-
Min. Order (MOQ)
1 Piece(s)
-
Brand Name
Contec
Cms 9000 multipara monitorwe offer cms 8000 model are known for their wide functionalities. These are used to report respiration, spo2, ecg, temperature, resp, monitor, essential measurement parameters such as spo2, temp, ecg, pr/hr, resp and nibp. These monitors are designed by latest digital technology which gives excellent accuracy. we have with us cms 8000 multipara monitors that are designed using latest technology and as per the international standards. Procured from our reliable vendors, these monitors are compact in size and are easily portable. These monitors are incorporated with adjustable audible and visual alarm and other safety features. Further, our monitors are available in different specifications and at industry leading prices. features: -some features of the products are as follows : color tft screen, waveform up to 8 channelslight and portable with build-in rechargeable batteryup to 10 kinds of monitor parametersarrhythmia analysis, pace-marker detection and s-t segmentanalysis72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo rms. built-in recorder(option)all-round monitor of adult, pediatric and neonatal. electrosurgical unit and defibrillation protectedstandard parameters: ecg, nibp, spo2, respiration, temperature, pulse rateoption parameters: etco2, co, ibp, thermal printer ecg :5-lead or 3-lead selectableinput: 5-lead: ra; la; rl; ll; v or r; l; n; f; clead selection: i; ii; iii; avr; avl; avf; vx; calgain selection: 12.5mm/s, 25mm/s, 50mm/saccuracy: 1bpm or 1%, whichever is greaterprotection: withstand 4000vac/50hz voltage in isolation against electrosurgical and defibrillationcalibration signal: 1mv 5%operation modes: diagnostic, monitor, surgeryalarm range: adult: 15-300bpmpediatric/neonatal: 15-350bpmalarm range: -2.0mv2.0mvs-t detection: yes, arrhythmia analysis: yesalarm: yes, audible and visual alarm, alarm events recallable nibp method: oscillometryoperation modes: manual/automatic/statmeasurement unit: mmhg/kpa selectablemeasurement types: systolic, diastolic, meanmeasurement range: adult: 10-270mmhgover-pressure protection: yesresolution: 1mmhgaccuracy: mean error and standard deviation per ansi/aami sp-10alarm: systolic, diastolic, mean spo2 measurement range: 0-100%accuracy: 2digit (70100%);069% unspecifiedalarm range: 0-100% respirationmethod: ra-ll impedancepediatric/neonatal: 6-150rpmalarm range: adult: 6-120rpmpediatric/neonatal: 6-150rpmapnea alarm: yes temperatureresolution: 0.1channel: dual-channelalarm range: 0-50 option:etco2measurement mode: side-stream or mainstreammeasurement range: etco2: 0-99mmhgaccuracy: co2 concentrationapnea alarm: yes comethod: thermo-dilutionmeasurement range: co: 0.1-20 lit. /min. ibpchannel: 2 channelspressure transducer: sensitivity: 5( mv/v/mmhg)transducer sites: art, pa, cvp, rap, lap, icpalarm range: -10300mmhg