon Monoxide Detector uses an electrochemical sensor to monitor the carbon monoxide level and outputs a eld-selectable 4-20 mA or voltage signal. The voltage signal may also be set to 0-5 or 0-10 Vdc. The sensing range and output may be scaled to either 100, 150, 300, 400 or 500 ppm via the on-board menu. A front panel LCD is standard to ensure easy setup and operation.
Y-type strainer is widely used in water application and is used for protecting valve and other equipments from scrap and impurities in the system.
FEATURES
feature 5.6-inch TFT color LCD (640480) touchscreen displays with excellent visibility and intuitive control interface. It supports 27 types ofinput withhigh-speed sampling rate up to 25 ms and recording cycle between 1 to 3600sec. Various communication methods (USB, RS422/485, Ethernet) also supported.
AUTONICSSPB SeriesSwitching Mode Power Suppliesoffer high power conversion efficiency and stable power supply with low noise and ripple and minimal heat generation.The switching mode power supplies can be easily clipped onto DIN rails or mounted using screws.The slim and compact design also allows space-saving installation.
AUTONICSE50S Seriesdiameter 50mm shaft type incremental rotary encoder are suitable for measuring angle, position, revolution, speed, acceleration and distance.
Serieshigh performance fiber optic amplifier, features a compact structure designed to fit into narrow spaces. This fiber optic amplifier has fast response speed of under 0.5ms, and can be compactly mounted. Also, external synchronization input function, mutual interference protection and self-diagnosis function enhance user experience.
| features |
|
| typical applications |
|
Greystone Differential Pressure Transmitter, Range 250Pa, 500Pa, -1000Pa selectable, Output 4-20 (2wire) 0-10 (3 wire) selectable, Supply 24VAC DC
Additional Information:
Delivery Time : Ex Stock
Greystone Differential Pressure Transmitter, Range 6", 10", -12" selectable, Output 4-20 (2wire) 0-10 (3 wire) selectable, Supply 24VAC DC
Additional Information:
Delivery Time : Ex Stock
Greystone Differential Pressure Transmitter, Range 10", 15", -20" selectable, Output 4-20 (2wire) 0-10 (3 wire) selectable, Supply 24VAC DC
Additional Information:
Delivery Time : Ex Stock
HONEYWELLIgnition TransformerET 401for Gas, Supply 230VAC, Secondary Voltage 14KV
the tzidc represents the digital, intelligent positioner for communication via hart within thepositioner family. Unmatched shock and vibration immunity of 10g up to 80 hz distinguishes the tzidc from others and guarantee reliable operation in almost all areas under harshest environmental conditions.
the tzidc represents the digital, intelligent positioner for communication via hart within thepositioner family. Unmatched shock and vibration immunity of 10g up to 80 hz distinguishes the tzidc from others and guarantee reliable operation in almost all areas under harshest environmental conditions.
general specifications:
Working Principle & Operation:
It is simple and reliable switch for level detection.It can be used for small or long range of storage tanks and reservoirs. Polypropylene rigid construction provides prevention from corrosion.Float tilt with liquid in rise & fall condition, accordingly micro switch operates from NO (Normally Open) to NC (Normally Close) position. It can be used as a multi point switch also.
Special Features:
Application:
honeywellmicro switchdm-dp seriessnap-in panel mount basic switchesare snap-action switches in basic and manual configurations. They have quick-connect terminals and snap-in, panel mount housings for ease of installation. They include momentary and alternate actions, and single- or double-pole. The dm accept a button for manual operation. The dp have plungers for basic operation.
| features | ||
|
pid controlleris economical temperature controllers having dual preset indicator display to increase user convenience.the series realizes ideal temperature controlling with newly developed pid control algorithm and 100ms high speed sampling. Thisseries allows users to take advantage of economical controlling with ssrp and relay outputs.the tcn series is also available in low voltage models for wider user options.
Wall mounted line voltage room thermostat. For general purpose control of gas valves, zone valves, circulation pumps, ventilators, boilers etc. In heating or cooling systems. Approvals ce protection class ip30 switch functioncapacity spdt 230 vac, heating terminal 10 a resistive, 3 a inductive; cooling terminal 6 a resistive, 2 a inductive terminal max. Wire size 4 mm2 erp class I temp. Setpoint range 10 . 30 oc differential fixed 1 oc temperature element vapour filled temp. Element place built in heating cooling application h or c earthing double insulated housing (hxwxd) 83 mm 83 mm 40 mm additional description lamp is generally supplied potential free, and can be wired to indicate heating or cooling operation, or boiler lockout.
Additional Information:
Delivery Time : Ex Stock
Reversible gear motors to transmit rotary movements between 0 and 90 or 0 and 160, for actuation of gas and air valves, with voltage-free limit switches, automatic/manual mode changeover (optional), position feedback and externally readable position indicator. Running times: 3.7 to 214 s, mains voltage: 24 V AC, 110/120 V AC or 220/240 V AC, torque: 1.2 to 20 Nm, controlled by three-point step signal, continuous signal or two-point signal.
More Information:
Microprocessor, electronic components, output relais and flame amplifier are placed on two printed circuit boards. These plus the lockout- and reset circuit are well protected inside a flame resistant, plug-in type plastic housing. The reset switch for reset / remote lockout with its built-in LED for displaying the information system plus the central fixing screw are placed on top of the housing. The wiring base S98 is equipped with spare- and extraterminals and allows together with a variety of cable entry points utmost flexibility of electrical wiring.
The burner control box DLG 974/976 controls and supervises
power burner for gas and dual fuel. The control box is
approved and certified according the relevant European
standards. The use on direct air heaters according DIN 4794
is also possible.
The microprocessor- based programming sequence ensures
extremely stable timings independent of voltage variations,
ambient temperature and/or switch-on cycles. The
built-in information system not only provides a continuous
monitoring of the actual state of the box (very helpful especially
for monitoring the start-up phase) but also informs
about the cause of a possible lock out. The lock out cause
is stored in such a way that it can be retrieved even after a
power failure.
The control box is designed for maximum safety in case of
fluctuations in the voltage supply. If the mains voltage drops
below the permitted level, operation is interrupted and the
control box automatically prevents the start sequence from
being repeated. In this way, the safety of the system is not
put at risk by a drop in the mains voltage. This low-voltage
protection works not only during start-up but also permanently
during operation.
The Honeywell DBC2000 is a microprocessor-based integrated burner control for automatically fired gas, oil or combination fuel industrial single burner power burner applications. The DBC2000 system consists of the relay module and wiring subbase. The DBC2000 Standard Model provides the minimum requirements to control an industrial burner system, such as automatic burner sequencing, flame supervision, system status indication, system or selfdiagnostics and troubleshooting. The DBC2000 Enhanced Model includes an integrated Valve Proofing System, as well as well as bus communication.
The DBC2000 is programmed to provide a level ofsafety, functional capability and features beyond thecapacity of conventional controls.
FEATURES
Employs a plug-in mounting methodUses a microprocessor to improve performanceThe progress of the sequence can be easilydetermined by status indicator LEDsAll models have a 4-wire firing rate switchingcircuit to control an air damper or other auxiliaryequipment during startup of the burner.Safe start check before and during pre-purgeSafety shutdown occurs on- malfunction of the burner controller- failure to ignite the pilot burner or main burner- loss of flame during run period- opening of air flow switch during pre-purge, start-up, run and post-purge period- flame signal detection during standby or prepurgeperiodRemote communication (Enhanced model only)Valve Proofing System (Enhanced model only)
Mains input: Supply voltage220 to 240Vac -15% +10% 50/60Hz or110 to 120Vac -15% +10% 50/60Hz
Allowable ambient Temperature & Humidity-10 C; +60C90% RH max. at 40C (non condensing)
ApprovalsCE certification to standard EN298:2003CE certification to standard EN230:2005
Additional approvals:Lloyds (planned)EN746-2 compliantPED (planned)SIL2 (planned)Apave (planned)
Honeywell BC1000A0220F FLAME SWITCH, 2 1 Sec. flame response time, C7012A/C7012G flame sensor connected, 220230Vac, 50/60Hz, 5W Power Consumption.
The Honeywell DBC2000 is a microprocessor-based integrated burner control for automatically fired gas, oil or combination fuel industrial single burner power burner applications. The DBC2000 system consists of the relay module and wiring subbase. The DBC2000 Standard Model provides the minimum requirements to control an industrial burner system, such as automatic burner sequencing, flame supervision, system status indication, system or selfdiagnostics and troubleshooting. The DBC2000 Enhanced Model includes an integrated Valve Proofing System, as well as well as bus communication.
FEATURES
Employs a plug-in mounting methodUses a microprocessor to improve performanceThe progress of the sequence can be easilydetermined by status indicator LEDsAll models have a 4-wire firing rate switchingcircuit to control an air damper or other auxiliaryequipment during startup of the burner.Safe start check before and during pre-purgeSafety shutdown occurs on- malfunction of the burner controller- failure to ignite the pilot burner or main burner- loss of flame during run period- opening of air flow switch during pre-purge, start-up, run and post-purge period- flame signal detection during standby or prepurgeperiodRemote communication (Enhanced model only)Valve Proofing System (Enhanced model only)
The gas governors are conformity with EN 88 standard (2009/142/CE gas regulation). The governors are suitable to systems' installation with automatic gas burners including mixed and combined systems and to in industrial distribution systems.
TECHNICAL FEATURES
Compensation diaphragm, operating diaphragm andsafety diaphragm: an external breather outlet pipe is notnecessary as the incorporated safety diaphragm ensuresthat, in the event of breakage of the operating diaphragm, no gas leakage (over 30 dm3/h) is possible inside theroom (in compliance with par. 3.3.2. EN88specifications).
INSTALLATION
Install the governor with the diaphragm positionedhorizontally (on horizontal pipes). Be careful to followalways the direction of gas flow indicated by the arrow onthe governor.Suitable tools must be used for the governor fitting on theinlet and outlet hubs. Never effect leverage on the sleeveof the upper cover when fitting the governor.For all models with the filter inside, the governor is bestfitted at a comfortable height from the ground so as tofacilitate the filter cleaning (fit always a suitable gas filterupstream the governor).Make sure that the pipes are clean and aligned so thegovernor is not under stress.Do not remove the perforated diaphragm breather cap (3)and do not obstruct the hole, otherwise the governor willnot work. Install the governor so avoiding contact withplastered walls.Make sure that the governor is suitable to the intended use.
The BIO burner is designed for industrial furnaces and firing systems in the iron and steel industries in the precious, non-ferrous, and light metal sector, as well as in the plastics, fiber, and paper industries. Other fields of application are thermal incineration installations, as well as dryers and hot-air generators. For low temperature applications (e.g. for crucible heating, radiant tube heating, or hot-air generation), the burners are equipped with a heat-resistant steel attachment tube. For high temperature applications (e.g. forging furnace), the burners are used in combination with a burner quarl made from refractory concrete. Different flame shapes can be achieved by using burner quarls with a different geometry. The burner can be adapted to the system requirements using different burner tube lengths.
AIR-300: The AIR-300 is a microprocessor based air quality monitor/controller sensitive to a wide variety of air pollutants.
FEATURES
APPLICATIONS
DESCRIPTION
The AIR-300 is a microprocessor based air quality monitor/controller utilizing a hot wire element sensor based upon the Taguchi principle. This is a full spectrum sensor sensitive to a wide variety of air pollutants such as carbon monoxide, smoke, benzene, alcohols, hydrogen, hydrocarbons, esters, etc.
This sensor is better suited to measuring air quality than a sensor which measures only Carbon Dioxide. The AIR-300 yields a true indication of the actual air quality, rather than occupancy. For example, if a person were to smoke a in a room, the carbon dioxide sensor would be inadequate in detecting this, even though the air quality had significantly degraded. This same set of circumstances holds true for many other contaminants such as Solvents, Fuels, and even Carbon Monoxide, all of which are much more harmful than Carbon Dioxide.
When measuring Air Quality, it is not so much the type of contaminant that is of concern, but rather the presence of any contaminants. This sensor does not indicate which contaminant is in the air, but indicates the presence and quantity of any contamination.
The Greystone AIR-300 monitor/controller works by looking at the signal from a full spectrum sensor, automatically compensating for temperature and humidity effects, and judging the degree of pollution. For the unit to perform efficiently it must work as a monitor/controller, i.e. it must be able to act upon level changes. The output is represented as an analog, stepped or relay output with user adjustable settings. This output can be used to directly control an actuator, or be sent back to a Building Automation System (BAS).
The AIR-300 can be configured to run in auto or manual mode and has an integral sensitivity adjustment to provide the user with the optimum settings to monitor a specified area. There are internal LED indicators to show microprocessor status and also a manual override feature to assist in installing the unit.
Thyristor Power Controller Multidrive 2PH up to 2700A 3 wire / 24Vac to 690Vac Supply / 4-20mA or 0-10V DC linear inputs, 10K Pot or RS485 Comms input / Burst Firing, Delayed Triggering + Burst Firing.
Ideal for:normal resistive & transformer coupled with normal resistive load types
Multidrive is a fully digital and universal Thyristor Power Controller designed to drive 2 legs of 3 phase resistive & transformer load types. Available in 19 Amp sizes from 45A to 2700A the Multidrive provides the user with optimum control of the process and ease of set-up & maintenance. The Front panel keypad & display allows total flexibility for the user with full configuration of the process & digital inputs types and firing & control modes, to suit the application. Real time values such as the Voltage, Current & Power can be read from the display. Internal quick-blow fuses as standard provide complete protection for the thyristor. Additional features such as current limit, profiling, heater break alarm and RS485 comms come as standard.
Overview:
Thyristor - CD3000M 2PH 15A to 700A DC Logic/Linear, ZC/BF 24V to 600VAC Supply, DC Logic, 4-20mA, 0-10V DC linear or 10K potentiometer inputs. CD3000M-2PH is a digital and universal Thyristor unit fully configurable via serial communication port.
A fully digital and universal Thyristor, configurable via RS485 serial communication port or dedicated configuration port for all inputs, firing & performance parameters.Configuration software available as a download at no cost.
Overview:
Multidrive is a fully digital and universal Thyristor Power Controller designed to drive most load types. Available in 8 Amp sizes from 850A to 2700A the Multidrive provides the user with optimum control of the process and ease of set-up & maintenance. The Front panel keypad & display allows total flexibility for the user with full configuration of the process & digital inputs types and firing & control modes, to suit the application. Real time values such as the Voltage, Current & Power can be read from the display. Internal quick-blow fuses as standard provide complete protection for the thyristor. Additional features such as current limit, profiling, heater break alarm and RS485 comms come as standard.
Overview:
The GKN Series safety interlock switches provide superior reliability in a compact, cost-effective package size. Six different types of actuator keys are available. The GKN Series conforms to IEC 60947-5-1 and carries cULus, CE, CCC, and SIL 3 capable approvals.
| Features |
|
| Potential Applications |
|
Additional Information:
Delivery Time : Ex Stock
SECURECurrent Transducers offers accurate true RMS measurements. Upto for load independent galvanically isolated analog ouptputs can be configured for desired input range. Theses transducers comply with IEC60688.
SECUREPower Transducers offers accurate true RMS measurements. Upto for load independent galvanically isolated analog ouptputs can be configured for desired input range. Theses transducers comply with IEC60688.
SECUREFrequency Transducers offers accurate true RMS measurements. Upto for load independent galvanically isolated analog ouptputs can be configured for desired input range. Theses transducers comply with IEC60688.
autonicstm seriesmodular type pid temperature controllers are capable of controlling up to 4 channels (tm4) or 2 channels (tm2) simultaneously.the temperature controllers feature high-speed sampling cycle (4-channel: 100 ms / 2-channel: 50 ms), rs485 communication support, and simultaneous heating and cooling control.
.