-
Min. Order (MOQ)
1 Piece(s)
-
Brand Name
Drager
We are ofering drager savina ventilator. Technical data savinaventilation modes ippv (cmv), ippvassist (cmvassist)simv, simvasb (simv/ps)cpap, cpapasb (cpap/ps)bipap1), (pcv+) (optional), bipap1)asb (pcv+/ps) (optional)enhancements niv non invasive ventilation with optimized alarm system and automatic leakage compensation (optional)autoflow automatic adaptation of the inspiratory flow in volumeorientated ventilation modes (optional). lpo - low pressure oxygen. Independant oxygen supply, e.g. With an o2 concentrator (optional)graphic screen - advanced ventilation monitoring (optional), nurse call - connection for transmitting alarm signals to a centralpatient type adult, pediatricventilation frequency 2 to 80 bpminspiration time 0.2 to10 stidal volume 0.05 to 2.0 l, btps2)inspiratory flow 0 to180 l/mininspiratory pressure 0 to 99 mbar 3) (cmh2o)peep/interm. Peep 0 to 35 mbar (cmh2o)pressure support/asb 0 to 35 mbar (cmh2o) (relative to peep)flow acceleration 5 to 200 mbar/s (cmh2o/s)o2-concentration 21 to100 vol. %trigger sensitivity 1 to15 l/minmeasured value displayairway pressure peak pressure, plateau pressure, mean airway pressure, measurements peep 0 -100 mbar (cmh2o)minute volume (mv) total mv, spontaneous mv 0 to 99 l/min, btpstidal volume vt inspiratory vt, expiratory vt 0 to 3999 ml, btpsbreathing frequency total and spontaneous breathing frequency, 0 -150 bpminspiratory o2-concentration 21 to100 vol. %breathing gas temperature 18 to 48 c (sensor optional)curve displays airway pressure / time, flow / timeventilation ratio (i:e) 150:1 to 1:150alarmsairway pressures high / lowexpiratory minute volume high / lowtidal volume high / lowapnea-alarm time 15 to 60 secspontaneous breathing frequency highinspiratory o2-concentration high / lowinspiratory breathing gas temperature highperformance datamaximum flow for pressure assist/spontaneous breathing 180 l/minvalve response time t090 5 mscontrol principle time-cycled, volume-constant, pressure- controlledsafety valve opening pressure 100 mbar (cmh2o)emergency valve automatically enables spontaneous breathing with filtered ambientair if air o2and o2 supply should fail. automatic gas switch-over function if supply failsoutput for pneumatic medicament nebulizer synchronized with inspiration operating datamain power connection 100 v to 240 v, 50/60 hz ac, 10 to 36 v dctypical power consumption 100 winternal battery approx. 60 min (optional extension up to 7 h)digital machine outputsdigital output and input via an rs 232 c interface, drger medibus standardgas supplyair turbine technologyo2 gas supply 3 bar (39 psi) to 10 % up to 6 bar (87 psi). dimensions and weightsdimensions w x h x d (without trolley) 380 x 383 x 358 mm (15.0 x 156.1 x 14.1 inches)weight (basic device) approx. 24 kg (53 lbs.)diagonal screen size 6.1" tft color screenbipap trademark used under licencebtps body temperature pressure saturated. Measured values relating to the conditions of the patient lung, body temperature 37 c, steam-saturated gas, ambient pressure. 3) 1 mbar = 100 pa, autoflow, trademark by drge