Fluke 17B Plus Digital Multimeter, Operating Temperature : 0 °C to 40 °C

Listing ID #3766192

  • Brand NameFluke
  • Operating Temperature0 °C to 40 °C
  • Battery type2 AA, NEDA 15A, IEC LR6
  • Operating temperatures18 to 28 Deg. Cel.
  • Supply Type Supplier
Preferred Buyer From : Anywhere in India
View More Details
Send Enquiry

Company Information

  • Member Since 7 Years
  • Nature of Business Retailer
  • GST No. 27AAZPI9506L1ZU

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Brand Name Fluke
  • Operating Temperature 0 °C to 40 °C
  • Electromagnetic environment IEC 61326-1: Portable
  • Maximum voltage between any terminal and earth ground 1000 V
  • Fuse protection for current inputs 440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only
  • Storage Temperature -30 °C to 60 °C
  • Weight 455 g
  • Storage 12,000 m
  • Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
  • Benefit Frequency and temperature measurement
  • Display (LCD) 4000 counts, updates 3/sec
  • Operating 2000 m
  • Safety IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
  • Battery type 2 AA, NEDA 15A, IEC LR6
  • Electromagnetic compatibility Applies to use in Korea only
  • Operating temperatures 18 to 28 Deg. Cel.
  • Size (HxWxL) 183 x 91 x 49.5 mm
  • Operation Easy to use with one hand
  • IP rating IP 40

The Fluke 17B+ digital multimeter does all that and more.  Common basic electrical measurements plus temperature, frequency and duty cycle.  Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need.
Features :

  • 600 V Cat III safety rating
  • 50% bigger display with bright white backlight
  • Over-voltage indicator
  • Frequency and temperature measurement
  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A current
  • Diode test, data hold


Accuracy Specifications : Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of : ± (% of Reading + Number of Least Significant Digits).
Battery life : 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Operating humidity

  • Non-condensing (<10°C)
    • ≤90% RH at 10 °C to 30 °C;
    • ≤75% RH at 30 °C to 40 °C
  • 40 MΩ range
    • ≤80% RH at 10 °C to 30 °C;
    • ≤70% RH at 30 °C to 40 °C


Fluke TPAK ToolPak™ Magnetic Meter Hanger Kit includes:

  • 9 inch hook and loop strap
  • Universal hanger clip
  • Hook hanger for non magnetic surfaces
  • Strong magnet


Technical Specifications

Function Range Resolution Accuracy
AC volts 
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3
DC volts 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 3
AC millivolts 400.0 mV 0.1 mV 3.0 % + 3
DC millivolts 400.0 mV 0.1 mV 1.0 % + 10
Diode test2 2.000 V 0.001 V 0.1
Resistance 
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3
Capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency1
Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1 % + 3
Duty Cycle1 1 % to 99 % 0 1 % typical 4
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
DC current A 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
Temperature 50 °C- 400 °C
0 °C- 50 °C
-55 °C- 0 °C
0.1C 2 % ± 1 °C
± 2 °C
9 % ± 2 °C
Backlight - - Yes









































































AC And DC Voltage

Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC volts 1000 V 1 >10 MΩ <100 pF >60 dB at dc,
50 Hz or 60 Hz
-
AC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz -
DC volts 1000 V 1 >10 MΩ <100 pF >100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts 400 mV >1MΩ, <100 pF >80 dB at 50 Hz or 60 Hz -


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

Our motto "innovative solutions with technology" with this motto we provide solutions to our clients requirements.
  • Nature of Business Service Provider / Supplier / Retailer
  • Number of Employees Below 20
  • Year of Establishment 2015
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Fluke 17B Plus Digital Multimeter?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice