    POWER DISTRIBUTION UNIT WITH K-RATED TRANSFORMERS

    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world

      S.NoTechnical Specification 1 Transformer 2 Double wound , High Isolation 3 Double sized neutral 4 Insulation class 5 Regulation is better than 3.5% 6 Overload rating of 100% for 10....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 18 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

     

    S.NoTechnical Specification
    1Transformer
    2Double wound , High Isolation
    3Double sized neutral
    4Insulation class
    5Regulation is better than 3.5%
    6Overload rating of 100% for 10 secs
    7Core of CRGO and conductor of copper
    8Natural / Forced Air Cooled
    9As per IS:2026 standards
    10Attenuation – 80 db CMRR and 60 db CMNR
    11Primary connect as DELTA, secondary connection as STAR
    12Efficiency of the transformer is minimum 98% 2 Power Distribution
    13Floor mounting Panel board with MS angles and Ms sheets with powder coated Paint and suitable provisions for cable
    14Distributed outgoing through sub branch breakers and branch breakers
    15Extra sub breakers also provided
    16Suitable capacity 3 pole incomer 3 Metering & Indications
    17LED indications provided to read the availability of incoming supply
    18Multi parameter reading meter to read Voltages, currents and power is incorporated Power distribution unit is fitted with multiple outputs designed to distribute electrical power. In a data centre, all the distributed power loads are connected through a non linear power source, due to which HARMONICS generation is unavoidable. These generated Harmonics are flow back and directly effects the mains power source, which a UPS. The effect of harmonics derates the capacity of UPS. Hence 100% utilization of UPS capacity becomes wasted. The effect of harmonics also creates much heat in the transformers of UPS. To eliminate these direct effects on UPS, KFactor Transformers are designed based on the harmonics present the load. The special design of K-Factor Transformer helps us to depend on much to eliminate or withstanding from the effects of Harmonics.
      
      
      
      
      
      
      
      
      
      
      
      
      
      
      
      
      
      


    Share your requirements for a quick response!
    Tell us what you need?

    Looking for POWER DISTRIBUTION UNIT WITH K-RATED TRANSFORMERS?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice