Contact SupplierMODEL SKY
300W 500W 10kW 50kW 100kW
Input
Power tracking window range [Vdc] 150 to 600 200 to 600 350 to 700
Max open circuit voltage [Vdc] 800 800 800
Min DC voltage for feed-in [Vdc] 1500 200 350
Max DC current [Adc] 10 20 34 120 217
Output
Nominal power rating [kW] 3.0 5.0 10 50 100
Max AC line current [Aac] 15 25 16.7 83.6 167
AC operating voltage [Vac] 1-Phase 220VAC 1-Phase 220VAC
Frequency [Hz] 50 60 Hz
Conversion efficiency [%] 98 98 94 96 97
Additional
DCAC isolation No Yes
Cooling Natural air Forced air cooled
DC reverse polarity protection Yes
Ground fault protection Integrated ground fault detectorinterrupter (GFDI)
Grounding Negative ground (optional positive ground configuration)
Visual displays Mono graphical LCD with 4 button
Included accessory interfaces RS485 Ethernet(Optional)
Ambient temperature range 0℃ - + 50℃
Thermal protection Yes
Noise emissions [dB] <45 <55 <60 <65
Relative humidity range [%] 0-90% (non condensing)
Max. altitude 1000m without de-rating
Night consumption [W] <5 <15 <30
Protective functions (Input) Over voltage, Over current, Over heat
Protective functions (Output) OverUnder voltage, OverUnder frequency, Anti-Islanding
Warranty standard 3years (Extensions available)
Hardware
Enclosure environmental rating IP65 NEMA4 IP22 NEMA3R IP22 NEMA3R
Dimensions (H, W, D) [mm] 450 X 350 X 160 1475 X 555 X 805 1800 X1 200 X 905
Weight [kg] 25 200 1100.