Why is Calibration necessary? Temperature can not be measured entirely without error, so it is necessary to quantify these errors by calibration of the probe, with or without its associated display....
View More Details
Send Enquiry

Company Information

  • Member Since 21 Years
  • Nature of Business Manufacturer
  • Year of Establishment 1993

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Why is Calibration necessary?

Temperature can not be measured entirely without error, so it is necessary to quantify these errors by calibration of the probe, with or without its associated display against the reference standard in the respective temperature range. Calibration is essential where traceability to a National Standard or International Standard in compliance to industrial requirement in ISO-9000 specification.

Labin Temperature Heating/Water/Cooling/Clinical Baths may be used for temperature application like Calibration Measurement and Comparison of the Thermometers and Associate Instruments in the given range -50 C to +300 C. An electronic proportional band control adapts the heat supplied to the bath for thermal stability and uniformity requirements of the Bath for Comparison/Calibration.


Technical Specifications

Specifications

PRS 300-H
High Temp. Oil Bath

PRS 100-H
Water Bath

PRS 20-H
Low Temp. Bath

PRS 50-H Clinical Thermometer 
Bath

Working 
Temperature Range

50 to 300oC

Amb. +5 to 100oC

-20 to Amb. oC

30 to 50oC

Resolution of Display

±0.1oC

±0.01oC

±0.1oC

±0.01oC

Overall Temp. Stability

±0.05oC

±0.02oC

±0.1oC

±0.02oC

Uniformity

±0.05oC

±0.02oC

±0.1oC

±0.02oC

Temperature Control

Microprocessor 
Based PID with RTD PT-100

Microprocessor 
Based PID with RTD PT-100

Microprocessor 
Based PID with RTD PT-100

Microprocessor 
Based PID with RTD PT-100

Heater Wattage

1000 Watt

750 Watt

750 Watt

250 Watt

PT-100 Sensor

3-Leads

3-Leads

3-Leads

3-Leads

Safety Installation

Drain Plug & Overflow Outlet for Expanded Bath Liquid

Drain Plug & Overflow Outlet for Expanded Bath Liquid

Drain Plug & Overflow Outlet for Expanded Bath Liquid

Drain Plug & Overflow Outlet for Expanded Bath Liquid

Stirrer Motor Power

1/8 hp, 1425 rpm

1/8 hp, 1425 rpm

1/8 hp, 1425 rpm

1/8 hp, 1425 rpm

Bath Opening Dia x Depth

100 x 500 mm

100 x 500 mm

150 x 500 mm

160 x 200 mm

Overall Dimension

400 x 400 x 600 mm

400 x 400 x 600 mm

450 x 450 x 600 mm

300 x 300 x 300 mm

Filling Volume

4.5 to 5.5 ltr

4.5 to 5.5 ltr

9 to 10 ltr

4.0 ltr.

Insulation - Fiber Wool & Puff

Not Less Than 135 mm

Not Less Than 135 mm

Not Less Than 135 mm

Not Less Than 100 mm

Mains Power Connections

220-240/50 V/Hz

220-240/50 V/Hz

220-240/50 V/Hz

220-240/50 V/Hz

Power Consumption

1500 Watt

850 Watt

3000 Watt

500 Watt

Permissible Ambient Temp.

10 to 35oC

10 to 35oC

10 to 35oC

10 to 27oC

 

Bath Material

S. S. 304 Grade / Powder Coating

Wall Thickness of Sheet Material

1 mm.

Insulation

Fiber Wool & Puff.

Thickness of Insulation

Not less than 135 mm.

Stirrer Type

Screw Type

Stirrer

Brass Stirrer L 400-425 mm x Ø 50 mm

Cover Plate of Bath Chamber

Hylem Sheet 19 mm thick to hold 5-6 Thermometers

 Ø of Holes in the Cover Plate

 mm 8(2), 6(2), 10(1), 12(1) other than for Control RTD and Heating Rod.

Thermometers Holding Clips

Phosphor Bronze

Stirrer Motor

¼ h.p., 1425 R.P.M., Crompton Make.

Heating System

Nichrom Heater Winding 1200 W for Low Temp. Bath and 1000 W for Water & Oil Baths with 12-5A/230V AC.

Temp. Controller

Digital PID Temp. Indicator-cum-Controller & LABIN Make Digital Temp Indicator with Display 0.01oC upto 199oC.

Temperature Sensor

RTD Pt-100, Probe Type

Level Control of Fluid

Exit Pipe will be provided for Overflow of Bath Liquid.

Frame/Stand

A Stable Wheeled Metallic Frame to hold the Bath alongwith Control Panel will be provided. Proper arrangement for Tube Light will also be provided.

Compressor

Sriram/Kirloskar Make.










Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Glass Thermometer Calibration Bath?

Quantity
Seller Contact Details
  • Seller Labin Instruments Company
  • Address Kirti Nagar, Delhi

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Glass Thermometer Calibration Bath at Best Price in Delhi - ID: 918353
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Glass Thermometer Calibration Bath

Listing ID #918353

  • Supply Type Exporter
Preferred Buyer From : All over the world

Why is Calibration necessary? Temperature can not be measured entirely without error, so it is necessary to quantify these errors by calibration of the probe, with or without its associated display....
View More Details
Send Enquiry

Company Information

  • Member Since 21 Years
  • Nature of Business Manufacturer
  • Year of Establishment 1993

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Why is Calibration necessary?

Temperature can not be measured entirely without error, so it is necessary to quantify these errors by calibration of the probe, with or without its associated display against the reference standard in the respective temperature range. Calibration is essential where traceability to a National Standard or International Standard in compliance to industrial requirement in ISO-9000 specification.

Labin Temperature Heating/Water/Cooling/Clinical Baths may be used for temperature application like Calibration Measurement and Comparison of the Thermometers and Associate Instruments in the given range -50 C to +300 C. An electronic proportional band control adapts the heat supplied to the bath for thermal stability and uniformity requirements of the Bath for Comparison/Calibration.


Technical Specifications

Specifications

PRS 300-H
High Temp. Oil Bath

PRS 100-H
Water Bath

PRS 20-H
Low Temp. Bath

PRS 50-H Clinical Thermometer 
Bath

Working 
Temperature Range

50 to 300oC

Amb. +5 to 100oC

-20 to Amb. oC

30 to 50oC

Resolution of Display

±0.1oC

±0.01oC

±0.1oC

±0.01oC

Overall Temp. Stability

±0.05oC

±0.02oC

±0.1oC

±0.02oC

Uniformity

±0.05oC

±0.02oC

±0.1oC

±0.02oC

Temperature Control

Microprocessor 
Based PID with RTD PT-100

Microprocessor 
Based PID with RTD PT-100

Microprocessor 
Based PID with RTD PT-100

Microprocessor 
Based PID with RTD PT-100

Heater Wattage

1000 Watt

750 Watt

750 Watt

250 Watt

PT-100 Sensor

3-Leads

3-Leads

3-Leads

3-Leads

Safety Installation

Drain Plug & Overflow Outlet for Expanded Bath Liquid

Drain Plug & Overflow Outlet for Expanded Bath Liquid

Drain Plug & Overflow Outlet for Expanded Bath Liquid

Drain Plug & Overflow Outlet for Expanded Bath Liquid

Stirrer Motor Power

1/8 hp, 1425 rpm

1/8 hp, 1425 rpm

1/8 hp, 1425 rpm

1/8 hp, 1425 rpm

Bath Opening Dia x Depth

100 x 500 mm

100 x 500 mm

150 x 500 mm

160 x 200 mm

Overall Dimension

400 x 400 x 600 mm

400 x 400 x 600 mm

450 x 450 x 600 mm

300 x 300 x 300 mm

Filling Volume

4.5 to 5.5 ltr

4.5 to 5.5 ltr

9 to 10 ltr

4.0 ltr.

Insulation - Fiber Wool & Puff

Not Less Than 135 mm

Not Less Than 135 mm

Not Less Than 135 mm

Not Less Than 100 mm

Mains Power Connections

220-240/50 V/Hz

220-240/50 V/Hz

220-240/50 V/Hz

220-240/50 V/Hz

Power Consumption

1500 Watt

850 Watt

3000 Watt

500 Watt

Permissible Ambient Temp.

10 to 35oC

10 to 35oC

10 to 35oC

10 to 27oC

 

Bath Material

S. S. 304 Grade / Powder Coating

Wall Thickness of Sheet Material

1 mm.

Insulation

Fiber Wool & Puff.

Thickness of Insulation

Not less than 135 mm.

Stirrer Type

Screw Type

Stirrer

Brass Stirrer L 400-425 mm x Ø 50 mm

Cover Plate of Bath Chamber

Hylem Sheet 19 mm thick to hold 5-6 Thermometers

 Ø of Holes in the Cover Plate

 mm 8(2), 6(2), 10(1), 12(1) other than for Control RTD and Heating Rod.

Thermometers Holding Clips

Phosphor Bronze

Stirrer Motor

¼ h.p., 1425 R.P.M., Crompton Make.

Heating System

Nichrom Heater Winding 1200 W for Low Temp. Bath and 1000 W for Water & Oil Baths with 12-5A/230V AC.

Temp. Controller

Digital PID Temp. Indicator-cum-Controller & LABIN Make Digital Temp Indicator with Display 0.01oC upto 199oC.

Temperature Sensor

RTD Pt-100, Probe Type

Level Control of Fluid

Exit Pipe will be provided for Overflow of Bath Liquid.

Frame/Stand

A Stable Wheeled Metallic Frame to hold the Bath alongwith Control Panel will be provided. Proper arrangement for Tube Light will also be provided.

Compressor

Sriram/Kirloskar Make.










Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Glass Thermometer Calibration Bath?

Quantity
Seller Contact Details
  • Seller Labin Instruments Company
  • Address Kirti Nagar, Delhi

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice