My ExportersIndia

For Buyer

For Seller

For Help

Our Products

  1. Orthopedic Trauma Implants 79 Products available
  2. Beds 23 Products available
  3. Living Room And Plastic Furniture 13 Products available
  4. Screws 12 Products available
  5. Tables 11 Products available
  6. Orthopedic Equipment & Supplies 10 Products available
  7. Trolleys 9 Products available
  8. Rehabilitation Equipment 8 Products available
  9. Hip Prosthesis 8 Products available
  10. Physiotherapy Products & Equipment 5 Products available
  11. Surgical Equipment & Supplies 5 Products available
  12. Laboratory Apparatus 4 Products available
  13. Medical Equipment & Supplies 4 Products available
  14. Laboratory Equipments 4 Products available
  15. Industrial & Engineering Products 3 Products available
  16. Pipe Caps 3 Products available
  17. Hanging Hooks 3 Products available
  18. Hospital Equipment 3 Products available
  19. Child & Baby Care Products 3 Products available
  20. Sterilizers 3 Products available
  21. Institutional Furniture 3 Products available
  22. Cabinets & Enclosures 3 Products available
  23. Rulers 2 Products available
  24. Hospital & Medical Lights 2 Products available
  25. Suction Machines 2 Products available
  26. Medical & Hospital Furniture 2 Products available
  27. Office And Commercial Furniture 2 Products available
  28. Rubber Products 2 Products available
  29. Wheelchairs 2 Products available
  30. Ladies Tops 2 Products available
  31. Orthopedic Implant 2 Products available
  32. Traction Equipment 2 Products available
  33. Wires 2 Products available
  34. Belts 2 Products available
  35. Serving Plate 2 Products available
  36. Nuts Bolts And Fasteners 2 Products available
  37. Funnel Set 1 Products available
  38. Surgical Needles & Scissors 1 Products available
  39. Dental Treatment Service 1 Products available
  40. Weighing Machine 1 Products available
  41. Garden & Outdoor Furniture 1 Products available
  42. Hospital Lights 1 Products available
  43. Spoon 1 Products available
  44. Hospital Bed Sheet 1 Products available
  45. Hospital & Surgical Clothes 1 Products available
  46. Storage Drawer 1 Products available
  47. Files, Folders & Notebooks 1 Products available
  48. Cushions 1 Products available
  49. Emergency Medical Equipment 1 Products available
  50. Pumps, Pumping Machines & Parts 1 Products available
  51. Power Saws 1 Products available
  52. Health Care Products 1 Products available
  53. Dustbin 1 Products available
  54. Shoes 1 Products available
  55. Disposable Crockery & Cutlery 1 Products available
  56. Storage Drums, Tanks & Containers 1 Products available
  57. Nail Set 1 Products available
  58. Mattress 1 Products available
  59. Street Lights 1 Products available
  60. Steel & Steel Products 1 Products available
  61. Footwear Accessories 1 Products available
  62. Baby Cradle 1 Products available
  63. Cupboard 1 Products available
  64. Metal & Metal Products 1 Products available
  65. Face Mask 1 Products available
  66. Machines And Equipments 1 Products available
  67. Lamps 1 Products available
  68. Backrest 1 Products available
  69. Autoclaves 1 Products available
  70. Power Tools 1 Products available
  71. Dressing Bandages & Disposables 1 Products available
  72. Buckets 1 Products available
  73. Barrels 1 Products available
  74. Metal Beds 1 Products available
  75. Pillows 1 Products available
  76. Weighing Scale 1 Products available
  77. Weighing Scales & Measuring Tapes 1 Products available
  78. Eyelet 1 Products available
  79. Hospital Cabinet 1 Products available
  80. Others Products 102 Products available

Our Products

We are leaders in the market for providing best range of Tens Nail, Small Fragment - Proximal Humerus Safety Lock Plate 3.5, Small Fragment - Distal Humerus Safety Lock Plate 2.7/3.5, Dorsolateral, Small Fragment - Distal Humerus Safety Lock Plate 3.5, Extra-Articular and Small Fragment - Medial Distal Humerus Safety Lock Plate 2.7/3.5

Ambu Type Bags

Artificial Resuscitator (Ambu Type Bag), Silicone (green), Adult, Autoclavable: Ambu Type Bag Capacity 1600ml.With translucent face mask size: 4.100% latex free. CE certified.
View Complete Details

Tens Nail

  • TENS Nail - Length 40cm are intended for Diaphyseal and certain Metaphyseal fractures of long bones, Subcapital Humerus, Metatarsal and Metacarpal fractures and complex Clavicular fractures in Children.
  • In adult patients TENS Nail is used for the Diaphyseal fractures of long bones in upper extremity and Clavicle Shaft fractures.
  • Use with Instrument Set - AS149
  • Extn. in mm STAINLESS STEEL
    Lenght 40cm Lenght 44cm
    1.5 TEN1.5-40 -
    2.0 TEN2-40 TEN2-44
    2.5 TEN2.5-40 TEN2.5-44
    3.0 TEN3-40 TEN3-44
    3.5 TEN3.5-40 TEN3.5-44
    4.0 TEN4-40 TEN4-44
    4.5 TEN4.5-40

    TEN4.5-44

  • Dia in mm TITANIUM
    Lenght 40cm Lenght 44cm
    1.5 Ti-TEN1.5-40 -
    2.0 Ti-TEN2-40 Ti-TEN2-44
    2.5 Ti-TEN2.5-40 Ti-TEN2.5-44
    3.0 Ti-TEN3-40 Ti-TEN3-44
    3.5 Ti-TEN3.5-40 Ti-TEN3.5-44
    4.0 Ti-TEN4-40 Ti-TEN4-44
    4.5 Ti-TEN4.5-40 Ti-TEN4.5-44
View Complete Details

Small Fragment - Proximal Humerus Safety Lock Plate 3.5

Small Fragment Locking Implants are used in treatment of Osteomies, Nonunions and small fracture fixation such as fracture of Clavicle, Scapula, Olecranon, Humerus, Ulna, Radius, Pelvis, Distal Tibia and Fibula. These are also used in fractures fixation of long bones in Pediatric patients. Small Fragment System comprises Safety Locking and Standard Plates and Screws. The plates are classified according to their functions.

Locking Proximal Humerus Plate is used for complex and unstable fractures.

Indications Proximal Humerus

  • Multifragmentary (dislocated) fractures requiring open reduction
  • Unstable subcapital fractures
  • Subcapital pseudarthrosis
  • Osteotomies

Suture holes The fixation of additional wireloops or sutures attached to the tubercles (in 3- or 4-fragment fractures) neutralises the muscle tension and helps to maintain reduction.

The head of plate allows only 3.5 mm Safety Lock Screws and shaft of the plate allows both 3.5 mm Safety Lock and Cortical screws.

No. of Holes STAINLESS STEEL
5 SF-640.005
6 SF-640.006
7 SF-640.007
8 SF-640.008

No. of Holes TITANIUM
5 Ti-SF-640.005
6 Ti-SF-640.006
7 Ti-SF-640.007
8 Ti-SF-640.008
View Complete Details

Small Fragment - Distal Humerus Safety Lock Plate 2.7/3.5, Dorsolateral

  • The Distal Humerus Safety Lock Plate 2.7/3.5, Dorsolateral is available in various lengths. There are two version of the plate left and right separately designed for right and left humerus. The plates are pre-shaped to match the anatomy of the distal humerus with a limited contact low profile design.
  • The Head Region of the plate accommodates safety Lock Screw 2.7 mm-Self Tapping and shaft region accommodates both cortex screw 3.5 mm-self tapping and Saftey Lock screw 3.5 mm-self tapping
  • The Distal Humerus safety Lock Plate 2.7/3.5, Dorsolateral is indicated for intraarticular fractures of the distalo humerus, comminuted supracondylar fractures, osteotormies, and non-unions of the distal humerus.
No. ofHoles STAINLESS STEEL
Left Right
3 SF-601.03L SF-601.03R
5 SF-601.05L SF-601.05R
7 SF-601.07L SF-601.07R
9 SF-601.09L SF-601.09R
14 SF-601.14L SF-601.14R

No. ofHoles TITANIUM
Left Right
3 Ti-SF-601.03L Ti-SF-601.03R
5 Ti-SF-601.05L Ti-SF-601.05R
7 Ti-SF-601.07L Ti-SF-601.07R
9 Ti-SF-601.09L Ti-SF-601.09R
14 Ti-SF-601.14L Ti-SF-601.14R
View Complete Details

Small Fragment - Distal Humerus Safety Lock Plate 3.5, Extra-Articular

Indications:The 3.5 mm LCP Extra-articular Distal Humerus Plates are indicated for fractures of the distal humerus.

Plate features

    • Left and right plates are anatomically contoured to match the posterolateral distal humerus.
    • Two most distal holes are angled toward the capitulum and trochlea.
    • Plate head tapered to minimize soft tissue irritation.
    • A limited-contact plate design reduces plate-to-bone contact and helps to preserve the periosteal blood supply.

Anatomic reduction:Fracture reduction and fixation to restore anatomical relationships.

Stable fixation:Fracture fixation providing absolute or relative stability, as required by the patient, the injury, and the personality of the fracture.

Early, active mobilization:Early and safe mobilization and rehabilitation of the injured part and the patient as a whole.

Preservation of blood supply:Preservation of the blood supply to soft tissues and bone by gentle reduction techniques and careful handling.

No. ofHoles STAINLESS STEEL
Left Right
4 SF-612.04L SF-612.04R
6 SF-612.06L SF-612.06R
8 SF-612.08L SF-612.08R
10 SF-612.10L SF-612.10R
12 SF-612.12L SF-612.12R
14 SF-612.14L SF-612.14R

No. ofHoles TITANIUM
Left Right
4 Ti-SF-612.04L Ti-SF-612.04R
6 Ti-SF-612.06L Ti-SF-612.06R
8 Ti-SF-612.08L Ti-SF-612.08R
10 Ti-SF-612.10L Ti-SF-612.10R
12 Ti-SF-612.12L Ti-SF-612.12R
14 Ti-SF-612.14L Ti-SF-612.14R
View Complete Details

Small Fragment - Medial Distal Humerus Safety Lock Plate 2.7/3.5

  • The Medial Distal Humerus Safety Lock Plate 2.7/3.5, is available in various lengths. There are two version of the plate left and right separately designed for right and left humerus. The plates are pre-shaped to match the anatomy of the distal humerus with a limited contact low profile design.
  • The Head Region of the plate accommodates safety Lock Screw 2.7 mm-Self Tapping and shaft region accommodates both cortex screw 3.5 mm - Self Tapping and Saftey Lock Screw 3.5 mm - Self Tapping
  • The Medial Distal Humerus safety Lock Plate 2.7/3.5, Left Direction is indicated for intraarticular fractures of the Distal Humerus, comminuted supracondylar fractures, osteotormies, and non-unions of the Distal Humerus.
  • No. ofHoles STAINLESS STEEL
    Left Right
    3 SF-604.03L SF-604.03R
    5 SF-604.05L SF-604.05R
    7 SF-604.07L SF-604.07R
    9 SF-604.09L SF-604.09R
    14 SF-604.14L SF-604.14R
  • No. ofHoles TITANIUM
    Left Right
    3 Ti-SF-604.03L Ti-SF-604.03R
    5 Ti-SF-604.05L Ti-SF-604.05R
    7 Ti-SF-604.07L Ti-SF-604.07R
    9 Ti-SF-604.09L Ti-SF-604.09R
    14 Ti-SF-604.14L Ti-SF-604.14R
View Complete Details

Small Fragment - Metaphyseal Safety Lock Plate 3.5 For Distal, Medial Humerus

Plate Features:

Anatomically precontoured plate:plateThe anatomical shape of the plate has been especially designed to fit the complex shape of the medial part of the distal humerus.

Thinned plate profile:The distal part of the plate is tapered to preserve the thin soft tissue envelope of the distal humerus.

Notches on the plate shaft:The notches allow for additional lateral bending of the plate to deal with the wide anatomical variance of the humeri. The plate can be bent at max. 4 at each notch.

Optimal distal application of the locking screws:The distal end of the plate has been equipped with three threaded round holes intended for angular stable locking screws. Their specific orientation in combination with the thin plate profile allows stable fixation of the condylar zone and the articular surface while fully pre-serving the soft tissue, without any risk of screws penetrating the articulation.

Increased hole density for improved anchorage:The three distal LCP round holes allow inserting the screws closer to one another and hence an optimal fixation of the bone fragments.The elongated hole in the shaft facilitates fine tuning of the reduction and plate positioning in the longitudinal axis.Improved vascularization of the bone due to plate undercuts that reduce the plate-to-bone contact.

Indications:

Metaphyseal Safety Lock Plate 3.5 for Distal, Medial Humerus is an anatomically precontoured plate that permits an optimal treatment of juxta-articular distal humerus fractures. It takes into account the following peculiarities of the distal humerus: Thin soft-tissue envelope & complex shape of the bone.

No. of Holes STAINLESS STEEL
7 SF-611.07
9 SF-611.09
11 SF-611.11
13 SF-611.13
15 SF-611.15

No. of Holes TITANIUM
7 Ti-SF-611.07
9 Ti-SF-611.09
11 Ti-SF-611.11
13 Ti-SF-611.13
15 Ti-SF-611.15
View Complete Details

Small Fragment Anterolateral Distal Tibia Safety Lock Plate

Plate Features:

  • Proximal Tibia Safety Lock Plate 3.5mm is used for Non-unions, Malunions, and fractures of Proximal Tibia, including Simple, Comminuted, Lateral wedge, Depression, Medial wedge, Bicondylar, Combination of Lateral wedge and depression and fractures associated with shaft.
  • These plates can be anatomically contoured to match Proximal Lateral Tibia.
  • These plates are designed for both right or left Tibia and are available in a variety of lengths.
  • The head and three Proximal holes allow only 3.5 mm Safety Lock screws, rest holes allow both 3.5 mm Safety Lock and Cortical screws.
No. ofHoles STAINLESS STEEL
Left Right
4 SF-607.04L SF-607.04R
6 SF-607.06L SF-607.06R
8 SF-607.08L SF-607.08R
10 SF-607.10L SF-607.10R
12 SF-607.12L SF-607.12R
14 SF-607.14L SF-607.14R
16 SF-607.16L SF-607.16R

No. ofHoles TITANIUM
Left Right
4 Ti-SF-607.04L Ti-SF-607.04R
6 Ti-SF-607.06L Ti-SF-607.06R
8 Ti-SF-607.08L Ti-SF-607.08R
10 Ti-SF-607.10L Ti-SF-607.10R
12 Ti-SF-607.12L Ti-SF-607.12R
14 Ti-SF-607.14L Ti-SF-607.14R
16 Ti-SF-607.16L Ti-SF-607.16R

Safety Locking Implants: Safety Locking Implants comprise Safety Locking Plates and Screws. Safety Locking Plates are similar to Standard Plates that have numeral-8 shaped holes, on one side the hole is threaded, so that it can accommodate locking screws. Use of these plates depend upon the fracture situation. These plates can be used as Compression plates, Locked fixations or as Standard implants as the need may be. Safety locking feature provides angular stability.
View Complete Details

Small Fragment - Medial Distal Tibia Safety Lock Plate

Indications:

    • Extra-articular and simple intra-articular distal tibial fractures.
    • Distal tibial fractures, percutaneous or reducible by limited arthrotomy.
    • Distal tibial fracture extending into the diaphyseal area.

Plate Features:

  • These Plates can be anatomically contoured to match with the Distal Medial Tibia.
  • These plates are designed for both right and left tibia and are available in a variety of lengths.
  • The head hole allows only 3.5 mm Safty Lock screws, rest holes allow both 3.5 mm Safety Lock and Cortical screws.
  • Screws : For Combi holes - 3.5 Locking, 3.5 Cortical, 4.0 Cancellous.For Round Locking Holes - 3.5 Locking, 2.7 or 3.5 Cortical, 4.0 Cancellous.
No. ofHoles STAINLESS STEEL
Left Right
4 SF-645.04L SF-645.04R
6 SF-645.06L SF-645.06R
8 SF-645.08L SF-645.08R
10 SF-645.10L SF-645.10R
12 SF-645.12L SF-645.12R
14 SF-645.14L SF-645.14R

No. ofHoles TITANIUM
Left Right
4 Ti-SF-645.04L Ti-SF-645.04R
6 Ti-SF-645.06L Ti-SF-645.06R
8 Ti-SF-645.08L Ti-SF-645.08R
10 Ti-SF-645.10L Ti-SF-645.10R
12 Ti-SF-645.12L Ti-SF-645.12R
14 Ti-SF-645.14L Ti-SF-645.14R
View Complete Details

Small Fragment - Pilon Safety Lock Plate 2.7/3.5 - Cruciform

Indication:

  • Distal articular fractures of the tibia (pilon fractures) with emphasis on complex articular reconstruction

Small Fragment Locking Implants are used in treatment of Osteomies, Nonunions and small fracture fixation such as fracture of Clavicle, Scapula, Olecranon, Humerus, Ulna, Radius, Pelvis, Distal Tibia and Fibula. These are also used in fractures fixation of long bones in Pediatric patients. Small Fragment System comprises Safety Locking and Standard Plates and Screws. The plates are classified according to their functions.

Safety Locking Implants: Safety Locking Implants comprise Safety Locking Plates and Screws. Safety Locking Plates are similar to Standard Plates that have numeral-8 shaped holes, on one side the hole is threaded, so that it can accommodate locking screws. Use of these plates depend upon the fracture situation. These plates can be used as Compression plates, Locked fixations or as Standard implants as the need may be. Safety locking feature provides angular stability.
No. of Holes STAINLESS STEEL
7 SF-649.07
9 SF-649.09

No. of Holes TITANIUM
7 Ti-SF-649.07
9 Ti-SF-649.09
View Complete Details

Small Fragment - Metaphyseal Safety Lock Plate 3.5

Indications:

The Metaphyseal plates are indicated for extra-articular fractures of the metaphyseal area that extend into the shaft. The 3.5 plate is indicated for distal tibial and distal humeral fractures.

Plate Features:

  • Safety Locking combi-holes allow uncompromising combinations:The combi-hole allows an internal plate fixation using standard screws, angular stable locking screws, or a combination of both. This takes into account the most diverse intraoperative requirements.
  • Angular stability allows for better fixation:The angle- and axis-stable locking screws prevent loss of reduction under load. A precise anatomical contouring of the plate is unnecessary when using this system as a locking internal fixator.
  • Easier plate contouring due to thinned plate profile:The plate design facilitates anatomical contouring considerably, whilst taking into account the distinctive features of the metaphyseal bone area (e.g. complex bone shapes, thin soft tissue envelope).
  • The Metaphyseal Safety Lock Plates have both compression and locking holes. All holes of plate accept 3.5 mm cortex, 3.5mm safety lock and 4.0 mm cancellous screws.
No. of Holes TITANIUM
6 Ti-SF-613.06
7 Ti-SF-613.07
8 Ti-SF-613.08
9 Ti-SF-613.09
10 Ti-SF-613.10
11 Ti-SF-613.11
12 Ti-SF-613.12
14 Ti-SF-613.13
16 Ti-SF-613.14
18 Ti-SF-613.15
No. of Holes STAINLESS STEEL
6 SF-613.06
7 SF-613.07
8 SF-613.08
9 SF-613.09
10 SF-613.10
11 SF-613.11
12 SF-613.12
14 SF-613.13
16 SF-613.14
18 SF-613.15
View Complete Details

Small Fragment - Clavicle Safety Lock Plate 3.5 - Anterior

Indications:

    • Fractures of the clavicle shaft
    • Malunions of the clavicle shaft
    • Non-unions of the clavicle shaft

Plate Features:

  • Anatomically pre-shaped, twisted design.
  • Due to Lateral superior placement, there is less need to detach muscles than with anterior placement.
  • Undercuts reduce impairment of blood supply.
  • Good purchase also in osteoporotic bone and in multifragment fractures.
  • Tapered plate tip facilitates percutaneous insertion and prevents soft tissue irritation.
No. ofHoles TITANIUM
Left Right
6 Ti-SF-620.06L Ti-SF-620.06R
7 Ti-SF-620.07L Ti-SF-620.07R
8 Ti-SF-620.08L Ti-SF-620.08R

No. ofHoles STAINLESS STEEL
Left Right
6 SF-620.06L SF-620.06R
7 SF-620.07L SF-620.07R
8 SF-620.08L SF-620.08R
View Complete Details

Small Fragment - Clavicle Safety Lock Plate 3.5 - Anterior With Lateral Extension

Indications:

  • Fractures of the lateral clavicle
  • Malunions of the lateral clavicle
  • Non-unions of the lateral clavicle
  • Available in longer versions for lateral fractures with associated shaft fractures

Plate Features:

  • Anatomically pre-shaped, twisted design.
  • Due to Lateral superior placement, there is less need to detach muscles than with anterior placement.
  • Undercuts reduce impairment of blood supply.
  • Good purchase also in osteoporotic bone and in multifragment fractures.
  • Tapered plate tip facilitates percutaneous insertion and prevents soft tissue irritation.
  • No. ofHoles STAINLESS STEEL
    Left Right
    3 SF-622.03L SF-622.03R
    4 SF-622.04L SF-622.04R
    5 SF-622.05L SF-622.05R
    6 SF-622.06L SF-622.06R
    7 SF-622.07L SF-622.07R
    8 SF-622.08L SF-622.08R
  • No. ofHoles TITANIUM
    Left Right
    3 Ti-SF-622.03L Ti-SF-622.03R
    4 Ti-SF-622.04L Ti-SF-622.04R
    5 Ti-SF-622.05L Ti-SF-622.05R
    6 Ti-SF-622.06L Ti-SF-622.06R
    7 Ti-SF-622.07L Ti-SF-622.07R
    8 Ti-SF-622.08L Ti-SF-622.08R
View Complete Details

Small Fragment - Calcaneal Safety Lock Plate 3.5

Indications:

  • Calcaneus fracture: Intra-articular & Extra-articular
  • Multiple Fragment Fractures of Calcaneus
  • Tongue-type Calcaneus Fractures
  • Calcaneus fracture: Joint depression
  • Poor heel position and shape
  • Displaced articular involvement

Available in 60 and 70 mm lengths. These plates are designed for both Right and Left sides.All holes of the plate allow 3.5 mm safety lock screws.

Lengthin mm STAINLESS STEEL
Left Right
60 SF-137.160L SF-137.160R
70 SF-137.170L SF-137.170R

Lengthin mm TITANIUM
Left Right
60 Ti-SF-137.160L Ti-SF-137.160R
70 Ti-SF-137.170L Ti-SF-137.170R
View Complete Details

Small Fragment - Calcaneus Safety Lock Plate 3.5

Indications:

    • Calcaneus fracture: Intra-articular & Extra-articular
    • Multiple Fragment Fractures of Calcaneus
    • Tongue-type Calcaneus Fractures
    • Calcaneus fracture: Joint depression
    • Poor heel position and shape
    • Displaced articular involvement

Plate features:

  • Bending tabs give support to plantar fragments and anterior process.
  • Lateral application.
  • Holes with threaded offer a fixed-angle construct to buttress the articular surfaces of the calcaneus.
  • Permit multiple points of fixation to buttress small fragments.
  • All holes of the plate allow 3.5 mm safety lock screws.
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.

Available in 60 and 70 mm lengths. These plates are designed for both Right and Left sides.All holes of the plate allow 3.5 mm safety lock screws.

Size Lengthmm STAINLESS STEEL
Left Right
Extra Small 64 SF-138.64L SF-138.64R
Small 69 SF-138.69L SF-138.69R
Large 76 SF-138.76L SF-138.76R
Extra Large 81 SF-138.81L SF-138.81R

Size Lengthmm TITANIUM
Left Right
Extra Small 64 Ti-SF-138.64L Ti-SF-138.64R
Small 69 Ti-SF-138.69L Ti-SF-138.69R
Large 76 Ti-SF-138.76L Ti-SF-138.76R
Extra Large 81 Ti-SF-138.81L Ti-SF-138.81R
View Complete Details

Small Fragment - Lateral Distal Fibula Safety Lock Plate 2.7/3.5

Indications:

Lateral Distal Fibula Safety Lock Plate 2.7/3.5 is indicated for fractures, osteotomies and nonunions of the metaphyseal and diaphyseal region of the distal fibula, especially in osteopenic bone.

Plate Features:

  • Anatomically contoured Lateral Distal Fibula Safety Lock Plate 2.7/3.5.
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
No. ofHoles STAINLESS STEEL
Left Right
3 SF-652.03L SF-652.03R
4 SF-652.04L SF-652.04R
5 SF-652.05L SF-652.05R
6 SF-652.06L SF-652.06R
7 SF-652.07L SF-652.07R

No. ofHoles STAINLESS STEEL
Left Right
3 Ti-SF-652.03L Ti-SF-652.03R
4 Ti-SF-652.04L Ti-SF-652.04R
5 Ti-SF-652.05L Ti-SF-652.05R
6 Ti-SF-652.06L Ti-SF-652.06R
7 Ti-SF-652.07L Ti-SF-652.07R
View Complete Details

Small Fragment - Volar Column Distal Radius Safety Lock Plate 2.4 (8 Head Holes)

Indications:

Volar Column Distal Radius Safety Lock Plate 2.4 (8 Head Holes) is indicated for the fixation of intra- and extra-articular fractures and osteotomies of the distal radius. Multiple distal locking screw options offer a fixed-angle construct to support the articular surface, reduce the need for bone graft and obtain fixation in osteoporotic bone.

Plate Features:

  • Anatomically contoured Volar Column Distal Radius Safety Lock Plate 2.4.
  • Multiple locking screw option in plate head assist in fixation of the radial and intermediate column.
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-120.803L
Right 3 SF-120.803R
Left 4 SF-120.804L
Right 4 SF-120.804R
Left 5 SF-120.805L
Right 5 SF-120.805R

L/R No. of Holes TITANIUM
Left 3 Ti-SF-120.803L
Right 3 Ti-SF-120.803R
Left 4 Ti-SF-120.804L
Right 4 Ti-SF-120.804R
Left 5 Ti-SF-120.805L
Right 5 Ti-SF-120.805R
View Complete Details

Small Fragment - Volar Column Distal Radius Safety Lock Plate 2.4 (9 Head Holes)

Indications:

Volar Column Distal Radius Safety Lock Plate 2.4 (9 Head Holes) is indicated for the fixation of intra- and extra-articular fractures and osteotomies of the distal radius. Multiple distal locking screw options offer a fixed-angle construct to support the articular surface, reduce the need for bone graft and obtain fixation in osteoporotic bone.

Plate Features:

  • Anatomically contoured Volar Column Distal Radius Safety Lock Plate 2.4.
  • Multiple locking screw option in plate head assist in fixation of the radial and intermediate column.
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-120.903L
Right 3 SF-120.903R
Left 4 SF-120.904L
Right 4 SF-120.904R
Left 5 SF-120.905L
Right 5 SF-120.905R
L/R No. of Holes TITANIUM
Left 3 Ti-SF-120.903L
Right 3 Ti-SF-120.903R
Left 4 Ti-SF-120.904L
Right 4 Ti-SF-120.904R
Left 5 Ti-SF-120.905L
Right 5 Ti-SF-120.905R
View Complete Details

Small Fragment - Volar Distal Radius Safety Lock Plate 2.4, Extra-Articular, Extra-long

Indications:

Volar Distal Radius Safety Lock Plate 2.4, Extra-Articular, Extra-long is indicated for treating distal radius fractures with extension into the shaft.

Plate Features:

  • Anatomically contoured Volar Distal Radius Safety Lock Plate 2.4, Extra-Articular, Extra-long.
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
HeadHoles ShaftHoles Stainless Steel
4 8 SF-122.108
4 10 SF-122.110
4 12 SF-122.112

HeadHoles ShaftHoles TITANIUM
4 8 Ti-SF-122.108
4 10 Ti-SF-122.110
4 12 Ti-SF-122.112
View Complete Details

Small Fragment - Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (5 Head Holes)

Indications:

Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (5 Head Holes) is indicated for displaced extra-articular and intra-articular distal radius fractures and corrective osteotomies of the distal radius.

Plate Features:

  • Anatomically contoured Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (5 Head Holes)
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-121.504L
Right 3 SF-121.504R
Left 5 SF-121.505L
Right 5 SF-121.505R

L/R No. of Holes TITANIUM
Left 3 Ti-SF-121.504L
Right 3 Ti-SF-121.504R
Left 5 Ti-SF-121.505L
Right 5 Ti-SF-121.505R
View Complete Details

Volar Distal Radius Safety Lock Plate

Indications:

Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (4 Head Holes) is indicated for displaced extra-articular and intra-articular distal radius fractures and corrective osteotomies of the distal radius.

Plate Features:

  • Anatomically contoured Volar Distal Radius Safety Lock Plate 2.4, Extra Articular (4 Head Holes)
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.

L/R No. of Holes Stainless Steel
Left 3 SF-121.304L
Right 3 SF-121.304R
Left 5 SF-121.305L
Right 5 SF-121.305R

L/R No. of Holes TITANIUM
Left 3 Ti-SF-121.304L
Right 3 Ti-SF-121.304R
Left 5 Ti-SF-121.305L
Right 5 Ti-SF-121.305R
View Complete Details

Small Fragment - Volar Distal Radius Safety Lock Plate 2.4, Juxta-Articular (5 Head Holes)

Indications:

Volar Distal Radius Safety Lock Plate 2.4, juxta-articular (5 Head Holes) is indicated for displaced extra-articular and intra-articular distal radius fractures and corrective osteotomies of the distal radius.

Plate Features:

  • Anatomically contoured Volar Distal Radius Safety Lock Plate 2.4, juxta-articular (5 Head Holes)
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-123.503L
Right 3 SF-123.503R
Left 5 SF-123.505L
Right 5 SF-123.505R

L/R No. of Holes TITANIUM
Left 3 Ti-SF-123.503L
Right 3 Ti-SF-123.503R
Left 5 Ti-SF-123.505L
Right 5 Ti-SF-123.505R
View Complete Details

Small Fragment - Volar Distal Radius Buttress Safety Lock Plate 2.4, Juxta-Articular (5 Head Holes)

Indications:

Volar Distal Radius Buttress Safety Lock Plate 2.4, juxta-articular (5 Head Holes) is indicated for displaced extra-articular and intra-articular distal radius fractures and corrective osteotomies of the distal radius.

Plate Features:

  • Anatomically contoured Volar Distal Radius Buttress Safety Lock Plate 2.4, juxta-articular (5 Head Holes).
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone.
L/R No. of Holes Stainless Steel
Left 3 SF-124.503L
Right 3 SF-124.503R

L/R No. of Holes TITANIUM
Left 3 Ti-SF-124.503L
Right 3 Ti-SF-124.503R
View Complete Details

Small Fragment - Dorsal Distal Radius Safety Lock Plate 2.4 - Straight

Indications:

    • Dorsally displaced distal radius fractures.
    • Combination of distal radius with carpal and metacarpal fractures.
    • Corrective osteotomies.

Plate Features:

  • Anatomically contoured Dorsal Distal Radius Safety Lock Plate 2.4 - Straight.
  • Locking plates provides anatomical reduction. It means adaptation of fracture fragments to restore normal anatomy.
  • stability in fixation: It gives stability in fixation as required by the nature of fracture. Plate provides optimal compression and stability.
  • Plate preserves blood supply to soft tissues and bone
No. of Holes Stainless Steel
5 SF-125.105
6 SF-125.106

No. of Holes TITANIUM
5 Ti-SF-125.105
6 Ti-SF-125.106
View Complete Details

Small Fragment - Olecranon Safety Lock Plate 3.5

Indications:

    • Complex intra-articular and extra-articular olecranon fractures.
    • Pseudoarthrosis of the proximal ulna.
    • Simple olecranon fractures.
    • Repair of the olecranon after osteotomies in distal humerus surgery.

Plate Features:

  • Angular stable fixation of fragments regardless of bone quality.
  • Minimised risk of primary and secondary loss of reduction, even under high dynamic loading.
  • Reduced impairment of periosteal blood supply due to the limited plate contact.
No. ofHoles STAINLESS STEEL
Left Right
2 SF-647.02L SF-647.02R
4 SF-647.04L SF-647.04R
6 SF-647.06L SF-647.06R
8 SF-647.08L SF-647.08R
10 SF-647.10L SF-647.10R
12 SF-647.12L SF-647.12R

No. ofHoles TITANIUM
Left Right
2 Ti-SF-647.02L Ti-SF-647.02R
4 Ti-SF-647.04L Ti-SF-647.04R
6 Ti-SF-647.06L Ti-SF-647.06R
8 Ti-SF-647.08L Ti-SF-647.08R
10 Ti-SF-647.10L Ti-SF-647.10R
12 Ti-SF-647.12L Ti-SF-647.12R
View Complete Details

Large Fragment - Locking- Broad Curved Safety Lock Plate 4.5/5.0

  • Broad Curved Safety Lock Plate 4.5/5.0 is used to fix the Femoral shaft fracture.
  • The curve in the plate easily fit over the Femur.
  • Used with 4.5mm cortical and 5.0mm locking head screw.
  • No. of Holes Length mm STAINLESS STEEL
    12 229 SF-619.12
    13 247 SF-619.13
    14 265 SF-619.14
    15 282 SF-619.15
    16 300 SF-619.16
    17 318 SF-619.17
    18 336 SF-619.18
  • No. of Holes Length mm TITANIUM
    12 229 Ti-SF-619.12
    13 247 Ti-SF-619.13
    14 265 Ti-SF-619.14
    15 282 Ti-SF-619.15
    16 300 Ti-SF-619.16
    17 318 Ti-SF-619.17
    18 336 Ti-SF-619.18
View Complete Details

Large Fragment - Locking- Pelvis Safety Lock Plate

  • Pelvis Safety Lock Plate. These plates are indicated for the fractures of Pubic bone with or without disruption of Pubic symphysis.
  • It is not recommended during pregnancy.
  • Anatomically designed plate fits over Pubic arch.
No. of Holes STAINLESS STEEL
4 SF-648.004
6 SF-648.006

No. of Holes TITANIUM
4 Ti-SF-648.004
6 Ti-SF-648.006
View Complete Details

Proximal Femoral Safety Lock Plate

  • The Proximal Femoral Safety Lock Plate 4.5/5.0/7.3 is intended for fractures of the femur including: fractures of the trochanteric region , trochanteric simple, cervicotrochanteric region, trochanterodiaphyseal, multifragmentary pertrochanteric, intertrochanteric, intertrochanteric reversed, or transverse or with additional fracture of medial cortex.
  • Fractures of the proximal end of the femur combined with ispsilateral shaft fractures, metastatic fracture of the proximal femur and osteotomies of the proximal femur.
  • All holes of the shaft accommodate cortex screw 4.5mm, self Tapping and safety Lock Screw 5.0mm.
No. ofHoles Lengthin mm STAINLESS STEEL
Left Right
2 139 SF-656.002L SF-656.002R
4 175 SF-656.004L SF-656.004R
6 211 SF-656.006L SF-656.006R
8 247 SF-656.008L SF-656.008R
10 283 SF-656.010L SF-656.010R
12 319 SF-656.012L SF-656.012R
14 355 SF-656.014L SF-656.014R
16 391 SF-656.016L SF-656.016R

No. ofHoles Lengthin mm TITANIUM
Left Right
2 139 Ti-SF-656.002L Ti-SF-656.002R
4 175 Ti-SF-656.004L Ti-SF-656.004R
6 211 Ti-SF-656.006L Ti-SF-656.006R
8 247 Ti-SF-656.008L Ti-SF-656.008R
10 283 Ti-SF-656.010L Ti-SF-656.010R
12 319 Ti-SF-656.012L Ti-SF-656.012R
14 355 Ti-SF-656.014L Ti-SF-656.014R
16 391 Ti-SF-656.016L Ti-SF-656.016R
View Complete Details

Distal Femoral Safety Lock Plate

  • Distal Femoral Safety Lock Plate 4.5/5.0 are intended for buttressing multifragmentary distal femur fractures including: supracondylar, intra-articular condylar, periprosthetic fractures and fractures in normal or osteopenic bone, nonunions and malunions, and osteotomies of the femur.
  • All holes accommodate Cortex screw 4.5mm, Self Tapping and Safety Lock Screw 5.0mm.
No. ofHoles Lengthin mm STAINLESS STEEL
Left Right
5 156 SF-635.005L SF-635.005R
6 176 SF-635.006L SF-635.006R
7 196 SF-635.007L SF-635.007R
8 216 SF-635.008L SF-635.008R
9 236 SF-635.009L SF-635.009R
10 256 SF-635.010L SF-635.010R
11 276 SF-635.011L SF-635.011R
12 296 SF-635.012L SF-635.012R
13 316 SF-635.013L SF-635.013R

No. ofHoles Lengthin mm TITANIUM
Left Right
5 156 Ti-SF-635.005L Ti-SF-635.005R
6 176 Ti-SF-635.006L Ti-SF-635.006R
7 196 Ti-SF-635.007L Ti-SF-635.007R
8 216 Ti-SF-635.008L Ti-SF-635.008R
9 236 Ti-SF-635.009L Ti-SF-635.009R
10 256 Ti-SF-635.010L Ti-SF-635.010R
11 276 Ti-SF-635.011L Ti-SF-635.011R
12 296 Ti-SF-635.012L Ti-SF-635.012R
13 316 Ti-SF-635.013L Ti-SF-635.013R
View Complete Details

Metaphyseal Safety Lock Plate

Indication:

The Metaphyseal plates are indicated for extra-articular fractures of the metaphyseal area that extend into the shaft. The Metaphyseal plate 3.5/4.5/5.0 is indicated for distal tibial and proximal humeral fractures.

Plate Features:

  • Safety Locking combi-holes allow uncompromising combinations:The combi-hole allows an internal plate fixation using standard screws, angular stable locking screws, or a combination of both. This takes into account the most diverse intraoperative requirements.
  • Angular stability allows for better fixation:The angle- and axis-stable locking screws prevent loss of reduction underload. A precise anatomical contouring of the plate is unnecessary when using this system as a locking internal fixator.
  • Easier plate contouring due to thinned plate profile:The plate design facilitates anatomical contouring considerably, whilst taking into account the distinctive features of the metaphyseal bone area (e.g. complex bone shapes, thin soft tissue envelope).
  • Extra-articular fixation with the advantage of angled locking screws:The two distal holes in the thinned area of the plate, which are angled at 11 towards the centre of the plate, allow an optimal application of the locking screws in the epiphyseal area.
  • Improved vascularization of the periost due to plate under cuts that reduce the plate-to-bone contact.
  • The elongated hole in the shaft optimizes fine tuning of the reduction in the longitudinal axis.
  • The Metaphyseal Safety Lock Plates have both compression and locking holes. The plates accept 3.5 / 4.5 mm cortex, 3.5, 4.0, & 5.0 mm safety lock and 4.0mm / 6.5 mm cancellous screws.
No. of Holes Length mm STAINLESS STEEL
5+3 118 SF-615.03
5+4 136 SF-615.04
5+5 154 SF-615.05
5+6 172 SF-615.06
5+7 190 SF-615.07
5+8 208 SF-615.08
5+9 226 SF-615.09
5+11 262 SF-615.11
5+13 298 SF-615.13
5+15 334 SF-615.15

No. of Holes Length mm TITANIUM
5+3 118 Ti-SF-615.03
5+4 136 Ti-SF-615.04
5+5 154 Ti-SF-615.05
5+6 172 Ti-SF-615.06
5+7 190 Ti-SF-615.07
5+8 208 Ti-SF-615.08
5+9 226 Ti-SF-615.09
5+11 262 Ti-SF-615.11
5+13 298 Ti-SF-615.13
5+15 334 Ti-SF-615.15

View Complete Details

Metaphyseal Safety Lock Plate For Distal Tibia

Indications:

The LCP Metaphyseal Plate for distal medial tibia is a preshaped plate that allows optimal treatment of juxta-articular fractures of the distal tibia extending into the shaft area. This plate takes the following characteristics of the distal tibia into account:

    • Thin, soft tissue coverage.
    • Complex anatomic shape of the bone.

Plate Features:

  • Anatomically precontoured plate: The anatomical shape of the plate is especially designed to fit the complex shape of the distal part of the bone. A twist of the plate optimizes the fit on the tibia.
  • Thinned plate profile: The distal part of the plate is tapered to preserve the thin soft tissue envelope of the distal tibia.
  • Optimal distal application of the locking head screws: The specific orientation of the four distal screws allows optimal fixation in the epiphyseal area without penetrating the articulation.
  • Improved vascularisation of the bone due to plate undercuts that reduce the plate-to-bone contact.
No. ofHoles Lengthin mm STAINLESS STEEL
Left Right
4+4 123 SF-617.04L SF-617.04R
4+5 141 SF-617.05L SF-617.05R
4+6 159 SF-617.06L SF-617.06R
4+7 177 SF-617.07L SF-617.07R
4+8 195 SF-617.08L SF-617.08R
4+9 213 SF-617.09L SF-617.09R
4+10 231 SF-617.10L SF-617.10R
4+12 267 SF-617.11L SF-617.11R
4+14 303 SF-617.12L SF-617.12R
4+16 339 SF-617.13L SF-617.13R
4+18 375 SF-617.14L SF-617.14R
4+20 411 SF-617.15L SF-617.15R

No. ofHoles Lengthin mm TITANIUM
Left Right
4+4 123 Ti-SF-617.04L Ti-SF-617.04R
4+5 141 Ti-SF-617.05L Ti-SF-617.05R
4+6 159 Ti-SF-617.06L Ti-SF-617.06R
4+7 177 Ti-SF-617.07L Ti-SF-617.07R
4+8 195 Ti-SF-617.08L Ti-SF-617.08R
4+9 213 Ti-SF-617.09L Ti-SF-617.09R
4+10 231 Ti-SF-617.10L Ti-SF-617.10R
4+12 267 Ti-SF-617.11L Ti-SF-617.11R
4+14 303 Ti-SF-617.12L Ti-SF-617.12R
4+16 339 Ti-SF-617.13L Ti-SF-617.13R
4+18 375 Ti-SF-617.14L Ti-SF-617.14R
4+20 411 Ti-SF-617.15L Ti-SF-617.15R
View Complete Details

Craniomaxillofacial Orbital Safety Lock Plate

Indications

NET MIDFACE CMF Plating System is intended for use in selective trauma of the midface and craniofacial skeleton; craniofacial surgery; reconstructive procedures; and selective orthognathic surgery of the maxilla and chin.

Contraindications

The use in areas with active or latent infection or insufficient quantity or quality of bone.

Screw  in mm No. of Holes Titanium
2.0 04 Ti-SF-24.13
2.0 06 Ti-SF-24.14
2.0 08 Ti-SF-24.15
2.0 10 Ti-SF-24.18
2.5 04 Ti-SF-24.22
2.5 06 Ti-SF-24.23
2.5 08 Ti-SF-24.24
2.5 10 Ti-SF-24.25
View Complete Details

RH403 - Frog Splint

    • Size:S, M, L

Feature:

    • Foam padded aluminium splint in unique shape to cover the dorsal surface of finger to remain open
    • Four extended arms to ensure good fitting.

Application:

  • Hyper flexion injuries
  • Swan neck deformity
  • To hold distal inter phalangeal joints in correct alignment
  • Collateral ligament injuries of distal inter phalangeal joint
View Complete Details

RH409 - Thumb Spica Splint

  • Size:Universal

Feature:

  • High quality fabric with suede lining for comfort and durability
  • Allows performance of routine tasks in comfort as it limits extreme motion of the joint of the thumb.

Application:

  • Designed for patients with painful wrists and thumb tendentious
  • Splint provides light compression to assist in decreasing pain and relieving inflammation
View Complete Details

RH418 - Wrist Forearm Splint

    • Size:S, M, L, XL (Left, Right)

Feature:

    • Pre shaped splint for immobilization in dorsiflexion.
    • High quality fabric and foam padding for comfort wear.
    • Thumb flap with velcro closure.

Application:

  • Strain and sprain in the wrist.
  • Early cast removal.
  • Minor fractures of the wrist and distal forearm.

Item Code Type
RH418 Wrist And Forearm Splint, Left.
RH419 Wrist And Forearm Splint, Right.
View Complete Details

RH524 - Knee Immobilizer

    • Size:S, M, L, XL, XXL

Feature:

    • High quality foam, fused fabric with metallic splinting for comfort and rigid support
    • Velcro closures for easy and quick application
    • Anatomically shaped splinting for proper fit.

Application:

  • An excellent product for support and stability to the injured knee
  • Emergency care in case of fracture, muscle / ligament /tendon injury or dislocation of the knee
  • Post operative rehabilitative care
View Complete Details

RH604 Sleeping Cervical Traction Kit

    • Size:Universal

Feature:

    • Padding on head halter to give comfortable wear
    • Spreader bar and pulley system provided
    • Heavy-duty weight bag with separate graduations for water and sand
    • Heavy-duty strings provided in the kit.

Application:

  • Traction upon medical practitioners recommendation.
View Complete Details

RH605 -Sitting Cervical Traction Kit

  • Size:Universal

Feature:

  • Padding on head halter to give comfortable wear
  • Spreader bar and pulley system provision
  • Heavy-duty weight bag with separate graduations for water and sand
  • Heavy-duty strings provided in the kit.

Application:

  • Cervical spine traction in sitting position
  • For short time cervical traction in muscle spasm
  • Cervical spine dislocation for continuous
View Complete Details

RH701 - Skin Traction Kit

    • Size:Child, Adult

Feature:

    • Foam padded heavy-duty fabric and crepe bandage provided to wrap around for below knee skin traction
    • Heavy-duty strings provided
    • Availability of Pulley system
    • Heavy-duty weight bag with separate graduations for water and sand.

Application:

  • Below knee traction to relieve pain in the back and knee region.
View Complete Details

RH819 - Fracture Bracing Joint

    • Size:Universal

Feature:

    • Flexible high-density unbreakable plastic. Suitable to be used on cast. Attaches directly to the above knee and below knee sections of cast.

Application:

  • Fracture bracing to provide functional mobility and early ambulation in post acute fracture. Post acute fracture application to provide mobility and increased muscle activity. Provides early ambulation with fractures of distal femur and proximal tibia.
View Complete Details

Foot Step Single SS

Specifications/Details :

  • Frame made up of SS tube fitted on PVC stumps.
  • Step made up of SS Shut
  • Size: L 450 x W 230 x H 230 mm
View Complete Details

Kick Basin

Specifications/Details:

  • Stainless steel pipe construction mounted on three 10 cms. dia. castors.
  • Supplied with one 35 cms. dia. S.S. Basin.
View Complete Details

Stretcher For Ambulance Car

  • The Bed Surface of the stretcher is made of foamed cushion with adjustable backrest which makes the patient feel more comfortable.
  • It has low frame structure, so that it can move on the ground and can also be lifted as a stretcher.
  • The both ends of the stretcher have opening circles which are used for transporting the patients. Salvage stretcher can be put inside the stretcher.
  • Unfolded Size (LxWxH): 190x55x42cm, Self-weight: 25 kg, Load Bearing: 159 kg.
  • Framework made of light weight aluminium. Maximum backrest adjustable: 65.
  • Suitable for the ambulances where the wheel height is less than 29cm.
View Complete Details

Wheelchair Economy Type

  • Chromed Steel Frame.
  • Fixed Armrest, Fixed Footrest.
  • Solid Castor, Solid Rear Wheel With Spokes.
  • Patient Controlled Brakes.
View Complete Details

Wheelchair Children

  • Chromed Steel Frame.
  • Fixed Armrest, Fixed Footrest.
  • Solid Castor, Solid Rear Wheel With Spokes.
  • Patient Controlled Brakes.
View Complete Details

Wheelchair Heavy Duty

  • Chromed Steel Frame, Double Cross bar.
  • Fixed Armrest, Fixed Footrest.
  • Solid Castor, Solid Real Wheel Plastic.
  • Patient Controlled Brakes.
View Complete Details

Wheelchair Detachable Foot Rest

  • Steel Powder Coating.
  • Flip Up Armrest, Detachable Footrest.
  • Solid Castor, Solid Rear Wheel Plastic.
  • Patient Controlled Brakes.
View Complete Details

Wheelchair Detachable Arm And Foot Rest

  • Steel Powder Coating.
  • Detachable Armrest, Detachable Footrest.
  • Solid Castor, Solid Rear Wheel With Spokes.
  • Patient Controlled Brakes.
View Complete Details

Wheelchair Detachable Arm Rest

  • Chromed Steel Frame.
  • Detachable Armrest, Elevating Footrest.
  • PU Castor, Pneumatic Rear Wheel With Spokes.
  • Patient Controlled Brakes.
View Complete Details

Walker Foldable With Two Wheels

  • Walker foldable with two wheels.
  • Aluminium Framework.
  • Height Adjustable 78-96 cm.
  • Seat Width 44 cm.
View Complete Details

Walker Rollator Foldable Aluminium

  • Walker Rollator foldable with two wheels.
  • Aluminium Framework.
  • Height Adjustable 81-91 cm.
  • Seat Width 47 cm.
View Complete Details

Blood Donation Chair Electric

  • Blood Donation Chair 3 Function - Remote controlled electrically operated backrest, leg section and height adjustment.
  • Linak motor controls
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us