Post Buy Requirement
ME
Delhi, India
Verified Add Review

Our Products

  1. LED Lights 5 Products available
  2. Medical Equipment & Supplies 4 Products available
  3. Computer Monitor 8 Products available
  4. Surgical Equipment & Supplies 7 Products available
  5. Medical Ventilators 3 Products available
  6. ECG Machine 4 Products available
  7. Pulse Oximeters 3 Products available
  8. Others 19 Products available

Surgical Equipment & Supplies #131325

Physio Control Life Pack 9 Defibrillator

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Life Pack
We are offering physio control life pack 9 defibrillator. physio control defibrillator. we offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are: physio control defibrillator we offer defibrillator physio control monitor, which is designed to meet the needs of clinical, biomedical engineering, and purchasing professionals throughout the world. This units simple 1-2-3 operation and user-friendly display, plus its compact, portable, space-saving design, revolutionized in-hospital de fibrillation. simple, logical controlsuser-friendly displayscode summarycritical event recordspace savingvertical designoptional shockadvisory system innovative features :high and low energyselect displaysannotating recorderauxiliary paddles for hands-free de fibrillation. designed for ease of maintenancediagnostics for simple test and calibration
View Complete Details

Defibrillator

  • Min. Order (MOQ) 1 Piece(s)
Zoll pd 1200we offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are: zoll pd1200 the zoll pd 1200, combining defibrillation, pacing, and monitoring, offers complete acls-response capabilities in a single, easy-to-use unit that is ideal for critical and specialitycare areas. It can be configured with the zoll "hands-off" multi-function electrodes, with standard defibrillation paddles and pacing electrodes, and with internal defibrillation paddles and pacing electrodes. The zoll pd 1200 operates on both ac line and battery power and is completely compatible with all models in thezoll cardiac resuscitation system. features :innovative features :large monitornon-fade monitor. ecg monitor. strip recorder. ac power supply for stationary use. specifications:pacemakertype: vvi demand; asynchronous (fixed rate)when used without ecg leads. pulse type: rectilinear, constant current. pulse duration: 40 milliseconds. pulse amplitude: variable to 140 ma. pacing rate: variable from 30 to 180 ppm. output protection: fully defibrillator-protected and isolated. pacer on: message display on monitor. defibrillator :waveform: damped sinusoid. output energydelivered: selectable at 2, 3, 5, 7, 10, 20, 30, 50, 100, 150, 200, 300, 360 joules. charge time: less than 10 seconds. delivered energydisplay: crt monitor displays delivered energy. synchronized mode: synchronizes defibrillator pulse to patients r-wave. sync messagedisplayed on monitor. Marker on monitor and on recorder paper identifies r-wave. internal paddles: output limited to 50 joules when internal paddles are connected. Discharge from paddles. charge controls: control on apex paddle and front panel. paddles: standard paddles are anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles. defibrillation electrodes: specifically designed zoll multi- function electrodes used in anterior/anterior or anterior/posterior positions; packaged in pairs. integral defibrillator tester: integral circuitry allows complete test of defibrillator charge and discharge without removing paddles from storage wells. identical circuitry allows complete test of unit configured with multifunction cable. defib on: message display on monitor. monitor and displaypatient connection: via 3-lead ecg cable, paddles, and elec trodes. Selectable by front panel switch. input protection: fully defibrillator-protected. Special circuit prevents distortion of ecg by pacer pulse. bandwidth: .5 40 hz (3db) standard. display format: nonfade, moving trace with freeze capabilitymonitor on: message display on monitor. screen type: high-resolution crt display. screen size: 5 inches diagonally (108 mm x 85 mm viewing area). sweep speed: 25 mm/sec. viewing time: 4 seconds. heart rate: digital display on monitor 0 300 bpm. pacer output current: digital display on monitor 0 140 ma. ecg lead selection: display on monitor. ecg size: .5, 1, 2 cm/mv display on monitor. alarm on/off status: display on monitor. User selectablehigh (60 280 bpm)low (20 100 bpm). ecg lead off: message display on monitor. pacer electrode off: message display on monitor. defibrillator paddle fault: message display on monitor. defibrillator electrode fault: message display on monitor. recorder paper out: message display on monitor. low battery voltage: message display on monitor.
View Complete Details

Defibrillator

  • Min. Order (MOQ) 1 Piece(s)
OLL PD 2000We offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are: Zoll PD 2000 The ZOLL PD 2000 Advisory Defibrillator/Pacemaker is the first device designed as a completely integrated system for early defibrillation and advanced cardiac life support in the hospital. The built-in ventricular fibrillation detection system eliminates adapters and a "paddlefree" electrode system is easily applied to speed shockdelivery and external pacing. Standardized controls make it ideal for the hospital planning implementation of early defibrillation to improve outcomes from cardiac arrest. This small and lightweight unit is the most versatile hospital defibrillation system available today. The PD 2000 is equally suited for general floor use by noncritical care BLS trained staff and ACLS code teams for defibrillation, external pacing and transport. New state-of-the-art modular AC power and rapid battery recharging allow the PD 2000 to meet the needs of every hospital area. Its easily exchangeable low cost lead acid battery system provides unequaled crash-cart uptime and improved quality in device maintenance and readiness. No other unit provides a hospital with the inherent flexibility of the ZOLL PD 2000 Advisory Defibrillator/Pacemaker. Features :Innovative features :Large MonitorNon-fade monitor. ECG monitor.Strip recorder.AC power supply for stationary use. Specifications:PacemakerType: VVI demand; asynchronous (fixed rate)when used without ECG leads.Pulse Type: Rectilinear, constant current.Pulse Duration: 40 milliseconds.Pulse Amplitude: Variable to 140 mA.Pacing Rate: Variable from 30 to 180 PPM.Output Protection: Fully defibrillator-protected and isolated.Pacer On: Message display on monitor. Defibrillator :Waveform: Damped sinusoid.Output EnergyDelivered: Selectable at 2, 3, 5, 7, 10, 20, 30, 50, 100, 150, 200, 300, 360 joules.Charge Time: Less than 10 seconds.Delivered EnergyDisplay: CRT monitor displays delivered energy.Synchronized Mode: Synchronizes defibrillator pulse to patients R-wave. SYNC messagedisplayed on monitor. Marker on monitor and on recorder paper identifies R-wave.Internal Paddles: Output limited to 50 joules when internal paddles are connected. Discharge from paddles.Charge Controls: Control on apex paddle and front panel.Paddles: Standard paddles are anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles.Defibrillation Electrodes: Specifically designed ZOLL Multi- Function Electrodes used in anterior/anterior or anterior/posterior positions; packaged in pairs.Integral Defibrillator Tester: Integral circuitry allows complete test of defibrillator charge and discharge without removing paddles from storage wells.Identical circuitry allows complete test of unit configured with multifunction cable.Defib On: Message display on monitor. Monitor and DisplayPatient Connection: Via 3-lead ECG cable, paddles, and elec trodes. Selectable by front panel switch.Input Protection: Fully defibrillator-protected. Special circuit prevents distortion of ECG by pacer pulse.Bandwidth: .5 40 Hz (3dB) standard.Display Format: Nonfade, moving trace with freeze capabilityMonitor On: Message display on monitor.Screen Type: High-resolution CRT display.Screen Size: 5 inches diagonally (108 mm x 85 mm viewing area).Sweep Speed: 25 mm/sec.Viewing Time: 4 seconds.Heart Rate: Digital display on monitor 0 300 BPM.Pacer Output Current: Digital display on monitor 0 140 mA.ECG Lead Selection: Display on monitor.ECG Size: .5, 1, 2 cm/mV display on monitor.Alarm On/Off Status: Display on monitor. User selectableHigh (60 280 BPM)Low (20 100 BPM).ECG Lead Off: Message display on monitor.Pacer Electrode Off: Message display on monitor.Defibrillator Paddle Fault: Message display on monitor.Defibrillator Electrode Fault: Message display on monitor.Recorder Paper Out: Message display on monitor.Low Battery Voltage: Message display on monitor.
View Complete Details

Radiant Warmer

We are offering radiant warmers are innovatively designed for use in nursery, labour & delivery suits to provide quick & effective treatment for the newborn infants, who suffer extreme of heat loss. Easy to useas technology advanced, we have kept the warmer simple & easy to use with one touch controls.Focused heatingthe heater with reflector makes it easier to work with the baby by efficiently providing even heat distribution across the cradle and not into the surrounding environment.Servo control modeservo control is an electronic feedback system which functions as a thermostat to maintain a constant temperature at the site of skin probe by regulating the heat output of radiant warmer. Maintaining a constant abdominal skin temperature between 36.5 & 37.0c is the simplest way to provide a thermoneutral environment, minimizing the no. Of calories needed to maintain normal body temperature & reducing the risks of cold stress or overheating. Servo control is the only acceptable method of heat regulation for the infant cared for under a radiant warmer. air control modeair control is an electronic feedback system which functions as a thermostat to maintain a constant temperature of baby cradle by regulating the heat output of radiant warmer. It also acts as a watch dog as air over temperature cuts off heater even if the warmer is operating is servo mode. Manual modethe manual mode allows the warmer to be kept baby ready without nuisance alarms. When needed the warmer provides safe, powerful & controlled warming to restore the temperature drop experienced by the baby immediately after delivery. mechanical specificationseasy access of infant from all sides with thick acrylic collapsible side panelsacrylic baby tray with infants head up down facility & foam mattress.Provision for positioning x - ray cassette.
View Complete Details

Drager Evita Ventilator

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name D
We are offering drager evita ventilator. drager evita 2the evita 2 critical-care ventilator maintains high standards of ventilation therapy product descriptionspontaneous breathing strategyone of evita 2 s strengths is its implementation of our "room to breathe" concept. Spontaneous breathing reduces the risk of atelectasis and improves the ventilation/perfusion ratio by maintaining a higher functional residual capacity. Bipaptm*/pcv+, the universal mode for ventilation and weaning, gives a patient the freedom to breathe spontaneously at any time. Autoflow, the next step in volume-oriented ventilation, encourages spontaneous breathing in all volume modes and another option, automatic tube compensation (atc), gives a patient the feeling of virtual extubation by eliminating the work involved in breathing with a tracheal tube. the right mode for every patientsince an evita 2 can be used to ventilate neonatal, pediatric or adult patients, it is the ideal workhorse for everyday clinical routine. The wide range of patients covered also reduces the amount of staff training required and ensures a greater flexibility in the use of resources. two-in-one ventilationmask ventilation can assist the weaning process by reducing the reintubation rate or even preventing intubation in the first place. The option of mask ventilation (niv) adds to an evita 2 s versatility so an icu only requires one device for conventional and non-invasive ventilation. everything in viewthe evita 2 provides patient and ventilator-related monitoring with user interaction reduced to a minimum. The high-resolution full-color screen displays comprehensive information on a patients status, always showing two ventilation curves and six monitored values, and the screen configuration can be customized to show the most important values for a particular icu. one knob, simplified settingsthis ventilator has a clearly arranged front panel consisting of a monitoring screen and various setting soft keys. The rotary knob plays a key role. The active setting parameters are visible at a glance and changes can be made by the well-established select-adjust-confirm principle. ventilation at a glancethe principle of only showing the necessary parameters reduces the complexity of everyday monitoring. Additional functions are located in the various screen menus. The ventilator provides you with a full-text message in the event of alarms so you have a clear idea of the problem. simpler and speedier standard proceduresthe evita 2 contains numerous functions to speed up and simplify routine procedures. Start-up settings can be configured to specific icu practices. Suction procedures are simplified with the touch of a button, the exhalation valve can be changed in seconds to minimize downtime and sensors are automatically calibrated daily. However, manual calibration is also possible without interruption to ventilation. All these functions assist in reducing time for standard procedures. technical specificationsventilation settingsventilation mode- ippv, ippvassist (cmv, cmvassist)- simv, simvasb (simv, simv/psupp)- mmv, mmvasb (mmv, mmv/psupp)- bipap1), bipap1)asb, bipap1)assist (pcv+, pcv+/psupp, pcv+assist)- cpap, cpapasb (cpap, cpap/psupp)- aprv (optional)- ilv (optional) enhancements - autoflowtm automatic adaptation of inspiratory flow in volume controlled modes- atctm automatic tube compensation (optional)- niv - mask ventilation (optional) ventilation frequency (f): 0 to 100 /min, 0 to150 /min (neonatal) inspiration time (tinsp): 0.1 to 10 s tidal volume (vt) (btps):- 0.1 to 2.0 l (adult)- 0.02 to 0.3 l (pediatric)- 0.003 to 0.1 l (neonatal) inspiratory flow:- 6 to 120 l/min (adult)- 6 to 30 l/min (pediatric and neonatal)inspiratory pressure: 0 to 80 mbar (cmh2o) peep / intermittent peep: 0 to 35 mbar (cmh2o) pressureassist (pasb) (psupp): 0 to 80 mbar (cmh2o)rise time for inspiratory pressure: 0 to 2 s o2 concentration: 21 to 100 vol.% multi-sense trigger criteria: internal automatic pressure trigger, flow, volume (flow adjustable 0.3 to 15 l/min) measured values displayedairway pressure: peak pressure, plateau pressure, mean pressure, peep, min. Pressure (0 to 99 mbar/cmh2o)minute volume (mv), (btps): mv, mvspont, mvleak (0 to 99 l/min)tidal volume (vt), (btps): inspired vt, expired vt, vtasb (vtps) (0 to 3999 ml)breathing frequency (f): ftotal, fspon, fmand. (0 to 300/bpm)o2 concentration: (fio2) inspired o2 concentration (15 to 100 vol.%)lung mechanics:- resistance ((0.0 to 600 mbar/l/s)(cmh2o/l/s)- compliance ((0.0 to 300 ml/mbar)(ml/cmh2o)breathing gas temperature: 18to 51cwaveforms: airway pressure-time, flow-time, volume-time, . trends (optional): fio2, mv, vt, f, peepi, r, c, etco2, . loops (optional): paw-v, v-flow, flow-paw, . capnography (etco2) (optional): 0 to 100 mmhgco2 production (vco2): 0 to 999 ml/min, stpdserial dead space vds: 0 to 999 ml, btpsdead space ventilation (vds/vt): 0 to 99% alarms / monitoringairway pressure: high/lowexpired minute volume: high/lowtidal volume: highapnea alarm time: 5 to 60 sspontaneous breath frequency: highinspired o2 concentration: high/lowbreathing gas temperature: highspo2 pulse (optional): high/lowetco2 (optional): high/low performance datamax. Flow for pressure support and spontaneous breathing: 180 l/min (adult), 60 l/min (pediatric)valve response time: 5 mscontrol principle: time cycled, volume constant, pressure-controlledsafety relief valve: 100 mbar (cmh2o)leakage compensationhose system compensationoutlet for pneumatic nebulizer operating datamains power connection: 100 to 240 v, 50/60 hz, 10 to 30 v dc (optional)power consumption: approx. 125 wgas supply operating pressure: o2, air: 2.7 to 6 bar/39 to 87 psi physical specificationsdimensions ventilator (wxhxd): 530x290x450 cm (20.9x11.4x17.7 inches) (without trolley)weight basic unit: approx. 27 kg (60 lbs.)diagonal screen size: 6.5" tft lcd color display machine outputsdigital output: output and reception via an rs 232 c interfacedigital output (optional): for output and reception via two rs 232 c interfacesanalog output (optional): for analog output of two measured values
View Complete Details

Drager Ventilator

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Drager
Drager oxylog 1000the oxylog 1000 offers first aid ventilation of patients in emergency situations. Designed to be used outdoors, its intuitive operation, robustness and transportability make the oxylog 1000 complete in its class. The ventilator has integrated audible and visual alarms that monitor both the airway pressure and supply pressure to aid in patient safety. all functions are pneumatically operated, so the ventilator does not depend on any electrical power source. Thanks to its fundamental design, the oxylog 1000 also stands for great reliability, ready to meet rough conditions during your mission. technical data oxylog 1000 a time-cycled, volume controlled and pressure limited emergency ventilator for the controlled ventilationof patients who require a minute volume of at least 3 l/min. dimensions (w x h x d) 215 x 90 x 215 mm / 8.5 x 3.5 x 8.5 inches (excl. Handle)weight 3.15 kg / 7.3 lbs drive gasmedical grade o2 or in exceptional cases compressed airsupply pressure 2.7 to 6 bar / 40 to 88 psi at 60 l/min performance dataventilation mode ippv/ cmvpeep ventilation with optional peep valveprinciple of operation flow choppercontrol time-cycled, volume-constantventilation frequency, smoothly variable 4 to 54 1/minminute volume, smoothly variable 3 to 20 l/mini:e ratio (fixed) 1 :1.5max.airway pressure (pmax), smoothly variable 25 to 60 mbar / cm h2o o2 concentration of ventilation gas when o2 drivenswitch to air mix approx 60% by vol. O2switch to no air mix 100% by vol. O2gas consumption of control approx 1.0 l/mindead space volume approx 12 mldevice compliance approx. 1 ml/mbar / cm h2osafety valve opening pressure 80 mbar / cm h2opressure gauge display 10 to + 80 mbar / cm h2o alarm functionssupply pressure low (psupply) supply pressure drops below 2.7 bar / 40 psiairway pressure high (paw high) actual value exceeds set value (pmax)airway pressure low (paw low) a pressure of 10 mbar/cm h2o is not exceeded during inspirationthe alarms are both visual and audible. they are provided by purely pneumatic components and do not require any power supply. conditions for operationtemperature range 18 c to +50 c / 0 to 122 frelative humidity 15% to 95% rel humidityambient pressure 700 to 1100 h pavibration tested in acc.with mil std 810 f, methode 514.5airworthiness in acc.with rtca do-160 d, section 8classification acc. To ec directive 93/42/eec class iibumdns code 18-098typical operating time mv = 10 l/min2.5 l cylinder / 200 bar: approx. 90 min for "air mix", approx. 45 min for "no air mix"e-type o2 cylinder: approx. 112 min for "air mix", approx. 56 min for "no air mix"d-type o2 cylinder: approx. 64 min for "air mix", approx. 32 min for "no air mix".
View Complete Details

Hp Code Master Defibrillator

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name HP
We are offering hp code master defibrillator. hp code master defibrillator. We offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are: hp code master defibrillator the hp code master we offer are defibrillator, which are available in professionally refurbished with a built-in recorder, ecg, pacing and ac power with battery back-up. These are available with many functionalities. features :dimensions : 7.9"h x 11.8"w x 15.6"l, 20cm x 30cm x 39.7cmweight: 24 lbs. / 10.9kg battery :type: rechargeable, sealed lead-acid battery. 4 ah, 12 v nominal. charge time: 2 hours to 90% of full capacity. 18 hours to 100% capacity. Repeated charging to less than 100% will reduce the useful life of the battery. capacity: 2.5 hours monitoring or 50 full-energy discharges or 1 hour monitoring and recording. ac input: 100 to 230 vac +/- 15%, 50/60 hz. battery indicators: illuminated led indicates battery is charging. Low battery message appears on the monitor. synchronizer :sync message appears on the monitor and is annotated periodically on the recorder while in synchronous mode. An audible beep sounds with each detected r-wave; while a marker on the monitor and sync mark on the recorder strip indicate the discharge point. Paddles: standard paddles are anterior / anterior. Adult electrodes (83 cm sq) slide off to expose pediatric electrodes (21 cm sq). Paddle cord is 10 feet (3m). Full range of internal paddles are available. monitor :input: ecg activity may be viewed through the paddles or patient cable. Lead fault: leads off message and dashed baseline appear on the monitor if a lead becomes disconnected. Common mode rejection: greater than 100db measured as per aami standards for cardiac monitors. Heart rate display: digital read out on monitor from 20 to 280 bpm.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • S. B. Nain (Meditech Electronics)
  • Meditech Electronics Rnrnrnj-81, Sec-4, Dsiidc Indl. Area Rnrnbawana, New Delhi 110039rnrn Rntel +91-11-27762484 Mob:+919868165949meditech Electronics
  • Share us via
  • Call 08068051309 Ext. 250
Retailer of Surgical Equipment & Supplies from Delhi, Delhi by Meditech Electronics
Post Buy Requirement
ME
Delhi, India
Verified Add Review

Our Products

  1. LED Lights 5 Products available
  2. Medical Equipment & Supplies 4 Products available
  3. Computer Monitor 8 Products available
  4. Surgical Equipment & Supplies 7 Products available
  5. Medical Ventilators 3 Products available
  6. ECG Machine 4 Products available
  7. Pulse Oximeters 3 Products available
  8. Others 19 Products available

Surgical Equipment & Supplies #131325

Physio Control Life Pack 9 Defibrillator

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Life Pack
We are offering physio control life pack 9 defibrillator. physio control defibrillator. we offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are: physio control defibrillator we offer defibrillator physio control monitor, which is designed to meet the needs of clinical, biomedical engineering, and purchasing professionals throughout the world. This units simple 1-2-3 operation and user-friendly display, plus its compact, portable, space-saving design, revolutionized in-hospital de fibrillation. simple, logical controlsuser-friendly displayscode summarycritical event recordspace savingvertical designoptional shockadvisory system innovative features :high and low energyselect displaysannotating recorderauxiliary paddles for hands-free de fibrillation. designed for ease of maintenancediagnostics for simple test and calibration
View Complete Details

Defibrillator

  • Min. Order (MOQ) 1 Piece(s)
Zoll pd 1200we offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are: zoll pd1200 the zoll pd 1200, combining defibrillation, pacing, and monitoring, offers complete acls-response capabilities in a single, easy-to-use unit that is ideal for critical and specialitycare areas. It can be configured with the zoll "hands-off" multi-function electrodes, with standard defibrillation paddles and pacing electrodes, and with internal defibrillation paddles and pacing electrodes. The zoll pd 1200 operates on both ac line and battery power and is completely compatible with all models in thezoll cardiac resuscitation system. features :innovative features :large monitornon-fade monitor. ecg monitor. strip recorder. ac power supply for stationary use. specifications:pacemakertype: vvi demand; asynchronous (fixed rate)when used without ecg leads. pulse type: rectilinear, constant current. pulse duration: 40 milliseconds. pulse amplitude: variable to 140 ma. pacing rate: variable from 30 to 180 ppm. output protection: fully defibrillator-protected and isolated. pacer on: message display on monitor. defibrillator :waveform: damped sinusoid. output energydelivered: selectable at 2, 3, 5, 7, 10, 20, 30, 50, 100, 150, 200, 300, 360 joules. charge time: less than 10 seconds. delivered energydisplay: crt monitor displays delivered energy. synchronized mode: synchronizes defibrillator pulse to patients r-wave. sync messagedisplayed on monitor. Marker on monitor and on recorder paper identifies r-wave. internal paddles: output limited to 50 joules when internal paddles are connected. Discharge from paddles. charge controls: control on apex paddle and front panel. paddles: standard paddles are anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles. defibrillation electrodes: specifically designed zoll multi- function electrodes used in anterior/anterior or anterior/posterior positions; packaged in pairs. integral defibrillator tester: integral circuitry allows complete test of defibrillator charge and discharge without removing paddles from storage wells. identical circuitry allows complete test of unit configured with multifunction cable. defib on: message display on monitor. monitor and displaypatient connection: via 3-lead ecg cable, paddles, and elec trodes. Selectable by front panel switch. input protection: fully defibrillator-protected. Special circuit prevents distortion of ecg by pacer pulse. bandwidth: .5 40 hz (3db) standard. display format: nonfade, moving trace with freeze capabilitymonitor on: message display on monitor. screen type: high-resolution crt display. screen size: 5 inches diagonally (108 mm x 85 mm viewing area). sweep speed: 25 mm/sec. viewing time: 4 seconds. heart rate: digital display on monitor 0 300 bpm. pacer output current: digital display on monitor 0 140 ma. ecg lead selection: display on monitor. ecg size: .5, 1, 2 cm/mv display on monitor. alarm on/off status: display on monitor. User selectablehigh (60 280 bpm)low (20 100 bpm). ecg lead off: message display on monitor. pacer electrode off: message display on monitor. defibrillator paddle fault: message display on monitor. defibrillator electrode fault: message display on monitor. recorder paper out: message display on monitor. low battery voltage: message display on monitor.
View Complete Details

Defibrillator

  • Min. Order (MOQ) 1 Piece(s)
OLL PD 2000We offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are: Zoll PD 2000 The ZOLL PD 2000 Advisory Defibrillator/Pacemaker is the first device designed as a completely integrated system for early defibrillation and advanced cardiac life support in the hospital. The built-in ventricular fibrillation detection system eliminates adapters and a "paddlefree" electrode system is easily applied to speed shockdelivery and external pacing. Standardized controls make it ideal for the hospital planning implementation of early defibrillation to improve outcomes from cardiac arrest. This small and lightweight unit is the most versatile hospital defibrillation system available today. The PD 2000 is equally suited for general floor use by noncritical care BLS trained staff and ACLS code teams for defibrillation, external pacing and transport. New state-of-the-art modular AC power and rapid battery recharging allow the PD 2000 to meet the needs of every hospital area. Its easily exchangeable low cost lead acid battery system provides unequaled crash-cart uptime and improved quality in device maintenance and readiness. No other unit provides a hospital with the inherent flexibility of the ZOLL PD 2000 Advisory Defibrillator/Pacemaker. Features :Innovative features :Large MonitorNon-fade monitor. ECG monitor.Strip recorder.AC power supply for stationary use. Specifications:PacemakerType: VVI demand; asynchronous (fixed rate)when used without ECG leads.Pulse Type: Rectilinear, constant current.Pulse Duration: 40 milliseconds.Pulse Amplitude: Variable to 140 mA.Pacing Rate: Variable from 30 to 180 PPM.Output Protection: Fully defibrillator-protected and isolated.Pacer On: Message display on monitor. Defibrillator :Waveform: Damped sinusoid.Output EnergyDelivered: Selectable at 2, 3, 5, 7, 10, 20, 30, 50, 100, 150, 200, 300, 360 joules.Charge Time: Less than 10 seconds.Delivered EnergyDisplay: CRT monitor displays delivered energy.Synchronized Mode: Synchronizes defibrillator pulse to patients R-wave. SYNC messagedisplayed on monitor. Marker on monitor and on recorder paper identifies R-wave.Internal Paddles: Output limited to 50 joules when internal paddles are connected. Discharge from paddles.Charge Controls: Control on apex paddle and front panel.Paddles: Standard paddles are anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles.Defibrillation Electrodes: Specifically designed ZOLL Multi- Function Electrodes used in anterior/anterior or anterior/posterior positions; packaged in pairs.Integral Defibrillator Tester: Integral circuitry allows complete test of defibrillator charge and discharge without removing paddles from storage wells.Identical circuitry allows complete test of unit configured with multifunction cable.Defib On: Message display on monitor. Monitor and DisplayPatient Connection: Via 3-lead ECG cable, paddles, and elec trodes. Selectable by front panel switch.Input Protection: Fully defibrillator-protected. Special circuit prevents distortion of ECG by pacer pulse.Bandwidth: .5 40 Hz (3dB) standard.Display Format: Nonfade, moving trace with freeze capabilityMonitor On: Message display on monitor.Screen Type: High-resolution CRT display.Screen Size: 5 inches diagonally (108 mm x 85 mm viewing area).Sweep Speed: 25 mm/sec.Viewing Time: 4 seconds.Heart Rate: Digital display on monitor 0 300 BPM.Pacer Output Current: Digital display on monitor 0 140 mA.ECG Lead Selection: Display on monitor.ECG Size: .5, 1, 2 cm/mV display on monitor.Alarm On/Off Status: Display on monitor. User selectableHigh (60 280 BPM)Low (20 100 BPM).ECG Lead Off: Message display on monitor.Pacer Electrode Off: Message display on monitor.Defibrillator Paddle Fault: Message display on monitor.Defibrillator Electrode Fault: Message display on monitor.Recorder Paper Out: Message display on monitor.Low Battery Voltage: Message display on monitor.
View Complete Details

Radiant Warmer

We are offering radiant warmers are innovatively designed for use in nursery, labour & delivery suits to provide quick & effective treatment for the newborn infants, who suffer extreme of heat loss. Easy to useas technology advanced, we have kept the warmer simple & easy to use with one touch controls.Focused heatingthe heater with reflector makes it easier to work with the baby by efficiently providing even heat distribution across the cradle and not into the surrounding environment.Servo control modeservo control is an electronic feedback system which functions as a thermostat to maintain a constant temperature at the site of skin probe by regulating the heat output of radiant warmer. Maintaining a constant abdominal skin temperature between 36.5 & 37.0c is the simplest way to provide a thermoneutral environment, minimizing the no. Of calories needed to maintain normal body temperature & reducing the risks of cold stress or overheating. Servo control is the only acceptable method of heat regulation for the infant cared for under a radiant warmer. air control modeair control is an electronic feedback system which functions as a thermostat to maintain a constant temperature of baby cradle by regulating the heat output of radiant warmer. It also acts as a watch dog as air over temperature cuts off heater even if the warmer is operating is servo mode. Manual modethe manual mode allows the warmer to be kept baby ready without nuisance alarms. When needed the warmer provides safe, powerful & controlled warming to restore the temperature drop experienced by the baby immediately after delivery. mechanical specificationseasy access of infant from all sides with thick acrylic collapsible side panelsacrylic baby tray with infants head up down facility & foam mattress.Provision for positioning x - ray cassette.
View Complete Details

Drager Evita Ventilator

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name D
We are offering drager evita ventilator. drager evita 2the evita 2 critical-care ventilator maintains high standards of ventilation therapy product descriptionspontaneous breathing strategyone of evita 2 s strengths is its implementation of our "room to breathe" concept. Spontaneous breathing reduces the risk of atelectasis and improves the ventilation/perfusion ratio by maintaining a higher functional residual capacity. Bipaptm*/pcv+, the universal mode for ventilation and weaning, gives a patient the freedom to breathe spontaneously at any time. Autoflow, the next step in volume-oriented ventilation, encourages spontaneous breathing in all volume modes and another option, automatic tube compensation (atc), gives a patient the feeling of virtual extubation by eliminating the work involved in breathing with a tracheal tube. the right mode for every patientsince an evita 2 can be used to ventilate neonatal, pediatric or adult patients, it is the ideal workhorse for everyday clinical routine. The wide range of patients covered also reduces the amount of staff training required and ensures a greater flexibility in the use of resources. two-in-one ventilationmask ventilation can assist the weaning process by reducing the reintubation rate or even preventing intubation in the first place. The option of mask ventilation (niv) adds to an evita 2 s versatility so an icu only requires one device for conventional and non-invasive ventilation. everything in viewthe evita 2 provides patient and ventilator-related monitoring with user interaction reduced to a minimum. The high-resolution full-color screen displays comprehensive information on a patients status, always showing two ventilation curves and six monitored values, and the screen configuration can be customized to show the most important values for a particular icu. one knob, simplified settingsthis ventilator has a clearly arranged front panel consisting of a monitoring screen and various setting soft keys. The rotary knob plays a key role. The active setting parameters are visible at a glance and changes can be made by the well-established select-adjust-confirm principle. ventilation at a glancethe principle of only showing the necessary parameters reduces the complexity of everyday monitoring. Additional functions are located in the various screen menus. The ventilator provides you with a full-text message in the event of alarms so you have a clear idea of the problem. simpler and speedier standard proceduresthe evita 2 contains numerous functions to speed up and simplify routine procedures. Start-up settings can be configured to specific icu practices. Suction procedures are simplified with the touch of a button, the exhalation valve can be changed in seconds to minimize downtime and sensors are automatically calibrated daily. However, manual calibration is also possible without interruption to ventilation. All these functions assist in reducing time for standard procedures. technical specificationsventilation settingsventilation mode- ippv, ippvassist (cmv, cmvassist)- simv, simvasb (simv, simv/psupp)- mmv, mmvasb (mmv, mmv/psupp)- bipap1), bipap1)asb, bipap1)assist (pcv+, pcv+/psupp, pcv+assist)- cpap, cpapasb (cpap, cpap/psupp)- aprv (optional)- ilv (optional) enhancements - autoflowtm automatic adaptation of inspiratory flow in volume controlled modes- atctm automatic tube compensation (optional)- niv - mask ventilation (optional) ventilation frequency (f): 0 to 100 /min, 0 to150 /min (neonatal) inspiration time (tinsp): 0.1 to 10 s tidal volume (vt) (btps):- 0.1 to 2.0 l (adult)- 0.02 to 0.3 l (pediatric)- 0.003 to 0.1 l (neonatal) inspiratory flow:- 6 to 120 l/min (adult)- 6 to 30 l/min (pediatric and neonatal)inspiratory pressure: 0 to 80 mbar (cmh2o) peep / intermittent peep: 0 to 35 mbar (cmh2o) pressureassist (pasb) (psupp): 0 to 80 mbar (cmh2o)rise time for inspiratory pressure: 0 to 2 s o2 concentration: 21 to 100 vol.% multi-sense trigger criteria: internal automatic pressure trigger, flow, volume (flow adjustable 0.3 to 15 l/min) measured values displayedairway pressure: peak pressure, plateau pressure, mean pressure, peep, min. Pressure (0 to 99 mbar/cmh2o)minute volume (mv), (btps): mv, mvspont, mvleak (0 to 99 l/min)tidal volume (vt), (btps): inspired vt, expired vt, vtasb (vtps) (0 to 3999 ml)breathing frequency (f): ftotal, fspon, fmand. (0 to 300/bpm)o2 concentration: (fio2) inspired o2 concentration (15 to 100 vol.%)lung mechanics:- resistance ((0.0 to 600 mbar/l/s)(cmh2o/l/s)- compliance ((0.0 to 300 ml/mbar)(ml/cmh2o)breathing gas temperature: 18to 51cwaveforms: airway pressure-time, flow-time, volume-time, . trends (optional): fio2, mv, vt, f, peepi, r, c, etco2, . loops (optional): paw-v, v-flow, flow-paw, . capnography (etco2) (optional): 0 to 100 mmhgco2 production (vco2): 0 to 999 ml/min, stpdserial dead space vds: 0 to 999 ml, btpsdead space ventilation (vds/vt): 0 to 99% alarms / monitoringairway pressure: high/lowexpired minute volume: high/lowtidal volume: highapnea alarm time: 5 to 60 sspontaneous breath frequency: highinspired o2 concentration: high/lowbreathing gas temperature: highspo2 pulse (optional): high/lowetco2 (optional): high/low performance datamax. Flow for pressure support and spontaneous breathing: 180 l/min (adult), 60 l/min (pediatric)valve response time: 5 mscontrol principle: time cycled, volume constant, pressure-controlledsafety relief valve: 100 mbar (cmh2o)leakage compensationhose system compensationoutlet for pneumatic nebulizer operating datamains power connection: 100 to 240 v, 50/60 hz, 10 to 30 v dc (optional)power consumption: approx. 125 wgas supply operating pressure: o2, air: 2.7 to 6 bar/39 to 87 psi physical specificationsdimensions ventilator (wxhxd): 530x290x450 cm (20.9x11.4x17.7 inches) (without trolley)weight basic unit: approx. 27 kg (60 lbs.)diagonal screen size: 6.5" tft lcd color display machine outputsdigital output: output and reception via an rs 232 c interfacedigital output (optional): for output and reception via two rs 232 c interfacesanalog output (optional): for analog output of two measured values
View Complete Details

Drager Ventilator

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name Drager
Drager oxylog 1000the oxylog 1000 offers first aid ventilation of patients in emergency situations. Designed to be used outdoors, its intuitive operation, robustness and transportability make the oxylog 1000 complete in its class. The ventilator has integrated audible and visual alarms that monitor both the airway pressure and supply pressure to aid in patient safety. all functions are pneumatically operated, so the ventilator does not depend on any electrical power source. Thanks to its fundamental design, the oxylog 1000 also stands for great reliability, ready to meet rough conditions during your mission. technical data oxylog 1000 a time-cycled, volume controlled and pressure limited emergency ventilator for the controlled ventilationof patients who require a minute volume of at least 3 l/min. dimensions (w x h x d) 215 x 90 x 215 mm / 8.5 x 3.5 x 8.5 inches (excl. Handle)weight 3.15 kg / 7.3 lbs drive gasmedical grade o2 or in exceptional cases compressed airsupply pressure 2.7 to 6 bar / 40 to 88 psi at 60 l/min performance dataventilation mode ippv/ cmvpeep ventilation with optional peep valveprinciple of operation flow choppercontrol time-cycled, volume-constantventilation frequency, smoothly variable 4 to 54 1/minminute volume, smoothly variable 3 to 20 l/mini:e ratio (fixed) 1 :1.5max.airway pressure (pmax), smoothly variable 25 to 60 mbar / cm h2o o2 concentration of ventilation gas when o2 drivenswitch to air mix approx 60% by vol. O2switch to no air mix 100% by vol. O2gas consumption of control approx 1.0 l/mindead space volume approx 12 mldevice compliance approx. 1 ml/mbar / cm h2osafety valve opening pressure 80 mbar / cm h2opressure gauge display 10 to + 80 mbar / cm h2o alarm functionssupply pressure low (psupply) supply pressure drops below 2.7 bar / 40 psiairway pressure high (paw high) actual value exceeds set value (pmax)airway pressure low (paw low) a pressure of 10 mbar/cm h2o is not exceeded during inspirationthe alarms are both visual and audible. they are provided by purely pneumatic components and do not require any power supply. conditions for operationtemperature range 18 c to +50 c / 0 to 122 frelative humidity 15% to 95% rel humidityambient pressure 700 to 1100 h pavibration tested in acc.with mil std 810 f, methode 514.5airworthiness in acc.with rtca do-160 d, section 8classification acc. To ec directive 93/42/eec class iibumdns code 18-098typical operating time mv = 10 l/min2.5 l cylinder / 200 bar: approx. 90 min for "air mix", approx. 45 min for "no air mix"e-type o2 cylinder: approx. 112 min for "air mix", approx. 56 min for "no air mix"d-type o2 cylinder: approx. 64 min for "air mix", approx. 32 min for "no air mix".
View Complete Details

Hp Code Master Defibrillator

  • Min. Order (MOQ) 1 Piece(s)
  • Brand Name HP
We are offering hp code master defibrillator. hp code master defibrillator. We offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are: hp code master defibrillator the hp code master we offer are defibrillator, which are available in professionally refurbished with a built-in recorder, ecg, pacing and ac power with battery back-up. These are available with many functionalities. features :dimensions : 7.9"h x 11.8"w x 15.6"l, 20cm x 30cm x 39.7cmweight: 24 lbs. / 10.9kg battery :type: rechargeable, sealed lead-acid battery. 4 ah, 12 v nominal. charge time: 2 hours to 90% of full capacity. 18 hours to 100% capacity. Repeated charging to less than 100% will reduce the useful life of the battery. capacity: 2.5 hours monitoring or 50 full-energy discharges or 1 hour monitoring and recording. ac input: 100 to 230 vac +/- 15%, 50/60 hz. battery indicators: illuminated led indicates battery is charging. Low battery message appears on the monitor. synchronizer :sync message appears on the monitor and is annotated periodically on the recorder while in synchronous mode. An audible beep sounds with each detected r-wave; while a marker on the monitor and sync mark on the recorder strip indicate the discharge point. Paddles: standard paddles are anterior / anterior. Adult electrodes (83 cm sq) slide off to expose pediatric electrodes (21 cm sq). Paddle cord is 10 feet (3m). Full range of internal paddles are available. monitor :input: ecg activity may be viewed through the paddles or patient cable. Lead fault: leads off message and dashed baseline appear on the monitor if a lead becomes disconnected. Common mode rejection: greater than 100db measured as per aami standards for cardiac monitors. Heart rate display: digital read out on monitor from 20 to 280 bpm.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • S. B. Nain (Meditech Electronics)
  • Meditech Electronics Rnrnrnj-81, Sec-4, Dsiidc Indl. Area Rnrnbawana, New Delhi 110039rnrn Rntel +91-11-27762484 Mob:+919868165949meditech Electronics
  • Share us via
  • Call 08068051309 Ext. 250