Operating Humidity : 5% To 95% RH (non-condensing)
Enclosure : ABS Plastic
Isolation : 1.5 KV Between Input, Output & Power Supply
Features : Single Input With Dual Isolated Outputs,Signal Conversion With Complete Electrical Isolation,Dedicated Input Type,High Accuracy: Better Than ±0.25% F.S.,Operates On 24V DC Supply,Compact And Maintenance-friendly Design,DIN Rail Mounting,Reliable And Cost
Isolation : 1.5 KV Between Input, Output & Power Supply
Features : Single Input, Single Output,Signal Conversion With Electrical Isolation,Dedicated Input Type,High Accuracy: Better Than ±0.25% F.S.,Operates On 24V DC Supply,Compact Size For Easy Installation & Maintenance,DIN Rail Mounting,Reliable And Cost-effective D
Signal isolator is a rugged 4 wire isolator available in compact DIN rail mounting enclosure designed to accept custom built and wide range of voltage and current input signals. Signal is isolated and converted to standard instrumentation signals compatible to commercially off...
Features : Slim Design of 12.5mm for Single output and 17.5mm for Dual output,1.5KVAC Three Port Isolation,High CMRR and NMRR,Front calibration facility Via mutiturn Trimpot
Slim Signal Isolator 9000C is slim yet rugged 4 wire Isolator used for reliable Isolation and Attenuation of Industry Standard Field Signals. 9000C is available in Single or Dual output models. Slim Signal Isolator 9000C has higher noise rejection ratio that ensures accurate and...
The rs 232 serial port isolator � iso 232 m is primarily intended to provide complete isolation between expensive computer or system from the serial device, so that they are protected against any inadvertent damage due to electrical...
Signal Isolator ISO102 series (single output or dual output) provides total signal isolation between a non-isolated transmitter and a receiving device. This eliminates faulty readings in process measurement and control equipment caused by ground loops, motor noise, and other...
We are offering signal converters, isolators and transmitters to isolate and convert field signals like resistance, current, voltage, frequency to 4-20 ma. These isolators find use in process control industries for signal isolation. Variety of models is available for specific...
Protocontrol offers signal multipliers to isolate field signals like 4-20 ma and multiply them to up to four for processing them at four different locations. Hence one 4-20 ma input can be used for location indication, remote monitoring as well as data acquisition. These...
We offers signal isolators to isolate and convert field signals like resistance, current, voltage, frequency to 4-20 ma. These isolators find use in process control industries for signal isolation. Variety of models is available for specific applications. transmitters are the...
Accuracy : For Thermocouple and RTD Input, the calibration of output is done for the best straight line fit to give accuracy of /- 0.5% of the range. For other input the linearity depends on the input signal, where output accuracy is absolute to the input.
Calibration : On site calibration facility through ZERO and SPAN presets accessible to the user.
Input types : RTD (Pt-100) / 2 or 3 wire or Thermocouple (J/K/ Types – type to be specified) or mV, mA input or Load cell, pressure sensor, pH/ORP sensor etc. generating DC current or voltage. AC input - Current (through external CT) (0-1)A or (0-5)A or Voltage (0-11
Isolation : Input and Output are optically isolated for DC and frequency inputs and galvanically isolated for the AC inputs.
Size : 65(W) x 80(H) x 125(D) mm.
Supply Type : Supplier
Supply : 90 -260 VAC, 50/60Hz or 24VDC @ 200mA
Output : (4-20) mA, (0-20) mA, (0-1) VDC, (0-5) VDC, (0-10) VDC, Frequency (0-1)KHz, (0-5)KHz, (0-10)KHz etc. proportional to the specified input range. For current output, RL (max.) = 500 Ohms. For voltage output, RL (min) = 10K Ohms.
We have separated our infrastructural facility into several units and one of them in warehouse. In order to maintain high quality standards, we laced our facility with modern technology. In order to attain complete client credibility, we offer...
Safety and reliability have been a challenge in today�s coal fired boilers at thermal power stations. FOURESS, in technical consultation with a few discerning customers have developed the perfect solution to the pressing problem of effective isolation of PF mills. This...
Input (Single or dual): Voltage(ACDC) Current(ACDC) Power( KWW) â�¢ Transmission OP (DualSingle): Linear current (4 20 mA) or voltage (0-10VDC) â�¢ Power supply: 230VAC or 110VAC , 50 Hz â�¢ Re transmission accuracy: 0.2%FS�± 1 Digit...